EUCHNER Non-contact safety switch CET-AR-..., M12, with Bowden wire ; 110114
Non-contact safety switch CET-AR-..., M12, with Bowden wire Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N Up...
Price on request
Non-contact safety switch CET-AR-..., M12, with Bowden wire
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Multicode
- Door monitoring output
- Indication of the door position by LED
- Wire front release (bowden), 3m, automatic return
- Approach direction A (default setting on delivery)
Approvals
Mechanical values and environment
Housing material | |
Slide | Stainless steel |
Safety switch housing | Die-cast aluminum |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
Y | ±5 mm |
Z | ±4 mm |
X | ±5 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5 and 8-pin |
Approach speed | max.20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Electrical connection ratings
Operating voltage DC | |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
LED | 24 V DC -15% ... 10% |
Current consumption | |
IB | 80 mA |
ICM | 480 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 8 A |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
Power consumption | |
Solenoid | max.12 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT | 1 ... 50 mA |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Switching delay from state change | max.400 ms |
Monitoring output OUT D | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT D | 1 ... 50 mA |
Output voltage | |
OUT D | 0,8xUB ... UB V DC |
Switching delay from state change | max.700 ms |
Safety outputs OA/OB | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Low U(OA) / U(OB) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Single device | max.400 ms |
Delay per device | 5 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Work area
Repeat accuracy R | |
According to EN 60947-5-2 | 10 % |
Other
C number | |
C2290 | With wire front release (bowden) mounted |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position | |
Category | |
Head upward | 3 |
Head downward or horizontal | 4 |
Performance Level | PL e |
PFHD | |
Head upward | 4.29 x 10-8 |
Head downward or horizontal | 3.1 x 10-9 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Mission time | 20 y |
Similar products:
EUCHNER Non-contact safety switch CET1-AR-CDA-CH-50X-SH-113255; 113255
Non-contact safety switch CET-AR-..., RC18, and double ramp Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N Up
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switch CET2-AR-CRA-AH-50X-SH-110205; 110205
Non-contact safety switch CET-AR-..., RC18 Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N Up to 20 switches in
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switch CET2-AR-CRA-CH-50F-SG-C2312-109941; 109941
Non-contact safety switch CET-AR-..., M12, with escape release Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switch CET3-AR-CRA-CH-50X-SG-110906; 110906
Non-contact safety switch CET-AR-..., M12 Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N Up to 20 switches in
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switch CET3-AR-CRA-CH-50X-SH-110104; 110104
Non-contact safety switch CET-AR-..., RC18 Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N Up to 20 switches in
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switch CET1-AR-CDA-CH-50X-SG-109231; 109231
Non-contact safety switch CET-AR-..., M12, with double ramp Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N Up
-
(Out of stock)
Price on request