EUCHNER Evaluation unit CMS-E-AR ; 099182

Evaluation unit CMS-E-ER, 2 safety contacts, 1 auxiliary contact, 1 feedback loop can be connected.. Up to 30 read heads can be connected 2 safety contacts 1 auxiliary...

Brand: EUCHNER
Product Code: 099182
Availability: Check availability
Price on request

Evaluation unit CMS-E-ER, 2 safety contacts, 1 auxiliary contact, 1 feedback loop can be connected..


  • Up to 30 read heads can be connected
  • 2 safety contacts
  • 1 auxiliary contact
  • 1 feedback loop can be connected
  • Start automatic/monitored/not monitored

Approvals

Zulassung EACZulassung c_UL_us LISTED Class 2

Mechanical values and environment

Housing material Polyamide PA6.6
Weight  
Net 0,22 kg
Ambient temperature 0 ... 55 °C
Degree of protection Terminals IP20 / housing IP40
Mechanical life 10 x 106
Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
Connection Connection terminals
  Safety contacts 13/14 and 23/24
Number of safety contacts 2
  Auxiliary contacts 31/32
Number of auxiliary contacts 1

Electrical connection ratings

Operating voltage  
AC/DC 24 V -10% ... +10% V
Fusing  
Protection internal (operating voltage UB) 0,75 A Automatically resetting fuse PTC
Rated insulation voltage Ui  
AC 250 V
Degree of contamination (external, according to EN 60947-1) 2
Connection cross-section 0,14 ... 2,5 mm²
LED indicator 1 indicator LED Power (UB) and 2 status indicators for the read heads (K1/K2)
  Safety contacts 13/14 and 23/24
Type of output Relay contacts, floating
Current consumption  
at DC 24V 10 ... 110 mA
Switching voltage max.240 V
Switching current  
at DC 24V 10 ... 3000 mA
Fusing  
External contact fuse (safety circuit) acc. to EN IEC 60269-1 4A gG
Utilization category according to EN 60947-4-1  
Utilization category according to EN 60947-5-1  
AC-15 0.9A , 240V and 0.9A , 24V
DC-13 1.5A , 24V
Switching load  
According to UL class 2 Input: 24V AC/DC ; output: 30V AC, 24V DC
Breaking capacity (VA) max.720 VA
Risk time according to EN 60947-5-3 20 ms
  Auxiliary contacts 31/32
Type of output Relay contacts, floating
Switching current  
at DC 24V max.1500 mA

Other

In compliance with EN ISO 13849-1: 2015; EN ISO 13849-2:2012; EN 50178: 1997; EN 60204-1: 2006/A1: 2009; EN ISO 13850: 2015; EN 14119:2013; EN 6100-6-2: 2005; EN 6100-6-3: 2007/A1: 2011; EN 60947-5-3: 2013

Reliability values according to EN ISO 13849-1

  Monitoring of the safety guard position
Category  
With one read head 4
With more than one read head 3
Performance Level  
With one read head PL e
With more than one read head PL d
PFHD  
With one read head 2.5 x 10-8
With more than one read head 1.0 x 10-7
Number of switching cycles  
≤ 1A at 24V DC 70000 1/Jahr
≤ 0.1A at 24V DC 166000 1/Jahr
Mission time 20 y

In combination with Read head CMS-R-BXI-03V, CMS-R-BXI-05V, CMS-R-BXI-SC, CMS-R-BXI-07P and Actuator CMS-M-BD

Operating distance

Center offset  
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.12 mm
Assured operating distance Sao  
With center offset m=0 min.3 mm

In combination with Read head CMS-R-AXH-03V, CMS-R-AXH-05V, CMS-R-AXH-SC and Actuator CMS-M-AC

Operating distance

Center offset  
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.31 mm
Assured operating distance Sao  
With center offset m=0 min.6 mm

In combination with Read head CMS-R-CXC-03V, CMS-R-CXC-05V, CMS-R-CXC-05P, CMS-R-CXC-SC and Actuator CMS-M-CA

Operating distance

Center offset  
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.14 mm
Assured operating distance Sao  
With center offset m=0 min.6 mm

In combination with Read head CMS-R-EXM-03V, CMS-R-EXM-05V, CMS-R-EXM-SC and Actuator CMS-M-EF

Operating distance

Center offset  
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.17 mm
Assured operating distance Sao  
With center offset m=0 min.6 mm

In combination with Read head CMS-RH-AYA-03VL, CMS-RH-AYA-05VL and Actuator CMS-MH-AA

Operating distance

Center offset  
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.20 mm
Assured operating distance Sao  
With center offset m=0 min.10 mm

In combination with Read head CMS-RH-BYB-03VL, CMS-RH-BYB-05VL and Actuator CMS-MH-BB

Operating distance

Center offset  
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.13 mm
Assured operating distance Sao  
With center offset m=0 min.6 mm
  • CMS-E-AR Operating instructions

    CMS-E-AR Operating instructions

  • CMS-E-AR Safety Information

    CMS-E-AR Safety Information



Similar products:


EUCHNER Evaluation unit CMS-E-AR ; 085536

Evaluation unit CMS-E-AR, 1 safety contact Magnetically coded safety switches are interlocking devices that are designed to protect people and machines. Compared
-
Need to order

(Out of stock)

Price on request

EUCHNER Evaluation unit CMS-E-AR ; 085537

Evaluation unit CMS-E-BR, 1 safety contact, 1 auxiliary contact, 1 feedback loop can be connected.. Four read heads can be connected 1 safety contact 1 auxiliary
-
Need to order

(Out of stock)

Price on request

EUCHNER Evaluation unit CMS-E-AR ; 099258

Evaluation unit CMS-E-FR, 2 safety contacts, 1 auxiliary contact, 6 monitoring outputs, 1 feedback loop can be connected.. Up to 30 read heads can be connected 2
-
Need to order

(Out of stock)

Price on request

EUCHNER CMS-M-AI Actuator CMS design A; 093976

Cube-shaped version, 88 x 25 mm
-
Need to order

(Out of stock)

Price on request

EUCHNER Read Heads CMS ; CMS-R-AZA-01PL-AS1 ; 105090

Non-contact safety switch CMS-R-AZA-01VL-AS1, with connection cable and plug connector M12. Safety switches with integrated read head and integrated evaluation unit.
-
Need to order

(Out of stock)

Price on request

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products