EUCHNER Locking set MGB-L1HE-APA-L-156003; 156003
Locking set MGB-L1HE-APA..., (guard locking by spring force) with 3 pushbuttons, 2 x M12 Guard locking with guard lock monitoring 3 pushbuttons (illuminated, bu...
Price on request
Locking set MGB-L1HE-APA..., (guard locking by spring force) with 3 pushbuttons, 2 x M12
- Guard locking with guard lock monitoring
- 3 pushbuttons (illuminated, bu wh, wh)
- With plug connector M12, 5-pin
- With plug connector M12, 8-pin
- With escape release
- Unicode
- Connection for Bihl-Wiedemann modules BW 3376 and BW 3377
Approvals
Escape release MGB-E-A-100465 (Order no. 100465)
Mechanical values and environment
Installation orientation | any |
Mechanical life | 1 x 10⁶ |
Ambient temperature | -25 ... +55 °C |
Material | |
Housing | Die-cast zinc/stainless steel, powder-coated |
Miscellaneous
Product version number | V2.0.0 |
Handle modules MGB-H-AA1A1-L-106619 (Order no. 106619)
Mechanical values and environment
Installation orientation | Door hinge DIN left |
Degree of protection | IP65 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Miscellaneous
Product version number | V3.0.0 |
Locking modules MGB-L1-APA-AD3A1-S9-L-156001 (Order no. 156001)
Operating and display elements
Occupancy diagram | L1 |
Item | Extras | Color | Designation1 | Number | LED | Note slide-in label | Switching element | Slide-in label | Version |
---|---|---|---|---|---|---|---|---|---|
1 | Blue | 1NO | Illuminated pushbutton | ||||||
2 | printed | white | 1NO | Illuminated pushbutton | |||||
3 | printed | white | 1NO | Illuminated pushbutton |
Electrical connection values
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Discrepancy time | |
between FO1A and FO1B | max. 10 ms |
Utilization category | |
DC-13 | 24V 200mA |
Risk time according to EN 60947-5-3 | max. 350 ms |
Safety class | III |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Solenoid control input IMP1, IMP2, IMM | |
Test pulse duration | max. 5 ms |
Test pulse interval | min. 100 ms |
Controls and indicators | |
Breaking capacity | max. 0.25 W |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
LED power supply | 24 V DC |
Monitoring outputs OD, OT, OL, OI | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max. 50 mA |
Safety outputs FO1A, FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
Output current | |
per safety output FO1A / FO1B | 1 ... 200 mA |
Test pulse duration | max. 0.3 ms |
Test pulse interval | min. 100 ms |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... +10% |
Current consumption | |
IUA | max. 375 mA |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... +10% |
Current consumption | |
IUB | max. 80 mA |
Mechanical values and environment
Connection type | |
Plug connector SM5 | |
Plug connector SM8 | |
Installation orientation |