EUCHNER Transponder-coded safety switch CTA-L1-BP-U-HA-AP-SII-165454; 165454

EUCHNER Transponder-coded safety switch CTA-L1-BP-U-HA-AP-SII-165454; 165454

Transponder-coded safety switch CTA-BP, 2 x M12 Safety switch with guard locking and integrated evaluation electronics Direct connection to decentralized peripheral...

Brand: EUCHNER
Product Code: 165454
Availability: Check availability
Price on request

Transponder-coded safety switch CTA-BP, 2 x M12

  • Safety switch with guard locking and integrated evaluation electronics
  • Direct connection to decentralized peripheral systems (e.g. ET200pro)
  • Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Closed-circuit current principle
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With 2 plug connectors M12
  • Unicode
  • Door monitoring output
  • Approach directions A, B and C (delivery state)

Approvals

FCC_2AJ58-13c_UL_us_E155795_3/11

Workspace

Repeat accuracy R  
according to EN 60947-5-2 10 %

Electrical connection values

Fuse  
external (operating voltage UB) 0.25 ... 8 A
external (solenoid operating voltage IMP) 0.5 ... 8 A
Power consumption 6 W
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0.5 kV
Operating voltage DC  
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category  
DC-13 24 V 150 mA 
Solenoid operating voltage DC  
UIMP 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Risk time according to EN 60947-5-3 max. 270 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Switching load  
according to UL 24V DC, Class 2 
Safety class  
EN IEC 61140 III
Current consumption  
IUB 40 mA
IIMP 400 mA
Test pulse duration max. 0.3 ms 
Test pulse interval min. ca 100 ms
Degree of contamination (external, according to EN 60947-1) 3
  Monitoring output OD
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Switching current 1 ... 50 mA
  Safety outputs FO1A / FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage  
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
Discrepancy time  
both safety outputs max. 10 ms Acc. to EN IEC 60947-5-3
Turn-on time max. 150 ms
Off-state current Ir max. 0.25 mA
Switching current  
per safety output FO1A / FO1B 1 ... 150 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 2 plug connectors M12, 5-pin
Extraction force 20 N
Ready delay 5 s
Actuating force 10 N
Installation orientation any
Switching frequency max. 0.5 Hz
Mechanical life 1 x 10⁶
Overtravel 5 mm
Retention force 20 N
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65/IP67/IP69/IP69K 
Ambient temperature  
at UB = 24 V DC -20 ... +55 °C
Material  
Safety switch housing Die-cast zinc
Switch head cover Die-cast zinc
Locking force Fmax 8000 N
Locking force FZh 4000 N 
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
Category 4
Performance Level PL e
PFHD 5.38 x 10 -9

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions
Additional feature  
  Retrofit for escape release possible
  with blind flange

Similar products:


EUCHNER Transponder-coded safety switch CTA-L1-BP-U-HA-AP-SA-166702; 166702

Transponder-coded safety switch CTA-BP, M12 Safety switch with guard locking and integrated evaluation electronics Communication functions in combination with an
-
Need to order

(Out of stock)

Price on request

EUCHNER Transponder-coded safety switch CTA-L2-BP-U-HA-AP-SA-170659; 170659

Transponder-coded safety switch CTA-BP, M12 Safety switch with guard locking and integrated evaluation electronics Communication functions in combination with an
-
Need to order

(Out of stock)

Price on request

EUCHNER Transponder-coded safety switch CTS-C2-BP-CC-FLX-AP-VSA-169051; 169051

Transponder-coded safety switch CTS-C2-BP with FlexFunction, M12 Up to category 4 / PL e according to EN ISO 13849-1 Guard locking suitable for process protection
-
Need to order

(Out of stock)

Price on request

EUCHNER Transponder-coded safety switch CTM-LBI-BR-U-AZ-SP-166091; 166091

Transponder-coded safety switch CTM-LBI-BR, M12 Safety switch with guard locking and integrated evaluation electronics Series connection possible Communication functions
-
Need to order

(Out of stock)

Price on request

EUCHNER Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 ; 124987

Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 (closed-circuit current principle) Safety switch with guard locking and integrated evaluation
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CET-AR-..., RC18, with escape release ; 110943

Non-contact safety switch CET-AR-..., RC18, with escape release Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N
-
Need to order

(Out of stock)

Price on request

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products