EUCHNER Non-contact safety switch CET1-AR-CRA-CH-50F-SG-110241; 110241

EUCHNER Non-contact safety switch CET1-AR-CRA-CH-50F-SG-110241; 110241

Non-contact safety switch CET-AR-..., M12, with escape release Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N...

Brand: EUCHNER
Product Code: 110241
Availability: Check availability
Price on request

Non-contact safety switch CET-AR-..., M12, with escape release

  • Safety switch with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • With 2 plug connectors M12
  • Multicode
  • Escape release, 75 mm long
  • Approach direction A (delivery state)

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/8

Workspace

Repeat accuracy R  
according to EN 60947-5-2 10 %

Electrical connection values

Fuse  
external (operating voltage UCM) 0.5 ... 8 A
external (operating voltage UB) 0.25 ... 8 A
Power consumption  
Solenoid 11 W
Operating voltage DC  
LED1, LED2 24 V DC -15% V DC ... +10% V DC
UB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category  
DC-13 24 V 200 mA 
Solenoid operating voltage DC  
UCM 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Risk time according to EN 60947-5-3 max. 400 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Switching load  
according to UL 24V DC, Class 2 
Safety class  
EN IEC 61140 III
Current consumption  
IB 80 mA
ICM 450 mA
Test pulse duration max. 1 ms
Degree of contamination (external, according to EN 60947-1) 3
  Monitoring output OUT
Output type Semiconductor output, p-switching, short circuit-proof
Output voltage  
OUT 0.8xUB ... UB V DC
Output current  
OUT 1 ... 50 mA
  Safety outputs OA / OB
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage  
HIGH U(OA,OB) UB-1.5V ... UB V DC 
LOW U(OA,OB) 0 ... 1 V DC
Output current  
per safety output 1 ... 200 mA
Discrepancy time  
both safety outputs max. 10 ms
Turn-on time  
Safety outputs 400 ms
Off-state current Ir max. 0.25 mA
Risk time according to EN 60947-5-3  
Single device  

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 2 plug connectors M12, 5- and 8-pin
Ready delay 10 s
Installation orientation any 
Switching frequency max. 0.5 Hz
Degree of freedom X ±5 mm
Degree of freedom Y ±5 mm
Degree of freedom Z ±4 mm
Mechanical life 2 x 10⁶
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67 
Ambient temperature  
at UB = 24 V DC -20 ... +55 °C
Material  
Ramp Stainless steel
Safety switch housing Die-cast aluminum
Locking force Fmax 6500 N
Locking force FZh 5000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
  Control of guard locking
Category Depending on external control of guard locking
Performance Level Depending on external control of guard locking 
PFHD Depending on external control of guard locking 
  Monitoring of guard locking and the guard position
Category  
Any installation orientation 4
Performance Level PL e
PFHD  
Any installation orientation 3.1 x 10-9

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Similar products:


EUCHNER Non-contact safety switch CET1-AR-CRA-AH-50X-SH-110203; 110203

Non-contact safety switch CET-AR-..., RC18 Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N Up to 20 switches in
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CET3-AR-CRA-AH-50F-SH-113148; 113148

Non-contact safety switch CET-AR-..., RC18, with escape release Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CET4-AR-CRA-AH-50X-SG-C2355-162555; 162555

Non-contact safety switch CET-AR-..., M12 Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N Up to 20 switches in
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CET4-AR-CRA-AH-50X-SH-110201; 110201

Non-contact safety switch CET-AR-..., RC18 Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N Up to 20 switches in
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CET3-AR-CRA-AH-50F-SH-C2312-111725; 111725

Non-contact safety switch CET-AR-..., RC18, with escape release Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CET1-AR-CRA-AH-50X-SG-103418; 103418

Non-contact safety switch CET-AR-..., M12 Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N Up to 20 switches in
-
Need to order

(Out of stock)

Price on request

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products