EUCHNER Safety switch TX3B-A024M; 082952

EUCHNER Safety switch TX3B-A024M; 082952

Safety switch TX, release under load Auxiliary release on the front Release under load possible With door monitoring contact...

Brand: EUCHNER
Product Code: 082952
Availability: Check availability
Price on request

Safety switch TX, release under load

  • Auxiliary release on the front
  • Release under load possible
  • With door monitoring contact

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_2/1CCC_2020980305000541_CQC2008010305306207

Operating and display elements

LED display Operating voltage corresponds to the solenoid voltage 

Electrical connection values

Power consumption 8 W 
Connection cross section 0.34 ... 1.5 mm²
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2.5 kV
Utilization category  
AC-15 4 A 230 V
DC-13 4 A 24 V
Short circuit protection according to IEC 60269-1 4A gG
Solenoid operating voltage  
AC/DC 24 V -15% ... +10%
Solenoid duty cycle 100 %
Switching voltage  
min. at 10 mA 12 V
Switching current  
min. at 24 V 1 mA
Control voltage  
Us AC/DC 24 V
thermal rated current Ith 4 A

Mechanical values and environment

Approach speed max. 20 m/min
Approach direction A
Connection type  
3 x M20 x 1.5
Number of door position NC contacts 1
Number of guard lock monitoring NO contacts 1
Number of guard lock monitoring positively driven contacts 2
Extraction force 35 N
Actuation frequency max. 1200 1/h
Actuating force 35 N
Installation orientation any
Insertion depth 32 mm
Mechanical life 1 x 10⁶
Retention force 50 N 
Switching principle Slow-action switching contact
Degree of protection IP67
Ambient temperature -20 ... +80 °C
Material  
Housing Die-cast alloy cathodically dipped
Contact Silver alloy, gold flashed
Locking force Fmax 1700 N
Locking force FZh 1300 N
Guard locking principle Closed-circuit current principle 

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

  B10D Mission time
Monitoring of the guard position 5x106 20 y
Important! Values valid at DC-13 100 mA/24V


  PL Maximum SIL Category Mission time
Control of guard locking Depending on external control of guard locking 20 y

 

In combination with actuator ACTUATOR-X-GQ

Overtravel 1 mm

In combination with actuator ACTUATOR-X-GNQ

Overtravel 8 mm

Similar products:


EUCHNER Safety switchTX1C-A024N; 082945

Safety switch TX Auxiliary release on the front With door monitoring contact
-
Need to order

(Out of stock)

Price on request

EUCHNER Safety switch TX2C-A024N; 082947

Safety switch TX Auxiliary release on the front With door monitoring contact
-
Need to order

(Out of stock)

Price on request

EUCHNER Safety switch TX2C-A024RC18; 082940

Safety switch TX, plug connector M23 (RC18) Auxiliary release on the front With door monitoring contact Plug connector M23 (RC18)
-
Need to order

(Out of stock)

Price on request

EUCHNER Safety switch TX2C-A110M; 085388

Safety switch TX Auxiliary release on the front With door monitoring contact
-
Need to order

(Out of stock)

Price on request

EUCHNER Safety switch TX1C-A024M; 082922

Safety switch TX Auxiliary release on the front With door monitoring contact
-
Need to order

(Out of stock)

Price on request

EUCHNER Safety switch TX1C-A024MC2161; 099489

Safety switch TX, escape release Auxiliary release on the front Escape release on the rear side With door monitoring contact
-
Need to order

(Out of stock)

Price on request

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products