EUCHNER Safety switch TX3C-A024MC1991; 093118
Safety switch TX, escape release Auxiliary release on the front Escape release on the rear side Release under load possible With door monitoring contact...
Price on request
Safety switch TX, escape release
- Auxiliary release on the front
- Escape release on the rear side
- Release under load possible
- With door monitoring contact
Approvals
Operating and display elements
LED display | Operating voltage corresponds to the solenoid voltage |
Electrical connection values
Power consumption | 8 W |
Connection cross section | 0.34 ... 1.5 mm² |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2.5 kV |
Utilization category | |
AC-15 | 4 A 230 V |
DC-13 | 4 A 24 V |
Short circuit protection according to IEC 60269-1 | 4A gG |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Solenoid duty cycle | 100 % |
Switching voltage | |
min. at 10 mA | 12 V |
Switching current | |
min. at 24 V | 1 mA |
Control voltage | |
Us AC/DC | 24 V |
thermal rated current Ith | 4 A |
Mechanical values and environment
Approach speed | max. 20 m/min |
Approach direction | A |
Connection type | |
3 x | M20 x 1.5 |
Number of door position NO contacts | 1 |
Number of guard lock monitoring NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 |
Extraction force | 35 N |
Actuation frequency | max. 1200 1/h |
Actuating force | 35 N |
Installation orientation | any |
Insertion depth | 32 mm |
Mechanical life | 1 x 10⁶ |
Retention force | 50 N |
Switching principle | Slow-action switching contact |
Degree of protection | IP67 |
Ambient temperature | -20 ... +80 °C |
Material | |
Housing | Die-cast alloy cathodically dipped |
Contact | Silver alloy, gold flashed |
Locking force Fmax | 1700 N |
Locking force FZh | 1300 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
B10D | Mission time | |
---|---|---|
Monitoring of the guard position | 5x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V |
PL | Maximum SIL | Category | Mission time | |
---|---|---|---|---|
Control of guard locking | Depending on external control of guard locking | 20 y |
Miscellaneous
C number | |
C1991 |
In combination with actuator ACTUATOR-X-GQ
Overtravel | 1 mm |
In combination with actuator ACTUATOR-X-GNQ
Overtravel | 8 mm |
Similar products:
EUCHNER Safety switch TX3B-A024RC18C1991; 093559
Safety switch TX, plug connector M23 (RC18) Auxiliary release on the front Escape release on the rear side Release under load possible With door monitoring contact
-
(Out of stock)
Price on request
EUCHNER Safety switch TX3C-A024M; 082953
Safety switch TX, release under load Auxiliary release on the front Release under load possible With door monitoring contact
-
(Out of stock)
Price on request
EUCHNER Safety switch TX1B-A024N; 082944
Safety switch TX Auxiliary release on the front With door monitoring contact
-
(Out of stock)
Price on request
EUCHNER Safety switch TX1B-A024RC18; 082933
Safety switch TX, plug connector M23 (RC18) Auxiliary release on the front With door monitoring contact Plug connector M23 (RC18)
-
(Out of stock)
Price on request
EUCHNER Safety switch TX2B-A024M; 082927
Safety switch TX Auxiliary release on the front With door monitoring contact
-
(Out of stock)
Price on request
EUCHNER Safety switch TX2B-A024MC2093; 095618
Safety switch TX Auxiliary release on the front With door monitoring contact
-
(Out of stock)
Price on request