EUCHNER Non-contact safety switches CES-I-AP-M-C04-USI-117323; 117323
Non-contact safety switches CES-I-AP-.-C04-, M12; pin 5 not used Safety switch with integrated evaluation electronics No series connection Short circuit monitoring...
Price on request
Non-contact safety switches CES-I-AP-.-C04-, M12; pin 5 not used
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces
- Connecting cable PUR, 0.1 m, plug connector M12, 5-pin; pin 5 not used
- Multicode
Approvals
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | <= 10 |
Electrical connection values
Fuse | |
external (operating voltage) | 0.25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB | 24 V DC -15% ... +15% regulated, residual ripple<5%, PELV |
Turn-on time | |
Safety outputs | max. 300 ms |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Risk time according to EN 60947-5-3 | max. 260 ms |
Safety class | III |
Current consumption | |
no load on outputs | max. 35 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety outputs FO1A / FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1.5V ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
rated conditional short-circuit current | 100 A |
Discrepancy time | max. 10 ms |
Utilization category | |
DC-13 | 24 V 150 mA |
Off-state current Ir | max. 0.25 mA |
Switching current | |
per safety output | 1 ... 150 mA |
Test pulse duration | max. 0.3 ms |
Test pulse interval | min. 100 ms |
Mechanical values and environment
Connection type | PUR cable, 100 mm, with plug connector M12x1, 5-pin; pin 5 not used |
Tightening torque | |
Fixing screws | max. 0.8 Nm |
Ready delay | 0.5 s |
Dynamic bending radius | 10 x cable diameter |
Static bending radius | 5 x cable diameter |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Mounting distance | |
between 2 switches or 2 actuators | min. 80 mm |
Mounting type | Surface mounting on metal |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67 |
Cable ambient temperature (dynamic) | -25 ... +65 °C |
Cable ambient temperature (static) | -25 ... +65 °C |
Material | |
Rubber support | NBR 80 ±5 Shore |
Housing | Plastic, PBT |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL e | - | 4.1x10-9 | 4 | 20 y |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures |
Additional feature | Rubber support included |
In combination with actuator CES-A-BDN-06-161742
Switch-on distance | |
Installation position A | 26 mm |
Installation position C | 23 mm |
Secured switch-off distance sar | |
Installation position A | max. 77 mm |
Installation position C | max. 72 mm |
Secured switching distance sao | |
Installation position A | min. 16 mm |
Installation position C | min. 10 mm |
Switching hysteresis | 1 ... 2 mm |
In combination with actuator CES-A-BDN-06-104730
Switch-on distance | |
Installation position C or D (broad side) | 15 mm |
Installation position A or B (front side) | 19 mm |
Secured switch-off distance sar | |
in x/z direction | max. 40 mm |
in y direction | max. 60 mm |
Secured switching distance sao | |
Installation position C or D (broad side) | min. 10 mm |
Installation position A or B (front side) | min. 14 mm |
Switching hysteresis | 1 ... 2 mm |
In combination with actuator CES-A-BBN-C04-115271, CES-A-BBN-C04-EX-137527
Switch-on distance | |
Installation position C or D (broad side) | 11 mm |
Installation position A or B (front side) | 15 mm |
Secured switch-off distance sar | |
Similar products:
EUCHNER Non-contact safety switch CES-AP-CL2-AH-SB-111747; 111747
Non-contact safety switch CES-AP-CL2-... , M12; pin 5 not used, PUR Safety switch with integrated evaluation electronics No series connection Short circuit monitoring
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switch CES-AP-CL2-AH-SF-105294; 105294
Non-contact safety switch CES-AP-CL2-... , with latching connection Safety switch with integrated evaluation electronics No series connection Short circuit monitoring
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switch CES-AP-CR2-CH-SB-106550; 106550
Non-contact safety switch CES-AP-CR2-... , M12, PUR Safety switch with integrated evaluation electronics No series connection Short circuit monitoring 2 safety outputs
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switch CES-AP-CR2-CH-SB-109168; 109168
Non-contact safety switch CES-AP-CR2-... , M12; pin 5 not used, PUR Safety switch with integrated evaluation electronics No series connection Short circuit monitoring
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switches CES-I-AP-U-C04-USI-115150; 115150
Non-contact safety switches CES-I-AP-.-C04-, M12; pin 5 not used Safety switch with integrated evaluation electronics No series connection Short circuit monitoring
-
(Out of stock)
Price on request
EUCHNER Non-contact safety switches CES-I-AP-U-C14-U20-158632; 158632
Non-contact safety switches CES-I-AP-.-C14-…, with cable end sleeves Safety switch with integrated evaluation electronics Safety switch CES-C04 encapsulated
-
(Out of stock)
Price on request