EUCHNER Interlocking module MGB-L0-ARA-AA1A1-M-105331; 105331
Interlocking module MGB-L0-ARA..., without control or indicator Interlocking (without guard locking) Can be connected in series with other AR devices (e.g. CES-AR...
Price on request
Interlocking module MGB-L0-ARA..., without control or indicator
- Interlocking (without guard locking)
- Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
- With cable entry
- Unicode
Approvals
Operating and display elements
Occupancy diagram | L0 |
Electrical connection values
Connection cross section | |
(rigid/flexible) | 0.13 ... 1.5 mm² |
(rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0.25 ... 1.5 mm² |
(rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0.25 ... 0.75 mm² |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Discrepancy time | |
between FO1A and FO1B | max. 10 ms |
Utilization category | |
DC-13 | 24V 200mA |
Risk time according to EN 60947-5-3 | max. 350 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 5 ms |
Safety class | III |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring outputs OD, OT, OL, OI | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max. 50 mA |
Safety outputs FO1A, FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
Output current | |
per safety output FO1A / FO1B | 1 ... 200 mA |
Test pulse duration | max. 1 ms |
Test pulse interval | min. 100 ms |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... +10% |
Current consumption | |
IUA | max. 10 mA |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... +10% |
Current consumption | |
IUB | max. 80 mA |
Mechanical values and environment
Connection type | Cable entries M20x1.5 |
Installation orientation | any |
Switching frequency | 0.25 Hz |
Mechanical life | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
1 x 10⁶ | |
Degree of protection | IP65 |
Ambient temperature | |
at UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Monitoring of the guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Miscellaneous
Product version number | V4.0.0 |
Similar products:
EUCHNER Interlocking module MGB-L0-ARA-AM3A1-M-R-121253; 121253
Interlocking module MGB-L0-ARA..., with 2 pushbuttons, emergency stop, incl. label carrier Interlocking (without guard locking) Can be connected in series with other
-
(Out of stock)
Price on request
EUCHNER Interlocking set MGB-L0H-ARA-L-121260; 121260
Interlocking set MGB-L0H-ARA..., with 2 pushbuttons, emergency stop, incl. label carrier Interlocking (without guard locking) Can be connected in series with other
-
(Out of stock)
Price on request
EUCHNER Interlocking set MGB-L0H-ARA-R-105778; 105778
Interlocking set MGB-L0H-ARA..., without controls or indicators Interlocking (without guard locking) Can be connected in series with other AR devices (e.g. CES-AR
-
(Out of stock)
Price on request
EUCHNER Interlocking set MGB-L0HE-ARA-R-105780; 105780
Interlocking set MGB-L0HE-ARA..., without controls or indicators Interlocking (without guard locking) Can be connected in series with other AR devices (e.g. CES-AR
-
(Out of stock)
Price on request
EUCHNER Interlocking set MGB-L0HE-ARA-R-121233; 121233
Interlocking set MGB-L0HE-ARA..., with 2 pushbuttons, emergency stop Interlocking (without guard locking) Can be connected in series with other AR devices (e.g.
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L1-ARA-AA1A1-M-104302; 104302
Locking module MGB-L1-ARA... (guard locking by spring force) without controls or indicators Guard locking with guard lock monitoring Can be connected in series with
-
(Out of stock)
Price on request