EUCHNER Non-contact safety switch CES-AR-CL2-AH-L10-109051; 109051

EUCHNER Non-contact safety switch CES-AR-CL2-AH-L10-109051; 109051

Non-contact safety switch CES-AR-CL2-..., with flying lead, PUR Safety switch with integrated evaluation electronics Up to 20 switches in series Short circuit monitoring...

Brand: EUCHNER
Product Code: 109051
Availability: Check availability
Price on request

Non-contact safety switch CES-AR-CL2-..., with flying lead, PUR

  • Safety switch with integrated evaluation electronics
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Door hinge left
  • Category 4 / PL e according to EN ISO 13849-1
  • Connecting cable PUR, 10 m, flying lead, 8-core
  • Unicode
  • Two safety screws M4x14 included

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E346349_1/1DGUV_ET 19009_ET 19010

Workspace

Repeat accuracy R  
according to EN 60947-5-2 <= 10

Electrical connection values

Fuse  
external (operating voltage) 0.25 ... 8 A
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC  
UB 24 V DC -15% ... +15% regulated, residual ripple<5%
Turn-on time  
Safety outputs max. 400 ms
EMC protection requirements Acc. to EN IEC 60947-5-3
Risk time according to EN 60947-5-3 max. 260 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Safety class III
Current consumption max. 50 mA 
Degree of contamination (external, according to EN 60947-1) 3
  Monitoring output OUT
Output type p-switching, short circuit-proof
Output voltage 0.8 x UB ... UB V DC
Switching current max. 50 mA
  Safety outputs OA / OB
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage  
HIGH U(OA,OB) UB-1.5V ... UB V DC 
LOW U(OA,OB) 0 ... 1 V DC
rated conditional short-circuit current 100 A
Discrepancy time max. 10 ms
Utilization category  
DC-13 24 V 200 mA 
Off-state current Ir max. 0.25 mA
Switching current  
per safety output 1 ... 200 mA
Test pulse duration max. 1 ms 
Test pulse interval min. 140 ms

Mechanical values and environment

Connection type Connecting cable PUR, length 10 m
Tightening torque  
Fixing screws max. 1 Nm
Ready delay 10 s
Dynamic bending radius 10 x cable diameter
Static bending radius 5 x cable diameter
Installation orientation any
Switching frequency max. 1 Hz
Mounting distance  
between 2 switches or 2 actuators min. 120 mm
Mounting type Surface mounting on metal
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67/IP69K
Cable ambient temperature (dynamic) -25 ... +65 °C
Cable ambient temperature (static) -30 ... +65 °C
Material  
Housing Plastic, PBT

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

  PL Maximum SIL PFHD Category Mission time
Monitoring of the guard position PL e - 1.9x10-9 4 20 y

 

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BLN-R2-100776, CES-A-BLN-U2-103450, CES-A-BLN-L2-104510, CES-A-BLN-U2-112710

Switch-on distance 15 mm
Secured switch-off distance sar  
in x/z direction max. 40 mm
in y direction max. 60 mm
Secured switching distance sao min. 10 mm
Switching hysteresis 1 ... 2 mm

In combination with actuator CES-A-BDN-06-104730

Switch-on distance 19 mm
Secured switch-off distance sar  
in x/z direction max. 40 mm
in y direction max. 60 mm
Secured switching distance sao min. 14 mm
Switching hysteresis 1 ... 2 mm

Similar products:


EUCHNER Non-contact safety switch CES-AR-CR2-AH-SG-105751; 105751

Non-contact safety switch CES-AR-CR2-... , plug connector M8 Safety switch with integrated evaluation electronics Up to 20 switches in series Short circuit monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CES-AR-CR2-CH-L05-109044; 109044

Non-contact safety switch CES-AR-CR2-..., with flying lead, PUR Safety switch with integrated evaluation electronics Up to 20 switches in series Short circuit monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switches CES-I-AR-U-C04-U10-119471; 119471

Non-contact safety switches CES-I-AR-.-C04-…, flying lead Safety switch with integrated evaluation electronics Up to 20 switches in series Short circuit monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switches CES-I-AR-U-C04-U20-119472; 119472

Non-contact safety switches CES-I-AR-.-C04-…, flying lead Safety switch with integrated evaluation electronics Up to 20 switches in series Short circuit monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CES-AR-C01-CH-SA; 098942

Non-contact safety switch CES-AR-C01... Safety switch with integrated evaluation electronics Up to 20 switches in series Short circuit monitoring 2 safety outputs
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CES-AR-C01-EH-SA; 098582

Non-contact safety switch CES-AR-C01... Safety switch with integrated evaluation electronics Up to 20 switches in series Short circuit monitoring 2 safety outputs
-
Need to order

(Out of stock)

Price on request

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs