EUCHNER Transponder-coded safety switch CTP-L1-AR-U-HA-AZ-SH-123362; 123362
Transponder-coded safety switch CTP-AR, M23 Safety switch with guard locking and integrated evaluation electronics Up to 20 switches in series Short circuit monitoring...
Price on request
Transponder-coded safety switch CTP-AR, M23
- Safety switch with guard locking and integrated evaluation electronics
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector M23
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)
Approvals
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | 10 % |
Electrical connection values
Fuse | |
external (solenoid operating voltage IMP) | 0.5 ... 8 A |
external (operating voltage UB) | 0.25 ... 8 A |
Power consumption | 6 W |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
Operating voltage DC | |
UUB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Utilization category | |
DC-13 | 24 V 150 mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV |
Solenoid duty cycle | 100 % |
Risk time according to EN 60947-5-3 | max. 260 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 5 ms |
Switching load | |
according to UL | 24V DC, Class 2 |
Safety class | |
EN IEC 61140 | III |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Test pulse duration | max. 1.0 ms |
Test pulse interval | min. 140 ms |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output OD, OI, OL | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8xUB ... UB V DC |
Switching current | 1 ... 50 mA |
Safety outputs FO1A / FO1B | |
Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
HIGH U(FO1A) / U(FO1B) | UB-1.5 ... UB V DC |
Discrepancy time | |
both safety outputs | max. 10 ms Acc. to EN IEC 60947-5-3 |
Turn-on time | max. 400 ms |
Off-state current Ir | max. 0.25 mA |
Switching current | |
per safety output FO1A / FO1B | 1 ... 150 mA |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | 1 plug connector M23, 19-pin, RC18 |
Extraction force | 20 N |
Ready delay | 8 s |
Actuating force | 10 N |
Installation orientation | any |
Switching frequency | max. 0.5 Hz |
Mechanical life | 1 x 10⁶ |
Overtravel | 5 mm |
Retention force | 20 N |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67 |
Ambient temperature | |
at UB = 24 V DC | -20 ... +55 °C |
Material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Reinforced thermoplastic |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10 -9 |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Similar products:
EUCHNER Transponder-coded safety switch CTP-L1-AR-U-HA-AEE-SH-137164; 137164
Transponder-coded safety switch CTP-AR, M23, emergency stop, 2 pushbuttons (extended), with escape release Safety switch with guard locking and integrated evaluation
-
(Out of stock)
Price on request
EUCHNER Transponder-coded safety switch CTP-L1-AR-U-HA-AZE-SH-126874; 126874
Transponder-coded safety switch CTP-AR, M23, emergency stop, 2 pushbuttons (extended) Safety switch with guard locking and integrated evaluation electronics Up to
-
(Out of stock)
Price on request
EUCHNER Transponder-coded safety switch CTP-L1-AR-U-HA-AE-SAB-122813; 122813
Transponder-coded safety switch CTP-L1-AR-U-HA-AE-SAB-122813, 2 x M12, with escape release; 122813 Safety switch with guard locking and integrated evaluation electronics
-
(Out of stock)
Price on request
EUCHNER Transponder-coded safety switch CTP-L1-AR-M-HA-AE-SAB-123308; 123308
Transponder-coded safety switch CTP-AR, 2 x M12, with escape release Safety switch with guard locking and integrated evaluation electronics Up to 20 switches in
-
(Out of stock)
Price on request
EUCHNER Transponder-coded safety switch CTP-L1-AR-M-HA-AZ-SAB-123307; 123307
Transponder-coded safety switch CTP-AR, 2 x M12 Safety switch with guard locking and integrated evaluation electronics Up to 20 switches in series Short circuit
-
(Out of stock)
Price on request
EUCHNER Transponder-coded safety switch CTP-L1-AR-M-HA-AZ-SH-123363; 123363
Transponder-coded safety switch CTP-AR, M23 Safety switch with guard locking and integrated evaluation electronics Up to 20 switches in series Short circuit monitoring
-
(Out of stock)
Price on request