EUCHNER Transponder-coded safety switch CTS-C1-BP-CC-FLX-AP-VSA-169052; 169052
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12 Up to category 4 / PL e according to EN ISO 13849-1 Closed-circuit current principle Connecting...
Price on request
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Closed-circuit current principle
- Connecting cable , PVC, 25 cm, plug connector M12, 8-pin
- Monitoring outputs OD/OL and OER
Approvals
Electrical connection values
Fuse | |
UB | 1 ... 8 A external |
IMP | 1 ... 8 A external |
Power consumption | 9 W |
rated conditional short-circuit current | 100 A |
Rated insulation voltage Ui | 32 V |
Rated impulse withstand voltage Uimp | 0.8 kV |
Operating voltage DC | |
UB | 24 V DC -15% ... +20% |
Discrepancy time | max. 10 ms |
Turn-on time | max. 400 ms |
EMC protection requirements | Acc. to EN 60947-5-3 |
Solenoid operating voltage DC | 24 V DC -15% ... +20% reverse polarity protected, regulated, residual ripple<5%, SELV |
Solenoid duty cycle | 100 % |
Risk time according to EN 60947-5-3 | max. 200 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
Switching load | |
according to UL | DC 24 V, class 2 |
Safety class | |
EN IEC 61140 | III |
Current consumption | |
IIMP | 500 mA |
IUB | 50 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring outputs Ox/C | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8xUB ... UB V DC |
Output current | |
I-configuration (guard lock monitoring inactive) | 1 ... 10 mA |
L configuration (guard lock monitoring active) | 1 ... 20 mA |
Safety outputs FO1A/FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-4V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
I-configuration (guard lock monitoring inactive) | 1 ... 75 mA |
L configuration (guard lock monitoring active) | 1 ... 80 mA |
Output current | |
per safety output FO1A / FO1B | |
Utilization category | |
DC-13 I configuration (guard lock monitoring inactive) | 24 V 75 mA |
DC-13 L configuration (guard lock monitoring active) | 24 V 80 mA |
Test pulse duration | max. 0.3 ms |
Test pulse interval | min. 96 ms |
Mechanical values and environment
Approach speed | max. 20 m/min |
Extraction force | 25 N |
Ready delay | max. 1 s |
Actuating force | 25 N |
Installation orientation | any |
Mechanical life | 1 x 10⁶ |
Retention force | 10 N |
Shock and vibration resistance | Acc. to EN 60947-5-3 |
Degree of protection | IP65/IP67/IP69/IP69K |
Ambient temperature | -20 ... +55 °C |
Material | |
Connecting cable | PVC |
Switch head cover | Die-cast zinc |
Safety switch housing | Reinforced thermoplastic |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Guard locking principle | Closed-circuit current principle |
Connection X1 | |
Connection type | Connecting cable with plug connector M12 |
Static bending radius | 8x cable diameter |
Cable outlet | straight |
Cable length | 0.25 m |
Number of pins | 8 |
Safety outputs FO1A/FO1B | |
Switching frequency | max. 0.2 Hz |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL e | 3 | 6.44x10-9 | 4 | 20 y |
Monitoring of guard locking | PL e | 3 | 6.44x10-9 | 4 | 20 y |
Only applies with active guard lock monitoring (guard locking for personal protection). Depending on the actuator used. |
PL | Maximum SIL | Category | Mission time | |
---|---|---|---|---|
Control of guard locking | Depending on external control of guard locking | 20 y |
Miscellaneous
<