EUCHNER Safety switch TP2-528A110SR6; 087444
Safety switch TP, plug connector SR6, without door monitoring contact Auxiliary release on the front Without door monitoring contact Increased horizontal overtr...
Price on request
Safety switch TP, plug connector SR6, without door monitoring contact
- Auxiliary release on the front
- Without door monitoring contact
- Increased horizontal overtravel
Approvals
Electrical connection values
Power consumption | 10 W |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2.5 kV |
Utilization category | |
DC-13 | 4 A 24 V |
AC-15 | 4 A 230 V |
Short circuit protection according to IEC 60269-1 | 4A gG |
Solenoid operating voltage | |
AC | 110 V -15% ... +10% |
Solenoid duty cycle | 100 % |
Switching voltage | |
min. at 10 mA | 12 V |
Switching current | |
min. at 24 V | 1 mA |
thermal rated current Ith | 4 A |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | |
1 x | Plug connector SR6 |
Number of guard lock monitoring NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 1 |
Extraction force | 20 N |
Actuation frequency | max. 1200 1/h |
Actuating force | 10 N |
Installation orientation | any |
Mechanical life | 1 x 10⁶ |
Retention force | 10 N |
Switching principle | Slow-action switching contact |
Degree of protection | IP65 |
Ambient temperature | -20 ... +55 °C |
Material | |
Contact | Silver alloy, gold flashed |
Housing | Reinforced thermoplastic |
Locking force Fmax | 1300 N |
Locking force FZh | 1000 N |
Guard locking principle | Open-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Monitoring of guard locking and the guard position | |
B10D | 3 x 10⁶ |
In combination with actuator ACTUATOR-P-GNT
Horizontal overtravel | 7 mm |
In combination with actuator ACTUATOR-P-GT
Horizontal overtravel | 2 mm |
Vertical overtravel | 1.5 mm |
Similar products:
EUCHNER Safety switch TP2-528A110M; 084330
Safety switch TP without door monitoring contact Auxiliary release on the front Without door monitoring contact Increased horizontal overtravel
-
(Out of stock)
Price on request
EUCHNER Safety switch TP3-2131A024SR11; 088205
Safety switch TP, plug connector SR11, with door monitoring contact Auxiliary release on the front With door monitoring contact Increased horizontal overtravel Plug
-
(Out of stock)
Price on request
EUCHNER Safety switch TP3-4121K024SR11; 088221
Safety switch TP, plug connector SR11, with door monitoring contact, increased vertical overtravel Auxiliary release on the front With door monitoring contact Increased
-
(Out of stock)
Price on request
EUCHNER Safety switch TP3-4141A024SEM4AS1; 088256
Safety switch TP AS1, plug connector M12 (closed-circuit current principle) Auxiliary release on the front Increased horizontal overtravel Optionally without guard
-
(Out of stock)
Price on request
EUCHNER Safety switch TP1-4131A024SR11; 088202
Safety switch TP, plug connector SR11, without door monitoring contact Auxiliary release on the front Without door monitoring contact Increased horizontal overtravel
-
(Out of stock)
Price on request
EUCHNER Safety switch TP1-538A024M; 084310
Safety switch TP without door monitoring contact Auxiliary release on the front Without door monitoring contact Increased horizontal overtravel
-
(Out of stock)