  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • M12 plug connector 5-pin
  • Multicode

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E346349_1/1

Workspace

Repeat accuracy R  
according to EN 60947-5-2 <=10

Electrical connection values

Fuse  
external (operating voltage) 0.25 ... 8 A
Rated insulation voltage Ui 300 V 
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC  
UB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
Turn-on time  
Safety outputs max. 400 ms
EMC protection requirements Acc. to EN IEC 60947-5-3
Risk time according to EN 60947-5-3 max. 260 ms
Safety class III
Current consumption  
no load on outputs max. 50 mA
Degree of contamination (external, according to EN 60947-1) 3
  Monitoring output DIA
Output type p-switching, short circuit-proof
Output voltage 0.8 x UB ... UB V DC 
Switching current max. 200 mA
  Safety outputs OA / OB
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage  
HIGH U(OA,OB) UB-1.5 ... UB V DC 
LOW U(OA,OB) 0 ... 1 V DC
rated conditional short-circuit current max. 100 A
Discrepancy time max. 10 ms
Utilization category  
DC-13 24 V 400 mA 
Off-state current Ir max. 0.25 mA
Switching current  
per safety output 1 ... 400 mA
Test pulse duration max. 0.4 ms

Mechanical values and environment

Connection type M12 plug connector, 5-pin
Tightening torque  
Fixing screws max. 1 Nm
Ready delay 0.5 s
Installation orientation any
Switching frequency max. 1 Hz
Mounting distance min. 40 mm
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67
Ambient temperature -20 ... +55 °C
Material  
Housing Plastic, PBT

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

  PL Maximum SIL PFHD Category Mission time
Monitoring of the guard position PL e - 2.1x10-9 4 20 y

 

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BRN-100251

Switch-on distance 27 mm
Secured switch-off distance sar max. 75 mm
Secured switching distance sao min. 20 mm 
Mounting distance  
Switching hysteresis 3 mm 

In combination with actuator CES-A-BPA-098775

Switch-on distance 22 mm 
Secured switch-off distance sar max. 58 mm
Secured switching distance sao min. 18 mm
Mounting distance  
Switching hysteresis 1 ... 2 mm

In combination with actuator CES-A-BDA-18-156935

Switch-on distance 19 mm 
Secured switch-off distance sar max. 45 mm 
Secured switching distance sao min. 10 mm 
Mounting distance  
Switching hysteresis 1 ... 3 mm 

In combination with actuator CES-A-BBA-071840

Switch-on distance 18 mm
Secured switch-off distance sar max. 45 mm 
Secured switching distance sao min. 15 mm 
Mounting distance  
Switching hysteresis 1 ... 3 mm

Similar products:


EUCHNER Non-contact safety switch CES-AP-CR2-CH-SF-100775; 100775

Non-contact safety switch CES-AP-CR2-... , with latching connection Safety switch with integrated evaluation electronics No series connection Short circuit monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switches CES-I-AP-M-C04-SK-117325; 117325

Non-contact safety switches CES-I-AP-.-C04-…, M8 Safety switch with integrated evaluation electronics No series connection Short circuit monitoring 2 safety
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switches CES-I-AP-M-C04-U05-117328; 117328

Non-contact safety switches CES-I-AP-.- C04-…, flying lead Safety switch with integrated evaluation electronics No series connection Short circuit monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CES-AP-CL2-CH-L10-106190; 106190

Non-contact safety switch CES-AP-CL2-..., flying lead, PVC Safety switch with integrated evaluation electronics No series connection Short circuit monitoring 2 safety
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CES-AP-CL2-CH-L20-106194; 106194

Non-contact safety switch CES-AP-CL2-..., flying lead, PVC Safety switch with integrated evaluation electronics No series connection Short circuit monitoring 2 safety
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CES-AP-CL2-CH-SB-106551; 106551

Non-contact safety switch CES-AP-CL2-... , M12, PUR Safety switch with integrated evaluation electronics No series connection Short circuit monitoring 2 safety outputs
-
Need to order

(Out of stock)

Price on request

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products