EUCHNER Safety switch TX3B-A024RC18; 082964
Safety switch TX, plug connector M23 (RC18), release under load Auxiliary release on the front Release under load possible With door monitoring contact Plug connector...
Price on request
Safety switch TX, plug connector M23 (RC18), release under load
- Auxiliary release on the front
- Release under load possible
- With door monitoring contact
- Plug connector M23 (RC18)
Approvals
Operating and display elements
LED display | Operating voltage corresponds to the solenoid voltage |
Electrical connection values
Power consumption | 8 W |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Utilization category | |
AC-15 | 4 A 24 V |
DC-13 | 4 A 24 V |
Short circuit protection according to IEC 60269-1 | 4A gG |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Solenoid duty cycle | 100 % |
Switching voltage | |
min. at 10 mA | 12 V |
Switching current | |
min. at 24 V | 1 mA |
Control voltage | |
Us AC/DC | 24 V |
thermal rated current Ith | 4 A |
Mechanical values and environment
Approach speed | max. 20 m/min |
Approach direction | A |
Connection type | |
1 x | Plug connector RC18 |
Number of door position NC contacts | 1 |
Number of guard lock monitoring NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 |
Extraction force | 35 N |
Actuation frequency | max. 1200 1/h |
Actuating force | 35 N |
Installation orientation | any |
Insertion depth | 32 mm |
Mechanical life | 1 x 10⁶ |
Retention force | 50 N |
Switching principle | Slow-action switching contact |
Degree of protection | IP65 |
Ambient temperature | -20 ... +80 °C |
Material | |
Housing | Die-cast alloy cathodically dipped |
Contact | Silver alloy, gold flashed |
Locking force Fmax | 1700 N |
Locking force FZh | 1300 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
B10D | Mission time | |
---|---|---|
Monitoring of the guard position | 5x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V |
PL | Maximum SIL | Category | Mission time | |
---|---|---|---|---|
Control of guard locking | Depending on external control of guard locking | 20 y |
In combination with actuator ACTUATOR-X-GNQ
Overtravel | 8 mm |
In combination with actuator ACTUATOR-X-GQ
Overtravel | 1 mm |
Similar products:
EUCHNER Safety switch TX1C-A024M; 082922
Safety switch TX Auxiliary release on the front With door monitoring contact
-
(Out of stock)
Price on request
EUCHNER Safety switch TX2B-A230M; 085389
Safety switch TX Auxiliary release on the front With door monitoring contact
-
(Out of stock)
Price on request
EUCHNER Safety switch TX2C-A024M; 082928
Safety switch TX Auxiliary release on the front With door monitoring contact
-
(Out of stock)
Price on request
EUCHNER Safety switch TX2C-A024N; 082947
Safety switch TX Auxiliary release on the front With door monitoring contact
-
(Out of stock)
Price on request
EUCHNER Safety switch TX1B-A110N; 085382
Safety switch TX Auxiliary release on the front With door monitoring contact
-
(Out of stock)
Price on request
EUCHNER Safety switch TX1B-A230M; 085385
Safety switch TX Auxiliary release on the front With door monitoring contact
-
(Out of stock)
Price on request