EUCHNER Safety switch STP3D-4141A024M; 097891
Safety switch STP with door monitoring contact Actuating head made of metal Auxiliary release on the front With door monitoring contact With insertion funnel...
Price on request
Safety switch STP with door monitoring contact
- Actuating head made of metal
- Auxiliary release on the front
- With door monitoring contact
- With insertion funnel
Approvals
Electrical connection values
Power consumption | 8 W |
Connection cross section | 0.34 ... 1.5 mm² |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2.5 kV |
Utilization category | |
AC-15 | 4 A 230 V |
DC-13 | 4 A 24 V |
Short circuit protection according to IEC 60269-1 | 4A gG |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Solenoid duty cycle | 100 % |
Switching voltage | |
min. at 10 mA | 12 V |
Switching current | |
min. at 24 V | 1 mA |
thermal rated current Ith | 4 A |
Mechanical values and environment
Approach speed | max. 20 m/min |
Approach direction | A |
Connection type | |
3 x | M20 x 1.5 |
Number of door position positively driven contacts | 2 |
Number of guard lock monitoring positively driven contacts | 2 |
Extraction force | 30 N |
Actuation frequency | max. 1200 1/h |
Actuating force | 35 N |
Installation orientation | any |
Insertion depth | 28.5 mm |
Mechanical life | 1 x 10⁶ |
Retention force | 20 N |
Switching principle | Slow-action switching contact |
Degree of protection | IP67 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Reinforced thermoplastic |
Contact | Silver alloy, gold flashed |
Locking force Fmax | 2500 N |
Locking force FZh | 2000 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Control of guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Monitoring of guard locking and the guard position | |
B10D | 5 x 10⁶ |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
B10D | Mission time | |
---|---|---|
Monitoring of the guard position | 5x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V |
PL | Maximum SIL | Category | Mission time | |
---|---|---|---|---|
Control of guard locking | Depending on external control of guard locking | 20 y |
In combination with actuator ACTUATOR-S-GT-LN
Overtravel | 5 mm |
Similar products:
EUCHNER Safety switch STP-TW-3A-4141AC024M; 100746
Safety switch STP-TWIN with door monitoring contact Two actuating heads made of metal Simultaneous monitoring of two safety doors Auxiliary release on the front
-
(Out of stock)
Price on request
EUCHNER Safety switch STP-TW-3A-4141AC024SEM4AS1; 102354
Safety switch STP-TWIN ASi, plug connector M12 (closed-circuit current principle) Two actuating heads made of metal Auxiliary release on the front With plug connector
-
(Out of stock)
Price on request
EUCHNER Safety switch STP2A-528A024M; 099855
Safety switch STP without door monitoring contact Actuating head made of metal Auxiliary release on the front Without door monitoring contact
-
(Out of stock)
Price on request
EUCHNER Safety switch STP2A-538A024M; 092260
Safety switch STP without door monitoring contact Actuating head made of metal Auxiliary release on the front Without door monitoring contact
-
(Out of stock)
Price on request
EUCHNER Safety switch STP3A-4131A024SR11; 103994
Safety switch STP, plug connector SR11, with door monitoring contact Actuating head made of metal Auxiliary release on the front With door monitoring contact
-
(Out of stock)
Price on request
EUCHNER Safety switch STP4A-4121A024SR11; 099301
Safety switch STP, plug connector SR11, with door monitoring contact Actuating head made of metal Auxiliary release on the front With door monitoring contact
-
(Out of stock)
Price on request