EUCHNER Locking set MGB-L2...-PN (guard locking by solenoid force) with 5 buttons, 7/8'' and M12 plugs, MGB-L2HEB-PNA-R-161483
Guard locking with guard lock monitoring Emergency stop according to ISO 13850, illuminated 4 illuminated pushbuttons including adhesive labels Connection via 7/8"...
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850, illuminated
- 4 illuminated pushbuttons
- including adhesive labels
- Connection via 7/8" and M12 plugs
- including terminal plug for stack light (M12, 5-pin)
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
- With escape release
- Unicode
Profinet connection
7/8" plugs according to ANSI/B93.55M-1981 and M12 plugs (d-coded) according to IEC 61076-2-101
Profinet RT switch
Point-to-point topology network structure due to integrated RT switch.
Flexible use as interlocking or guard locking
By means of the corresponding evaluation of the safe device data by the control system, use can be as either interlocking or guard locking (with or without monitoring).
Illuminated emergency stop
Emergency stop with illumination that can be controlled as required.
Escape release
The escape release enables people accidentally shut in to open the guard locked door from the danger zone.
Approvals
Handle modules MGB-H-AA1A2-R-106049 (Order no. 106049)
Mechanical values and environment
Installation orientation | Door hinge DIN right |
Degree of protection | IP65 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Miscellaneous
Product version number | V3.0.0 |
Additional feature | with mounting plate |
Escape release MGB-E-A2-106051 (Order no. 106051)
Mechanical values and environment
Installation orientation | any |
Mechanical life | 1 x 10⁶ |
Ambient temperature | -30 ... +55 °C |
Material | |
Housing | Die-cast zinc/stainless steel, powder-coated |
Miscellaneous
Product version number | V2.0.0 |
Additional feature | with mounting plate |
Locking modules MGB-L2B-PNA-R-161481 (Order no. 161481)
Workspace
Secured switch-off distance sar | |
Door position | max. 65 mm |
Operating and display elements
Occupancy diagram | |
B1 | |
L1 |
Item | Color | Extras | Version | Slide-in label | Note slide-in label | Switching element | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
1 | Emergency stop illuminated | 2 PD | |||||||
90 | Red | Illuminated pushbutton | 1NO | ||||||
92 | Green | Illuminated pushbutton | 1NO | ||||||
93 | Yellow | Illuminated pushbutton | 1NO | ||||||
95 | Green | Pushbutton | 1NO |
Electrical connection values
Connecting cable | |
Ethernet | Profinet I/O cable, at least cat. 5e |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
maximum feed-in current in the connection block | |
X1, X2 | max. 4000 mA |
Safety class | III |
Current consumption | max. 500 mA |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Power supply X1 | |
Fuse | |
external | min. 1 A slow blow |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% |
Mechanical values and environment
Connection type | |
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12, D-coded, screened |
7/8" Power | |
7/8" Power | |
Plug connector M12 | |
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12, D-coded, screened |
Installation orientation | Door hinge DIN right |
Switching frequency | 0.25 Hz |
Mechanical life | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
1 x 10⁶ | |
Response time | |
Door position | max. 550 ms Turn-off time |
Bolt position | max. 550 ms Turn-off time |
Guard locking | max. 550 ms Turn-off time |
Emergency stop / machine stop | max. 250 ms Turn-off time |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP54 |
Ambient temperature | |
at UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Locking force FZh | 2000 N |
Guard locking principle | Open-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Safety Integrity Level | SIL 3 (EN 62061:2005) |
Control of guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.91 x 10-8 |
Emergency stop | |
B10D | |
Emergency stop | 0.13 x 10⁶ |
Emergency-stop evaluation | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-8 |
Monitoring of guard locking and the guard position | |
Diagnostic Coverage (DC) | 99 % |
Category | 4 |
Performance Level | PL e |
PFHD | 4.07 x 10-8 |
Miscellaneous
Slide-in label | |||||||
|
|||||||
Product version number | V3.30.10 |
Interface
Bus data protocol | Profinet (IEC 61158 type 10) |
Safety data protocol | Profisafe (IEC 61784-3-3) |
Date interface | |
Ethernet |
Similar products:
EUCHNER Interlocking set MGB-L0H-APA-R-110550; 110550
(Out of stock)
EUCHNER Handle module MGB-H-AA1A1-R-100464; 100464
(Out of stock)
EUCHNER Locking module MGB-L1-APA-AP4A1-M-R-137326; 137326
(Out of stock)
EUCHNER Interlocking module MGB-L0-ARA-AA1A1-S1-R-110950; 110950
(Out of stock)
EUCHNER Interlocking set MGB-L0H-ARA-R-105779; 105779
(Out of stock)
EUCHNER Interlocking set MGB-L0HE-ARA-R-121233; 121233
(Out of stock)