Delta IMA-C2000-48-YV
Safety approval for Medical (IEC 60601-1-2 and 3rd+A1 edition CB report) TUV EN60601-1:2006 CAN/CSA-C22.2 NO.60601-1 + ANSI/AAMI, ES 60601-1, 3000m altidude, 100-240Vac...
Price on request
- Safety approval for Medical (IEC 60601-1-2 and 3rd+A1 edition CB report) TUV EN60601-1:2006
- CAN/CSA-C22.2 NO.60601-1 + ANSI/AAMI, ES 60601-1, 3000m altidude, 100-240Vac only
- Industrial (IEC 62368) and IT IEC60950-1 CB report, IEC62368-1 CB report, TUV EN62368-1, UL62368-1 and CAN/CSA C22.2 No. 62368-1
- 3000 Watt peak power (up to 5s)
- Standby power < 2 Watt
- Wide operating input voltage range: 80 Vac to 275 Vac or 120 Vdc to 300 Vdc
- Wide adjustable output voltage range (+/- 20%)
- Standby output 5 Vdc / 2 A
- High efficiency: up to 94%
- Size: 309.6 x 127 x 40.6 mm (12.2 x 5 x 1.6 in) (1U design)
- Low acoustic noise level of less than 39 dB(A), variable speed fan control
- Active current sharing
- 2 × MOPP and BF appliances
- PMBus™ compatible for control, programming and monitoring
- 500,000 hour MTBF
- Optional conformal coating
- 3 years warranty
Output Voltage
48V
Output Power
2000W
Output Current
41.6A
Input Voltage Range
80 - 275 Vac
Dimensions (L x W x H)
309.6 x 127 x 40.6 mm
12.19” x 5.00” x 1.60”
Unit Weight
2 kg (4.41 lb)
Similar products:
Delta IMA-C600-48-ZYPLI
Safety approval for Medical (IEC 60601-1-2), Industrial (IEC 62368) and IT Wide operating input voltage range: 80 Vac to 275 Vac or 120 Vdc to 300 Vdc Wide adjustable
-
(Out of stock)
Price on request
Delta IMA-C600-48-ZYPLY
Safety approval for Medical (IEC 60601-1-2), Industrial (IEC 62368) and IT Wide operating input voltage range: 80 Vac to 275 Vac or 120 Vdc to 300 Vdc Wide adjustable
-
(Out of stock)
Price on request
Delta IMA-S2000-48-YV
Safety approval for Medical (IEC 60601-1-2 and 3rd+A1 edition CB report) TUV EN60601-1:2006 CAN/CSA-C22.2 NO.60601-1 + ANSI/AAMI, ES 60601-1, 3000m altidude, 100-240Vac
-
(Out of stock)
Price on request
Delta IMA-C400-48-ZNPLY
Safety approval for Medical (IEC 60601-1-2), Industrial (IEC 62368) and IT Wide operating input voltage range: 80 Vac to 275 Vac or 120 Vdc to 300 Vdc Wide adjustable
-
(Out of stock)
Price on request
Delta IMA-S1000-48-YYPLI
Safety approval for Medical (IEC 60601-1-2), Industrial (IEC 62368) and IT Wide operating input voltage range: 80 Vac to 275 Vac or 120 Vdc to 300 Vdc Wide adjustable
-
(Out of stock)
36.256,72
Delta IMA-S1000-48-YYPLY
Safety approval for Medical (IEC 60601-1-2), Industrial (IEC 62368) and IT Wide operating input voltage range: 80 Vac to 275 Vac or 120 Vdc to 300 Vdc Wide adjustable
-
(Out of stock)
36.274,09