EUCHNER Non-contact safety switch CES-AP-C01-CH-SB-106798; 106798
Non-contact safety switch CES-AP-C01-... Safety switch with integrated evaluation electronics No series connection Short circuit monitoring 2 safety outputs (semiconductor...
Price on request
Non-contact safety switch CES-AP-C01-...
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- M12 plug connector 5-pin
- Multicode
Approvals
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | <=10 |
Electrical connection values
Fuse | |
external (operating voltage) | 0.25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
Turn-on time | |
Safety outputs | max. 400 ms |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Risk time according to EN 60947-5-3 | max. 260 ms |
Safety class | III |
Current consumption | |
no load on outputs | max. 50 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output DIA | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8 x UB ... UB V DC |
Switching current | max. 200 mA |
Safety outputs OA / OB | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
HIGH U(OA,OB) | UB-1.5 ... UB V DC |
LOW U(OA,OB) | 0 ... 1 V DC |
rated conditional short-circuit current | max. 100 A |
Discrepancy time | max. 10 ms |
Utilization category | |
DC-13 | 24 V 400 mA |
Off-state current Ir | max. 0.25 mA |
Switching current | |
per safety output | 1 ... 400 mA |
Test pulse duration | max. 0.4 ms |
Mechanical values and environment
Connection type | M12 plug connector, 5-pin |
Tightening torque | |
Fixing screws | max. 1 Nm |
Ready delay | 0.5 s |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Mounting distance | min. 40 mm |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Plastic, PBT |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL e | - | 2.1x10-9 | 4 | 20 y |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures |
In combination with actuator CES-A-BRN-100251
Switch-on distance | 27 mm |
Secured switch-off distance sar | max. 75 mm |
Secured switching distance sao | min. 20 mm |
Mounting distance | |
Switching hysteresis | 3 mm |
In combination with actuator CES-A-BPA-098775
Switch-on distance | 22 mm |
Secured switch-off distance sar | max. 58 mm |
Secured switching distance sao | min. 18 mm |
Mounting distance | |
Switching hysteresis | 1 ... 2 mm |
In combination with actuator CES-A-BDA-18-156935
Switch-on distance | 19 mm |
Secured switch-off distance sar | max. 45 mm |
Secured switching distance sao | min. 10 mm |
Mounting distance | |
Switching hysteresis | 1 ... 3 mm |
In combination with actuator CES-A-BBA-071840
Switch-on distance | 18 mm |
Secured switch-off distance sar | max. 45 mm |
Secured switching distance sao | min. 15 mm |
Mounting distance | |
Switching hysteresis | 1 ... 3 mm |
Similar products:
EUCHNER Non-contact safety switch CES-AP-CR2-CH-SF-100775; 100775
Non-contact safety switch CES-AP-CR2-... , with latching connection Safety switch with integrated evaluation electronics No series connection Short circuit monitoring
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switches CES-I-AP-M-C04-SK-117325; 117325
Non-contact safety switches CES-I-AP-.-C04-…, M8 Safety switch with integrated evaluation electronics No series connection Short circuit monitoring 2 safety
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switches CES-I-AP-M-C04-U05-117328; 117328
Non-contact safety switches CES-I-AP-.- C04-…, flying lead Safety switch with integrated evaluation electronics No series connection Short circuit monitoring
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switch CES-AP-CL2-CH-L10-106190; 106190
Non-contact safety switch CES-AP-CL2-..., flying lead, PVC Safety switch with integrated evaluation electronics No series connection Short circuit monitoring 2 safety
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switch CES-AP-CL2-CH-L20-106194; 106194
Non-contact safety switch CES-AP-CL2-..., flying lead, PVC Safety switch with integrated evaluation electronics No series connection Short circuit monitoring 2 safety
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switch CES-AP-CL2-CH-SB-106551; 106551
Non-contact safety switch CES-AP-CL2-... , M12, PUR Safety switch with integrated evaluation electronics No series connection Short circuit monitoring 2 safety outputs
-
(Out of stock)
Price on request