EUCHNER Locking module MGB-L1-APA-AP4A1-S1-R-158117; 158117
Locking module MGB-L1-APA.. (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according...
Price on request
Locking module MGB-L1-APA.. (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850
- 3 pushbuttons (illuminated)
- With lens set, 6 pcs.
- With plug connector RC18
- Unicode
Approvals
Operating and display elements
Occupancy diagram | L1 |
Item | Extras | Color | Designation1 | Number | LED | Note slide-in label | Switching element | Slide-in label | Version |
---|---|---|---|---|---|---|---|---|---|
1 | 2 PD | Emergency stop | |||||||
2 | 1NO | Illuminated pushbutton | |||||||
3 | 1NO | Illuminated pushbutton | |||||||
4 | 1NO | Illuminated pushbutton |
Electrical connection values
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Discrepancy time | |
between FO1A and FO1B | max. 10 ms |
Utilization category | |
DC-13 | 24V 200mA |
Risk time according to EN 60947-5-3 | max. 350 ms |
Safety class | III |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Solenoid control input IMP1, IMP2, IMM | |
Test pulse duration | max. 5 ms |
Test pulse interval | min. 100 ms |
Controls and indicators | |
Breaking capacity | max. 0.25 W |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
LED power supply | 24 V DC |
Emergency stop | |
Breaking capacity | max. 0.25 W |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
LED power supply | 24 V DC |
Monitoring outputs OD, OT, OL, OI | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max. 50 mA |
Safety outputs FO1A, FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
Output current | |
per safety output FO1A / FO1B | 1 ... 200 mA |
Test pulse duration | max. 0.3 ms |
Test pulse interval | min. 100 ms |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... +10% |
Current consumption | |
IUA | max. 375 mA |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... +10% |
Current consumption | |
IUB | max. 80 mA |
Mechanical values and environment
Connection type | Plug connector RC18 |
Installation orientation | Door hinge DIN right |
Switching frequency | 0.25 Hz |
Mechanical life | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
1 x 10⁶ | |
Degree of protection | IP65 |
Ambient temperature | |
at UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel |
Locking force FZh | 2000 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Control of guard locking | |
Category |
Similar products:
EUCHNER Locking module MGB-L1-APA-AA1A2-S1-R-112597; 112597
Locking module MGB-L1-APA... (guard locking by spring force) without controls or indicators, RC18, on mounting plates Guard locking with guard lock monitoring With
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L1-APA-AP4A1-S1-R-121368; 121368
Locking module MGB-L1-APA.. (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L1-APA-AP5A1-S1-R-121376; 121376
Locking module MGB-L1-APA.. (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-
(Out of stock)
Price on request
EUCHNER Locking set MGB-L1H-APA-R-115671; 115671
Locking set MGB-L1H-APA... (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-
(Out of stock)
Price on request
EUCHNER Locking set MGB-L1H-APA-R-115895; 115895
Locking set MGB-L1H-APA... (guard locking by spring force) with 1 pushbutton, 1 indicator, emergency stop, RC18 Guard locking with guard lock monitoring Emergency
-
(Out of stock)
Price on request
EUCHNER Locking set MGB-L2H-APA-R-115673; 115673
Locking set MGB-L2H-APA... (guard locking by solenoid force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-
(Out of stock)
Price on request