EUCHNER Non-contact safety switch CES-A-C5E-01; 077750
Non-contact safety switch CES-A-C5... Safety switch with integrated evaluation electronics Pulsed signals can be switched 2 safety outputs (semiconductor outputs)...
Price on request
Non-contact safety switch CES-A-C5...
- Safety switch with integrated evaluation electronics
- Pulsed signals can be switched
- 2 safety outputs (semiconductor outputs)
- Category 3 / PL e according to EN ISO 13849-1
- Unicode
Approvals
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | max. 10 % |
Operating and display elements
LED display | |
Safety outputs status / diagnostics LED (combined) | |
Status LED |
Electrical connection values
Fuse | |
(external) operating voltage | 0.25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | 18 ... 24 ... 27 V DC regulated, residual ripple<5% |
EMC protection requirements | Acc. to EN 60947-5-3 |
Current consumption | 80 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output OUT | |
Output type | Semiconductor output, p-switching, short circuit-proof |
Output voltage | 0.8 x UB ... UB V DC |
Switching current | max. 20 mA |
Safety outputs LA / LB | |
Fuse | |
external, safety circuit U(+LA) / U(+LB) | 0.4 A medium slow-blow |
Output type | Semiconductor outputs, p-switching, short circuit-proof, electrically decoupled |
Output voltage | |
HIGH U(LA) | U(+LA) - 1.5 ... U(+LA) V DC |
LOW U(LA) / U(LB) | 0 ... 1 V DC |
HIGH U(LB) | U(+LB) - 1.5 ... U(+LB) V DC |
Output current | |
per safety output | |
rated conditional short-circuit current | max. 100 A |
Discrepancy time | |
(between the operating points of both safety outputs) | max. 120 ms |
Utilization category | |
DC-13 Safety outputs LA / LB | 24 V 400 mA |
Switching load | |
according to UL | max. DC 24 V, Class 2 |
Switching current | |
per safety output | 1 ... 400 mA |
Power supply output load | |
U(+LA) / U(+LB) | 18 ... 24 ... 27 V DC |
Mechanical values and environment
Dimensions | according to EN 60947-5-2: (LxWxH) 131x40x40 |
Connection type | M12 plug connector, 8-pin; shield can be connected |
Tightening torque | |
Fixing screws, housing | max. 1 Nm |
Screws, read head mounting bracket | max. 0.6 Nm |
Ready delay | max. 3 s |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Mounting distance | |
between 2 switches or 2 actuators | min. 80 mm |
Response time | |
after change in the actuation status | max. 180 ms |
Degree of protection | IP65/IP67 |
Ambient temperature | |
at UB = 24 V DC | -20 ... +55 °C |
Dwell time | min. 0.5 s |
Material | |
Housing | Plastic, PBT |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL e | - | 4.29x10-8 | 3 | 20 y |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures |
In combination with actuator CES-A-BDA-20
Actuator distance s | |
Minimum distance for side approach direction | min. 5 mm |
Switch-on distance | |
with center offset m=0 | 21 mm |
Secured switch-off distance sar | max. 41 mm |
Secured switching distance sao | |
with center offset m=0 | min. 19 mm |
Switching hysteresis | 2 ... 3 mm |
In combination with actuator CES-A-BBA-071840, CES-A-BCA
Actuator distance s | |
Minimum distance for side approach direction | min. 4 mm |
Switch-on distance | |
with center offset m=0 | 20 mm |
Secured switch-off distance sar | max. 40 mm |
Secured switching distance sao | |
with center offset m=0 | min. 18 mm |
Switching hysteresis | 2 ... 3 mm |
In combination with actuator CES-A-BPA-098775
Similar products:
EUCHNER Non-contact safety switch CES-A-C5H-01; 091458
Non-contact safety switch CES-A-C5... Safety switch with integrated evaluation electronics Pulsed signals can be switched 2 safety outputs (semiconductor outputs)
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switch CES-A-C5H-01-EX; 097945
Non-contact safety switch CES-A-C5... ATEX ATEX version With protective plate Suitable for use in zones 2 and 22 (gases and dusts) Safety switches as interlocking
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switch CES-A-W5H-01; 097525
Non-contact safety switch CES-A-W5... Safety switch with integrated evaluation electronics Pulsed signals can be switched 2 safety outputs (semiconductor outputs)
-
(Out of stock)
Price on request
EUCHNER Actuator CES-A-BLN-U2-103450 (Order no. 103450)
Actuator CES-A-BLN-U... Cube-shaped design 55 x 30 mm Use independent of position of door hinge Reinforcement plates Two safety screws M4x14 included
-
(Out of stock)
0,00
EUCHNER Actuator CES-A-BBN-106600; 106600
EUCHNER Actuator CES-A-BBN-106600; 106600 // Cube-shaped design 42 x 25 mm Mounting compatible with actuator CES-A-BBA/BCA
-
(Out of stock)
Price on request
EUCHNER Actuator CES-A-BBN-C04; 115271
EUCHNER Actuator CES-A-BBN-C04; 115271 Cube-shaped design 42 x 25 mm Two safety screws M4x20 and rubber support included
-
(Out of stock)
Price on request