EUCHNER Locking set MGB-L1H-ARA-R-105782; 105782

EUCHNER Locking set MGB-L1H-ARA-R-105782; 105782

Locking set MGB-L1H-ARA... (guard locking by spring force) without control or indicator Guard locking with guard lock monitoring Can be connected in series with...

Brand: EUCHNER
Product Code: 105782
Availability: Check availability
Price on request

Locking set MGB-L1H-ARA... (guard locking by spring force) without control or indicator

  • Guard locking with guard lock monitoring
  • Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
  • With cable entry
  • Unicode

Approvals

c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20FCC_2AJ58-09_

Handle modules MGB-H-AA1A1-R-100464 (Order no. 100464)

Handle modules MGB-H-AA1A1-R-100464  (Order no. 100464)

Mechanical values and environment

Installation orientation Door hinge DIN right
Degree of protection IP65
Ambient temperature -20 ... +55 °C
Material  
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Miscellaneous

Product version number V3.0.0

Locking modules MGB-L1-ARA-AA1A1-M-104302 (Order no. 104302)

Locking modules MGB-L1-ARA-AA1A1-M-104302  (Order no. 104302)

Operating and display elements

Occupancy diagram L0

Electrical connection values

Connection cross section  
(rigid/flexible) with cable end sleeve according to DIN 46 228/1 0.25 ... 1.5 mm²
(rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 0.25 ... 0.75 mm²
(rigid/flexible) 0.13 ... 1.5 mm² 
Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1.5 kV
Discrepancy time  
between FO1A and FO1B max. 10 ms
Utilization category  
DC-13 24V 200mA 
Risk time according to EN 60947-5-3 max. 350 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Safety class III
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
  Solenoid control input IMP1, IMP2, IMM
Test pulse duration max. 5 ms
Test pulse interval min. 100 ms
  Monitoring outputs OD, OT, OL, OI
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC 
Output current max. 50 mA
  Safety outputs FO1A, FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage  
UFO1A /UFO1B LOW 0 ... 1 V DC
UFO1A /UFO1B HIGH UB-2V ... UB V DC 
Output current  
per safety output FO1A / FO1B 1 ... 200 mA
Test pulse duration max. 1 ms
Test pulse interval min. 100 ms
  Power supply UA
Operating voltage DC  
UA 24 V DC -15% ... +10% 
Current consumption  
IUA max. 375 mA 
  Power supply UB
Operating voltage DC  
UB 24 V DC -15% ... +10% 
Current consumption  
IUB max. 80 mA 

Mechanical values and environment

Connection type Cable entries M20x1.5
Installation orientation any
Switching frequency 0.25 Hz
Mechanical life  
  1 x 10⁶
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
Degree of protection IP65
Ambient temperature  
at UB = 24 V DC -20 ... +55 °C
Material  
Gehäuse Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel
Locking force FZh 2000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
  Control of guard locking
Category 4
Performance Level PL e
PFHD 2.8 x 10-9
  Monitoring of guard locking and the guard position
Category 4
Performance Level PL e
PFHD 3.7 x 10-9

Miscellaneous

Product version number V4.0.0

Similar products:


EUCHNER Locking module MGB-L1-ARA-AA1A1-M-104302; 104302

Locking module MGB-L1-ARA... (guard locking by spring force) without controls or indicators Guard locking with guard lock monitoring Can be connected in series with
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L1HE-ARA-R-105784; 105784

Locking set MGB-L1HE-ARA... (guard locking by spring force) without control or indicator Guard locking with guard lock monitoring Can be connected in series with
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking module MGB-L2-ARA-AA1A1-M-104303; 104303

Locking module MGB-L2-ARA... (guard locking by solenoid force) without controls or indicators Guard locking with guard lock monitoring Can be connected in series
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L2HE-ARA-R-109946; 109946

Locking set MGB-L2HE-ARA..., (guard locking by solenoid force) without control or indicator, guard lock monitoring switched off Guard locking with guard lock monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L2H-ARA-R-105786; 105786

Locking set MGB-L2H-ARA... (guard locking by solenoid force) without control or indicator Guard locking with guard lock monitoring Can be connected in series with
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L2HE-ARA-R-105788; 105788

Locking set MGB-L2HE-ARA... (guard locking by solenoid force) without control or indicator Guard locking with guard lock monitoring Can be connected in series with
-
Need to order

(Out of stock)

Price on request

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products