EUCHNER Locking module MGB-L1-APA-AH3A1-S1-L-115896; 115896

EUCHNER Locking module MGB-L1-APA-AH3A1-S1-L-115896; 115896

Locking module MGB-L1-APA... (guard locking by spring force) with 1 pushbutton, 1 indicator, emergency stop, RC18 Guard locking with guard lock monitoring Emergency...

Brand: EUCHNER
Product Code: 115896
Availability: Check availability
Price on request

Locking module MGB-L1-APA... (guard locking by spring force) with 1 pushbutton, 1 indicator, emergency stop, RC18

  • Guard locking with guard lock monitoring
  • Emergency stop according to ISO 13850
  • 1 indicator (illuminated, gn)
  • 1 pushbutton (illuminated, rd)
  • With plug connector RC18
  • Unicode

Approvals

c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20FCC_2AJ58-09_

Operating and display elements

Occupancy diagram L1
Item Extras Color Designation1 Number LED Note slide-in label Slide-in label Version Switching element
1 with monitoring contact             Emergency stop 2 PD + 1 NO
2   Green           Cover for indicators  
3   Red           Illuminated pushbutton 1NO

Electrical connection values

Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1.5 kV
Discrepancy time  
between FO1A and FO1B max. 10 ms
Utilization category  
DC-13 24V 200mA 
Risk time according to EN 60947-5-3 max. 350 ms
Safety class III
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
  Solenoid control input IMP1, IMP2, IMM
Test pulse duration max. 5 ms
Test pulse interval min. 100 ms
  Controls and indicators
Breaking capacity max. 0.25 W
Switching voltage UA V
Switching current 1 ... 10 mA
LED power supply 24 V DC
  Emergency stop
Breaking capacity max. 0.25 W
Switching voltage 5 ... 24 V
Switching current 1 ... 100 mA
LED power supply 24 V DC
  Monitoring outputs OD, OT, OL, OI
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC 
Output current max. 50 mA
  Safety outputs FO1A, FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage  
UFO1A /UFO1B HIGH UB-2V ... UB V DC 
UFO1A /UFO1B LOW 0 ... 1 V DC
Output current  
per safety output FO1A / FO1B 1 ... 200 mA
Test pulse duration max. 0.3 ms
Test pulse interval min. 100 ms
  Power supply UA
Operating voltage DC  
UA 24 V DC -15% ... +10% 
Current consumption  
IUA max. 375 mA 
  Power supply UB
Operating voltage DC  
UB 24 V DC -15% ... +10% 
Current consumption  
IUB max. 80 mA 

Mechanical values and environment

Connection type Plug connector RC18 
Installation orientation Door hinge DIN left
Switching frequency 0.25 Hz
Mechanical life  
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
  1 x 10⁶
Degree of protection IP65
Ambient temperature  
at UB = 24 V DC -20 ... +55 °C
Material  
Housing Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel
Locking force FZh 2000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Similar products:


EUCHNER Interlocking set MGB-L0HE-ARA-L-111942; 111942

Interlocking set MGB-L0HE-ARA... without controls or indicators, RC18 Interlocking (without guard locking) Can be connected in series with other AR devices (e.g.
-
Need to order

(Out of stock)

Price on request

EUCHNER Interlocking module MGB-L0-APA-AA1A2-S1-L-112598 ; 112598

Interlocking module MGB-L0-APA..., without controls or indicators, RC18, on mounting plates Interlocking (without guard locking) With plug connector RC18 Mounted
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L1H-APA-L-117069; 117069

Locking set MGB-L1H-APA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. adhesive labels, RC18 Guard locking with guard lock monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L2H-APA-L-115674; 115674

Locking set MGB-L2H-APA... (guard locking by solenoid force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-
Need to order

(Out of stock)

Price on request

EUCHNER Interlocking set MGB-L0HE-ARA-L-110692; 110692

Interlocking set MGB-L0HE-ARA..., with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Interlocking (without guard locking) Can be connected in series with
-
Need to order

(Out of stock)

Price on request

EUCHNER Interlocking set MGB-L0HE-APA-L-112602; 112602

Interlocking set MGB-L0HE-APA..., without controls or indicators, RC18, on mounting plates Locking (without guard locking) With plug connector RC18 Mounted on mounting
-
Need to order

(Out of stock)

Price on request

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products
Mission time 20 y
  Control of guard locking
Category 4
Performance Level PL e
PFHD 2.8 x 10-9