EUCHNER Safety switch TP1-538A024L024M; 093459
Safety switch TP without door monitoring contact Auxiliary release on the front Without door monitoring contact Increased horizontal overtravel With LED function...
Price on request
Safety switch TP without door monitoring contact
- Auxiliary release on the front
- Without door monitoring contact
- Increased horizontal overtravel
- With LED function display
Approvals
Electrical connection values
Power consumption | 8 W |
Connection cross section | 0.34 ... 1.5 mm² |
Display module | |
AC/DC | 24 V -15% ... +10% |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2.5 kV |
Utilization category | |
DC-13 | 4 A 24 V |
AC-15 | 4 A 230 V |
Short circuit protection according to IEC 60269-1 | 4A gG |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Solenoid duty cycle | 100 % |
Switching voltage | |
min. at 10 mA | 12 V |
Switching current | |
min. at 24 V | 1 mA |
thermal rated current Ith | 4 A |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | |
3 x | M20 x 1.5 |
Number of guard lock monitoring positively driven contacts | 2 |
Extraction force | 20 N |
Actuation frequency | max. 1200 1/h |
Actuating force | 10 N |
Installation orientation | any |
Mechanical life | 1 x 10⁶ |
Retention force | 10 N |
Switching principle | Slow-action switching contact |
Degree of protection | IP67 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Reinforced thermoplastic |
Contact | Silver alloy, gold flashed |
Locking force Fmax | 1300 N |
Locking force FZh | 1000 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Monitoring of guard locking and the guard position | |
B10D | 3 x 10⁶ |
In combination with actuator ACTUATOR-P-GT
Horizontal overtravel | 2 mm |
Vertical overtravel | 1.5 mm |
In combination with actuator ACTUATOR-P-GNT
Horizontal overtravel | 7 mm |
Similar products:
EUCHNER Safety switch TP2-4131K024SR11; 088218
Safety switch TP, plug connector SR11, without door monitoring contact, increased vertical overtravel Auxiliary release on the front Without door monitoring contact
-
(Out of stock)
Price on request
EUCHNER Safety switch TP3-2131A024MC1761; 084290
Safety switch TP with door monitoring contact, additional cable entry Auxiliary release on the front With door monitoring contact Increased horizontal overtrave
-
(Out of stock)
Price on request
EUCHNER Safety switch TP3-4121A024SR11; 088206
Safety switch TP, plug connector SR11, with door monitoring contact Auxiliary release on the front With door monitoring contact Increased horizontal overtravel Plug
-
(Out of stock)
Price on request
EUCHNER Safety switch TP3-4131K230M; 084258
Safety switch TP with door monitoring contact, increased vertical overtravel Auxiliary release on the front With door monitoring contact Increased overtravel for
-
(Out of stock)
Price on request
EUCHNER Safety switch TP1-528A230M; 084304
Safety switch TP without door monitoring contact Auxiliary release on the front Without door monitoring contact Increased horizontal overtravel
-
(Out of stock)
Price on request
EUCHNER Safety switch TP with door monitoring contact, escape release TP3-2131A024MC1743; 084285
Safety switch TP with door monitoring contact, escape release TP3-2131A024MC1743; 084285 Auxiliary release on the front Escape release from the rear With door monitoring
-
(Out of stock)
Price on request