Evaluation unit CES-AZ-AES-01B (for 1 read head) ; 104770
-
1 read head can be connected
-
2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
-
Start button and feedback loop can be connected
-
Unicode
-
Plug-in connection terminals
-
Category 4 / PL e according to EN ISO 13849-1
Approvals
Workspace
Repeat accuracy R |
|
according to EN 60947-5-2 |
max. 10 % |
Operating and display elements
LED display |
|
|
Diagnostics LED |
|
Status LED |
|
Safety contacts status |
Electrical connection values
Fuse |
|
external (operating voltage UB) |
0.25 ... 8 A |
Connection cross section |
|
(plug-in screw/spring terminals) |
0.25 ... 2.5 mm² |
Operating voltage DC |
|
UB |
21 ... 24 ... 27 V DC regulated, residual ripple<5% |
EMC protection requirements |
Acc. to EN 60947-5-3 |
Current consumption |
|
(with relay energized) |
150 mA |
Current via feedback loop |
5 ... 8 ... 10 mA |
Degree of contamination (external, according to EN 60947-1) |
2 |
permissible resistance in feedback loop |
max. 600 Ω |
|
Inputs: start button S, test input TST |
Input voltage |
|
LOW |
0 ... 2 V DC |
HIGH |
15 ... UB V DC |
Input current |
|
HIGH |
5 ... 8 ... 10 mA |
|
Monitoring outputs: diagnostics DIA, door monitoring output O1 |
Output type |
Semiconductor output, p-switching, short circuit-proof |
Output voltage |
0.8 x UB ... UB V DC |
Switching current |
max. 20 mA |
|
Safety contacts 13/14, 23/24 |
Fuse |
|
external (safety circuit) according to EN 60269-1 |
6 AgG or 6 A circuit breaker (characteristic B or C) |
Output type |
Relay contacts, floating |
rated conditional short-circuit current |
100 A |
Rated insulation voltage Ui |
250 V |
Rated impulse withstand voltage Uimp |
4 kV |
Discrepancy time |
|
(between the operating points of both relays) |
max. 25 ms |
Utilization category |
|
DC-12 |
60 V 0.3 A |
AC-12 |
30 V 6 A |
AC-12 |
60 V 0.3 A |
DC-12 |
30 V 6 A |
AC-15 |
230 V 2 A |
DC-13 |
24 V 3 A |
Switching load |
|
according to c UL us |
Class 2 max. 30 V AC / Class 2 max. 60 V DC; 120 V AC 3 A / 240 V AC 1.5 A |
Switching current |
|
at switching voltage AC 5 ... 230 V |
10 ... 2000 mA |
at switching voltage AC/DC 21 ... 60 V |
1 ... 300 mA |
at switching voltage AC/DC 5 ... 30 V |
10 ... 6000 mA |
Mechanical values and environment
Connection type |
plug-in connection terminals, coded |
Number of read heads |
1 read head can be connected |
Ready delay |
10 ... 12 s |
Switching frequency |
max. 0.25 Hz |
Atmospheric humidity |
|
not condensing |
max. 80 % rH |
Mounting distance |
|
laterally to the neighboring device |
min. 10 mm |
Mounting type |
Mounting rail 35 mm according to DIN EN 60715 TH35 |
Response time |
|
Start button response delay (for Manual start operating mode) |
200 ... 300 ms |
after change in the actuation status |
max. 210 ms |
Start button actuating duration (for Manual Start operating mode) |
min. 250 ms |
Degree of protection |
IP20 |
Ambient temperature |
|
at UB = 24 V DC |
-20 ... +55 °C |
Dwell time |
min. 3 s |
Material |
|
Housing |
Plastic PA6.6 |
|
Safety contacts 13/14, 23/24 |
Number of safety contacts |
2 Relay with internally monitored contacts |
Mechanical life |
|
Operating cycles (relay) |
10 x 10⁶ |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Number of switching cycles |
|
≤ 0.1 A at 24 V DC |
max. 760000 1/y |
≤ 1 A at 24 V DC |
max. 153000 1/y |
≤ 3 A at 24 V DC |
max. 34600 1/y |
Diagnostic Coverage (DC) |
99 % |
Mission time |
20 y |
|
Monitoring of the guard position |
Category |
4 |
Performance Level |
PL e |
PFHD |
1.9 x 10-8 |
Miscellaneous
The following applies to the approval according to UL |
Operation only with UL Class 2 power supply or equivalent measure. |
In combination with read head CES-A-LSP-05V-104966, CES-A-LSP-10V-104967, CES-A-LSP-SB-104969, CES-A-LSP-15V-106271 and actuator CES-A-BSP-104970
Switch-on distance |
|
with center offset m=0 |
20 mm |
Secured switch-off distance sar |
max. 45 mm |
Secured switching distance sao |
|
with center offset m=0 |
min. 10 mm |
Switching hysteresis |
1 ... 4 mm |
In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294 and actuator CES-A-BDN-06-104730
Switch-on distance |
|
in z direction (with center offset x,y=0), in y direction (with center offset x,z=0) |
19 mm |
Secured switch-off distance sar |
|
in x or z direction |
max. 50 mm |
in y direction |
max. 100 mm |
Secured switching distance sao |
|
in z direction (with center offset x,y=0), in y direction (with center offset x,z=0) |
min. 14 mm |
Switching hysteresis |
4 mm |
In combination with read head CES-A-LQA-SC
Mounting distance |
|
neighboring read heads |
min. 80 mm |
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V
Mounting distance |
|
neighboring read heads |
min. 50 mm |
In combination with read head CES-A-LQA-SC and actuator CES-A-BBA-071840, CES-A-BCA
Switch-on distance |
|
for side approach direction (distance in x direction 8 mm) |
+/- 22 mm |
for vertical approach direction (center offset m=0) |
15 mm |
Secured switch-off distance sar |
max. 47 mm |
Secured switching distance sao |
|
for side approach direction (distance in x direction 8 mm) |
min. +/- 18 mm |
for vertical approach direction (center offset m=0) |
min. 10 mm |
Switching hysteresis |
|
for side approach direction (distance in x direction 8 mm) |
1 ... 1.8 mm |
for vertical approach direction (center offset m=0) |
2 ... 3 mm |
In combination with read head CES-A-LMN-SC and actuator CES-A-BDA-20
Switch-on distance |
|
with center offset m=0 |
9 mm A distance of s = 4 mm must be maintained for a side approach direction. |
Secured switch-off distance sar |
|
with center offset m=0 |
max. 26 mm |
Secured switching distance sao |
|
with center offset m=0 |
min. 6 mm |
Switching hysteresis |
|
with center offset m=0 |
1 ... 1.8 mm |
In combination with read head CES-A-LQA-SC and actuator CES-A-BQA
Switch-on distance |
|
for vertical approach direction (center offset m=0) |
23 mm |
for side approach direction (distance in x direction 10 mm) |
+/- 28 mm |
Secured switch-off distance sar |
max. 60 mm |
Secured switching distance sao |
|
for side approach direction (distance in x direction 10 mm) |
min. +/- 24 mm |
for vertical approach direction (center offset m=0) |
min. 16 mm |
Switching hysteresis |
|
for vertical approach direction (center offset m=0) |
2 ... 3 mm |
for side approach direction (distance in x direction 10 mm) |
1 ... 1.3 mm |
In combination with read head CES-A-LMN-SC and actuator CES-A-BDA-18-156935
Actuator distance s |
|
Minimum distance for side approach direction |
min. 3 mm |
Switch-on distance |
|
with center offset m=0 |
9 mm |
Secured switch-off distance sar |
max. 21 mm |
Secured switching distance sao |
|
with center offset m=0 |
min. 6 mm |
Switching hysteresis |
|
with center offset m=0 |
0.5 ... 1 mm |
In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294
Mounting distance |
|
neighboring read heads |
min. 160 mm |
In combination with read head CES-A-LMN-SC
Mounting distance |
|
neighboring read heads |
min. 20 mm |
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-18-156935
Actuator distance s |
|
Minimum distance for side approach direction |
min. 5 mm |
Switch-on distance |
|
with center offset m=0 |
16 mm |
Secured switch-off distance sar |
max. 32 mm |
Secured switching distance sao |
|
with center offset m=0 |
min. 10 mm |
Switching hysteresis |
|
with center offset m=0 |
0.5 ... 1.4 mm |
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-20
Actuator distance s |
|
Minimum distance for side approach direction |
min. 4 mm |
Switch-on distance |
|
with center offset m=0 |
16 mm |
Secured switch-off distance sar |
max. 33 mm |
Secured switching distance sao |
|
with center offset m=0 |
min. 11 mm |
Switching hysteresis |
0.5 ... 2 mm |
In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294 and actuator CES-A-BBN-106600
Switch-on distance |
|
in z direction (with center offset x,y=0), in y direction (with center offset x,z=0) |
15 mm |
Secured switch-off distance sar |
|
in y direction |
max. 100 mm |
in x or z direction |
max. 50 mm |
Secured switching distance sao |
|
in z direction (with center offset x,y=0), in y direction (with center offset x,z=0) |
min. 10 mm |
Switching hysteresis |
1 ... 4 mm |
In combination with read head CES-A-LMN-SC and actuator CES-A-BMB
Actuator distance s |
|
Minimum distance |
min. 1.2 mm |
Switch-on distance |
|
with center offset m=0 |
5 mm |
Secured switch-off distance sar |
max. 10 mm |
Secured switching distance sao |
|
with center offset m=0 |
min. 3.5 mm |
Switching hysteresis |
0.1 ... 0.3 mm |
In combination with read head CES-A-LMN-SC and actuator CES-A-BBA-071840
Switch-on distance |
|
with center offset m=0 |
8 mm A distance of s = 3 mm must be maintained for a side approach direction. |
Secured switch-off distance sar |
|
with center offset m=0 |
max. 25 mm |
Secured switching distance sao |
|
with center offset m=0 |
min. 5 mm |
Switching hysteresis |
|
with center offset m=0 |
1 ... 1.8 mm |
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BBA-071840, CES-A-BCA
Actuator distance s |
|
Minimum distance for side approach direction |
min. 3 mm |
Switch-on distance |
|
with center offset m=0 |
15 mm |
Secured switch-off distance sar |
max. 26 mm |
Secured switching distance sao |
|
with center offset m=0 |
min. 10 mm |
Switching hysteresis |
0.5 ... 2 mm |