EUCHNER Non-contact safety switch CET3-AP-CRA-AH-50X-SI-C2290-121367; 121367

EUCHNER Non-contact safety switch CET3-AP-CRA-AH-50X-SI-C2290-121367; 121367

Non-contact safety switch CET-AP-..., M12, with wire front release (bowden), for connection to decentralized peripheral systems Safety switch with guard locking...

Brand: EUCHNER
Product Code: 121367
Availability: Check availability
Price on request

Non-contact safety switch CET-AP-..., M12, with wire front release (bowden), for connection to decentralized peripheral systems

  • Safety switch with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Direct connection to decentralized peripheral systems (e.g. ET200pro)
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • With 2 plug connectors M12
  • Unicode
  • Indication of the door position by LED
  • Wire front release (bowden), 5 m
  • Approach direction A (delivery state)

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/8

Workspace

Repeat accuracy R  
according to EN 60947-5-2 10 %

Electrical connection values

Fuse  
external (operating voltage UB) 0.25 ... 8 A
external (solenoid operating voltage UCM) 0.5 ... 8 A
Power consumption  
Solenoid 11 W
Connecting cable 30V DC, 2A 
Operating voltage DC  
UB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
LED 24 V DC -15% V DC ... +10% V DC
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category  
DC-13 24 V 200 mA 
Solenoid operating voltage DC  
UCM 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Risk time according to EN 60947-5-3 max. 400 ms
Switching load  
according to UL 24V DC, Class 2 
Safety class  
EN IEC 61140 III
Current consumption  
IB 80 mA
ICM 450 mA
Test pulse duration max. 0.3 ms 
Degree of contamination (external, according to EN 60947-1) 3
  Safety outputs OA / OB
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage  
LOW U(OA,OB) 0 ... 1 V DC
HIGH U(OA,OB) UB-1.5V ... UB V DC
Discrepancy time  
both safety outputs max. 10 ms
Turn-on time 400 ms
Off-state current Ir max. 0.25 mA
Risk time according to EN 60947-5-3  
Single device  
Switching current  
per safety output OA / OB 1 ... 200 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 2 plug connector M12, 5-pin
Ready delay 1 s
Installation orientation any 
Switching frequency max. 0.5 Hz
Degree of freedom X ±5 mm
Degree of freedom Y ±5 mm
Degree of freedom Z ±4 mm
Mechanical life 2 x 10⁶
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67 
Ambient temperature  
at UB = 24 V DC -20 ... +55 °C
Material  
Safety switch housing Die-cast aluminum
Ramp Stainless steel
Locking force Fmax 6500 N
Locking force FZh 5000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
  Control of guard locking
Category Depending on external control of guard locking
Performance Level Depending on external control of guard locking
PFHD Depending on external control of guard locking
  Monitoring of guard locking and the guard position
Category  
Any installation orientation 4
Performance Level PL e
PFHD  
Any installation orientation 3.1 x 10-9

Miscellaneous

C number  
C2290 with mounted wire front release (bowden)
The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Similar products:


EUCHNER Non-contact safety switch CET3-AP-CRA-AH-50F-SA-124601; 124601

Non-contact safety switch CET-AP-..., M12, with escape release Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CET3-AP-CRA-AH-50F-SH-C2312-119106; 119106

Non-contact safety switch CET-AP-..., with plug connector RC18 and escape release Safety switch with guard locking and integrated evaluation electronics Locking
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CET3-AP-CRA-AH-50F-SI-114073; 114073

Non-contact safety switch CET-AP-..., with escape release, for connection to decentralized peripheral systems Safety switch with guard locking and integrated evaluation
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CET4-AP-CRA-CH-50F-SA-161178; 161178

Non-contact safety switch CET-AP-..., M12 Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N Short circuit monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CET4-AP-CRA-CH-50X-SA-122413; 122413

Non-contact safety switch CET-AP-..., M12 Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N Short circuit monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CET3-AP-CRA-AH-50X-SA ; 122398

Non-contact safety switch CET3-AP-CRA-AH-50X-SA ; 122398 // Safety switch with guard locking and integrated evaluation electronics Locking force up to 6,500 N Short
-
Need to order

(Out of stock)

Price on request