EUCHNER Safety switch TX2C-A024M; 082928
Safety switch TX Auxiliary release on the front With door monitoring contact...
Price on request
Safety switch TX
- Auxiliary release on the front
- With door monitoring contact
Approvals
Operating and display elements
LED display | Operating voltage corresponds to the solenoid voltage |
Electrical connection values
Power consumption | 8 W |
Connection cross section | 0.34 ... 1.5 mm² |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2.5 kV |
Utilization category | |
DC-13 | 4 A 24 V |
AC-15 | 4 A 230 V |
Short circuit protection according to IEC 60269-1 | 4A gG |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Solenoid duty cycle | 100 % |
Switching voltage | |
min. at 10 mA | 12 V |
Switching current | |
min. at 24 V | 1 mA |
thermal rated current Ith | 4 A |
Mechanical values and environment
Approach speed | max. 20 m/min |
Approach direction | A |
Connection type | |
3 x | M20 x 1.5 |
Number of door position NO contacts | 1 |
Number of guard lock monitoring NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 |
Extraction force | 35 N |
Actuation frequency | max. 1200 1/h |
Actuating force | 35 N |
Installation orientation | any |
Insertion depth | 32 mm |
Mechanical life | 1 x 10⁶ |
Retention force | 20 N |
Switching principle | Slow-action switching contact |
Degree of protection | IP67 |
Ambient temperature | -20 ... +80 °C |
Material | |
Housing | Die-cast alloy cathodically dipped |
Contact | Silver alloy, gold flashed |
Locking force Fmax | 1700 N |
Locking force FZh | 1300 N |
Guard locking principle | Open-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
B10D | Mission time | |
---|---|---|
Monitoring of the guard position | 5x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V |
In combination with actuator ACTUATOR-X-GNQ
Overtravel | 8 mm |
In combination with actuator ACTUATOR-X-GQ
Overtravel | 1 mm |
Similar products:
EUCHNER Safety switch TX1B-A024M; 082921
Safety switch TX Auxiliary release on the front With door monitoring contact
-
(Out of stock)
Price on request
EUCHNER Safety switch TX1B-A024MC2129; 097623
Safety switch TX, plug connector M12, for connection to decentralized peripheral systems Auxiliary release on the front With door monitoring contact Separate plug
-
(Out of stock)
Price on request
EUCHNER Safety switch TX1D-A024MC2081; 095025
Safety switch TX Auxiliary release on the front With door monitoring contact
-
(Out of stock)
Price on request
EUCHNER Safety switch TX2B-A024BH10; 085381
Safety switch TX, plug connector BH10 Auxiliary release on the front With door monitoring contact Plug connector BH10
-
(Out of stock)
Price on request
EUCHNER Safety switch TX3B-A024RC18; 082964
Safety switch TX, plug connector M23 (RC18), release under load Auxiliary release on the front Release under load possible With door monitoring contact Plug connector
-
(Out of stock)
Price on request
EUCHNER Safety switch TX3B-A024RC18C1991; 093559
Safety switch TX, plug connector M23 (RC18) Auxiliary release on the front Escape release on the rear side Release under load possible With door monitoring contact
-
(Out of stock)
Price on request