EUCHNER AR evaluation unit CES-AR-AES-12 ; 098225
AR evaluation unit CES-AR-AES-12 Central evaluation of an AR switch chain Status of each individual switch can be seen For switch chains of up to 12 devices Four...
Price on request
AR evaluation unit CES-AR-AES-12
- Central evaluation of an AR switch chain
- Status of each individual switch can be seen
- For switch chains of up to 12 devices
- Four individual safe relay contacts
- Category 4/PLe according to EN ISO 13849-1
Approvals
Mechanical values and environment
Dimensions | 114 x 99 x 45 |
Housing material | Plastic PA6.6 |
Weight | |
Net | 0,25 kg |
Ambient temperature | |
At UB = DC 24 V | -20 ... 55 °C |
Atmospheric humidity | |
Not condensing | max.80 % rH |
Degree of protection | IP20 |
Resilience to vibration | In acc. with EN 60947-5-2 |
Mounting method | Mounting rail 35 mm according to EN 60715 |
Ready delay | max.8 s |
Connection | Plug-in screw terminals coded |
Number of LED displays | 3 |
O1 ... O12 | |
Number of monitoring outputs | 12 |
Start button S | |
Manual start operating mode | |
Duration of operation of start button | min.250 ms |
Response delay start button | 300 ... 600 ms |
13/14, 23/24, 33/34, 43/44 | |
Number of safety contacts | 4 Relays with internally monitored contacts |
Mechanical life | |
Relay | 10 x 106 |
Switching frequency | 1 Hz |
Electrical connection ratings
Operating voltage DC | |
UB | 24 V DC -10% ... 10% Regulated, residual ripple < 5 % |
Current consumption | |
IB (with relay energized) | 1200 mA |
Fusing | |
External (operating voltage UB) | 2,5 ... 8 A |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 4 kV |
EMC protection requirements | In acc. with EN 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 2 |
Connection cross-section | 0,14 ... 2,5 mm² |
Switching delay from state change | max.480 ms |
Y1/Y2 | |
Current via feedback loop | 5 ... 8 ... 10 mA |
permissible resistance in feedback loop | max.600 Ω |
IA, IB | |
Number of connectible safety switches | max.12 |
Safety inputs | 2 (for CES-AR switch chain) |
13/14, 23/24, 33/34, 43/44 | |
Switching current | |
Relay outputs (at switching voltage AC/DC 21 ... 60 V | 1 ... 300 mA |
Relay outputs (at switching voltage AC/DC 5 ... 30 V) | 10 ... 6000 mA |
Relay outputs (at switching voltage AC 5 ... 230 V) | 10 ... 5000 mA |
Fusing | |
External (safety circuit) according to EN 60269-1 | 6 AgG or 6 A circuit breaker (characteristic B or C) |
Utilization category according to EN 60947-5-1 | |
AC-15 | 230 V 5 A |
DC-13 | 24 V 5 A |
AC-12 | 30 V 6 A |
60 V 0.3 A | |
DC-12 | 60 V 0.3 A |
30 V 6 A | |
Discrepancy time | |
Between the operating points of both relays | max.25 ms |
OUT AR | |
Type of output | Semiconductor output, p-switching, short circuit-proof |
Output voltage | |
HIGH | UB - 20 % ... UB V DC |
LOW | 0 ... 1 V DC |
Output current | max.20 mA |
Start button S | |
Input current | |
HIGH | 5 ... 8 ... 10 mA |
Input voltage | |
LOW | 0 ... 2 V DC |
HIGH | 15 ... UB V DC |
DIA | |
LED indicator | |
DIA | Red LED: Fault display |
Type of output | Semiconductor output, p-switching, short circuit-proof |
Output voltage | |
LOW | 0 ... 1 V DC |
HIGH | UB - 20% ... UB V DC |
Output current | max.20 mA |
O1 ... O12 | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
High | UB - 20% ... UB V DC |
LOW | 0 ... 1 V DC |
Output current | max.20 mA |
STATE | |
LED indicator | |
STATE | Green LED: Status of the device |
OUT | |
LED indicator | |
OUT | Yellow LED: State of the AR chain |
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 1.5 x 10-8 |
Number of switching cycles | |
≤ 0.1 A at 24 V DC | max.720000 1/Jahr |
≤ 1 A at 24 V DC | max.540000 1/Jahr |
≤ 3 A at 24 V DC | max.107000 1/Jahr |
Mission time | 20 y |
Similar products:
EUCHNER Transponder-coded safety switch CTA-L1-BP-U-HA-AP-SA-166702; 166702
Transponder-coded safety switch CTA-BP, M12 Safety switch with guard locking and integrated evaluation electronics Communication functions in combination with an
-
(Out of stock)
Price on request
EUCHNER Transponder-coded safety switch CTP-L1-AR-U-HA-AZ-SH-123362; 123362
Transponder-coded safety switch CTP-AR, M23 Safety switch with guard locking and integrated evaluation electronics Up to 20 switches in series Short circuit monitoring
-
(Out of stock)
Price on request
EUCHNER Transponder-coded safety switch CTM-LBI-BR-U-ZZ-V05-P-167796; 167796
Transponder-coded safety switch CTM-LBI-BR, connecting cable with flying lead Safety switch with guard locking and integrated evaluation electronics Series connection
-
(Out of stock)
Price on request
EUCHNER Actuator CET-A-BWK-50X ; 096327
Actuator CET-A-BWK-50X ; 096327 Actuator for read head/safety switch CET Four M5x16 safety screws included in scope of delivery
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switch CET3-AP-CRA-AH-50X-SA ; 122398
Non-contact safety switch CET3-AP-CRA-AH-50X-SA ; 122398 // Safety switch with guard locking and integrated evaluation electronics Locking force up to 6,500 N Short
-
(Out of stock)
Price on request
EUCHNER Transponder-coded safety switch CTP-AR, 2 x M12 , CTP-L1-AR-U-HA-AZ-SAB ; 122812
Transponder-coded safety switch CTP-AR, 2 x M12 , CTP-L1-AR-U-HA-AZ-SAB ; 122812 Safety switch with guard locking and integrated evaluation electronics Up to 20
-
(Out of stock)
Price on request