EUCHNER Safety switch NZ1VZ-538E3VSM07-M; 088046
Safety switch NZ.VZ.VSM (guard locking, closed-circuit current principle) Housing according to EN 50041 Cable entry M20 x 1.5...
Price on request
Safety switch NZ.VZ.VSM (guard locking, closed-circuit current principle)
- Housing according to EN 50041
- Cable entry M20 x 1.5
Approvals
Electrical connection values
Connection cross section | 0.34 ... 1.5 mm² |
Rated insulation voltage Ui | |
AC/DC | 250 V |
Rated impulse withstand voltage Uimp | 2.5 kV |
Utilization category | |
AC-15 | 4 A 230 V |
DC-13 | 4 A 24 V |
Short circuit protection according to IEC 60269-1 | 4A gG |
Solenoid operating voltage | |
AC | 110 V -15% ... 10% |
Switching voltage | |
min. at 10 mA | 12 V |
Switching current | |
min. at 24 V | 1 mA |
thermal rated current Ith | 4 A |
Mechanical values and environment
Approach speed | max. 20 m/min |
Approach direction | A |
Connection type | |
1 x | M20 x 1.5 |
Number of door position positively driven contacts | 2 |
Extraction force | 40 N |
Actuation frequency | max. 1200 1/h |
Actuating force | 45 N |
Installation orientation | any |
Insertion depth | 52 mm |
Solenoid alignment | 3 |
Mechanical life | 2 x 10⁶ |
Retention force | 35 N |
Switching principle | Slow-action switching contact |
Degree of protection | IP65 |
Ambient temperature | -25 ... +80 °C |
Material | |
Housing | Anodized die-cast alloy |
Contact | Silver alloy, gold flashed |
Locking force Fmax | 2000 N |
Locking force FZh | 1500 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
B10D | Mission time | |
---|---|---|
Monitoring of the guard position | 4.5x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V |
PL | Maximum SIL | Category | Mission time | |
---|---|---|---|---|
Control of guard locking | Depending on external control of guard locking | 20 y |
In combination with actuator ACTUATOR-Z-GN
Overtravel | 16 mm |
In combination with actuator ACTUATOR-Z-G
Overtravel | 4 mm |
Similar products:
EUCHNER Safety switch NZ2VZ-3131E3VSE04; 074474
Safety switch NZ.VZ.VSE, plug connector SR11 (guard locking, open-circuit current principle) Housing according to EN 50041 Plug connector SR11
-
(Out of stock)
Price on request
EUCHNER Safety switch NZ1VZ-528E3VSE09-M; 088047
Safety switch NZ.VZ.VSE (guard locking, open-circuit current principle) Housing according to EN 50041 Cable entry M20 x 1.5
-
(Out of stock)
Price on request
EUCHNER Safety switch NZ1VZ-528E3VSE09L220-M; 090335
Safety switch NZ.VZ.VSE (guard locking, open-circuit current principle) Housing according to EN 50041 Cable entry M20 x 1.5 LED indicator
-
(Out of stock)
Price on request
EUCHNER Safety switch NZ1VZ-528E3VSM04L060-M; 082126
Safety switch NZ.VZ.VSM (guard locking, closed-circuit current principle) Housing according to EN 50041 Cable entry M20 x 1.5 LED indicator
-
(Out of stock)
Price on request
EUCHNER Safety switch NZ2VZ-2131E3VSH-8C-GMMF; 093611
Safety switch NZ.VZ.VSH, plug connector MR8 (manual release) Housing according to EN 50041 Manual release Plug connector MR8
-
(Out of stock)
Price on request
EUCHNER Safety switch NZ2VZ-2131E3VSM04; 074471
Safety switch NZ.VZ.VSM, plug connector SR11 (guard locking, closed-circuit current principle) Housing according to EN 50041 Plug connector SR11
-
(Out of stock)
Price on request