EUCHNER Transponder-coded safety switch CTS-C2-BR-CC-FLX-AP-VAB-169613; 169613

EUCHNER Transponder-coded safety switch CTS-C2-BR-CC-FLX-AP-VAB-169613; 169613

Transponder-coded safety switch CTS-C2-BR with FlexFunction, 2 x M12 Up to category 4 / PL e according to EN ISO 13849-1 Guard locking suitable for process protection...

Brand: EUCHNER
Product Code: 169613
Availability: Check availability
Price on request

Transponder-coded safety switch CTS-C2-BR with FlexFunction, 2 x M12

  • Up to category 4 / PL e according to EN ISO 13849-1
  • Guard locking suitable for process protection only
  • Up to 20 switches in series
  • Open-circuit current principle
  • Connecting cable, PVC, 25 cm, plug connector 2 x M12
  • Monitoring outputs OD/OL

Approvals

FCC_CTS_2AJ58-18c_UL_us_E93776_5/1

Electrical connection values

Fuse  
UB 1 ... 8 A external
IMP 1 ... 8 A external
Power consumption 9 W
rated conditional short-circuit current 100 A
Rated insulation voltage Ui 32 V
Rated impulse withstand voltage Uimp 0.8 kV
Operating voltage DC  
UB 24 V DC -15% ... +20% 
   
Discrepancy time max. 10 ms
Turn-on time max. 400 ms
EMC protection requirements Acc. to EN 60947-5-3
Solenoid operating voltage DC 24 V DC -15% ... +20% reverse polarity protected, regulated, residual ripple<5%, SELV
Solenoid duty cycle 100 %
Risk time according to EN 60947-5-3 max. 200 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 10 ms
Switching load  
according to UL DC 24 V, class 2
Safety class  
EN IEC 61140 III
Current consumption  
IUB 50 mA
IIMP 500 mA
   
Degree of contamination (external, according to EN 60947-1) 3
  Monitoring output Ox/C
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Output current 1 ... 10 mA
  Safety outputs FO1A, FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage  
UFO1A /UFO1B LOW 0 ... 1 V DC
UFO1A /UFO1B HIGH UB-4V ... UB V DC 
Output current  
per safety output FO1A / FO1B 1 ... 75 mA
Utilization category  
DC-13 24 V 75 mA 
Test pulse duration max. 0.3 ms
Test pulse interval min. 96 ms

Mechanical values and environment

Approach speed max. 20 m/min
Extraction force 25 N
Ready delay max. 5 s
Actuating force 25 N
Installation orientation any
Mechanical life 1 x 10⁶
Retention force 10 N
Shock and vibration resistance Acc. to EN 60947-5-3
Degree of protection IP65/IP67/IP69/IP69K
Ambient temperature -20 ... +50 °C
Material  
Switch head cover Die-cast zinc
Safety switch housing Reinforced thermoplastic
Connecting cable PVC
Locking force Fmax 3900 N
Locking force FZh 3000 N
Guard locking principle Open-circuit current principle
  Connection X2
Connection type Connecting cable with plug connector M12
Static bending radius 8x cable diameter
Cable outlet straight
Cable length 0.25 m
Number of pins 5
  Connection X1
Connection type Connecting cable with plug connector M12
Static bending radius 8x cable diameter
Cable outlet straight
Cable length 0.25 m
Number of pins 8
  Safety outputs FO1A, FO1B
Switching frequency max. 0.2 Hz

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

  PL Maximum SIL PFHD Category Mission time
Monitoring of the guard position PL e 3 6.44x10-9 4 20 y

 

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Similar products:


EUCHNER Transponder-coded safety switch CTS-C1-BR-CC-FLX-AP-V05-169053; 169053

Transponder-coded safety switch CTS-C1-BR with FlexFunction, connecting cable with flying lead Up to category 4 / PL e according to EN ISO 13849-1 Up to 20 switches
-
Need to order

(Out of stock)

Price on request

EUCHNER Transponder-coded safety switch CTS-C1-BR-CC-FLX-AP-VAB-169612; 169612

Transponder-coded safety switch CTS-C1-BR with FlexFunction, 2 x M12 Up to category 4 / PL e according to EN ISO 13849-1 Up to 20 switches in series Closed-circuit
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CET1-AR-CRA-AH-50A-SG-106616; 106616

Non-contact safety switch CET-AR-..., M12, with escape release Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N
-
Need to order

(Out of stock)

Price on request

EUCHNER Variable magnetic guard locking device CEM-M2-C60-PZ-SE-161320; 161320

Variable magnetic guard locking device CEM-C60 with permanent magnet, plug connector on left Magnetic guard locking for process protection Guard locking solenoid
-
Need to order

(Out of stock)

Price on request

EUCHNER Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 ; 124987

Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 (closed-circuit current principle) Safety switch with guard locking and integrated evaluation
-
Need to order

(Out of stock)

Price on request

EUCHNER Non-contact safety switch CET-AR-..., RC18, with escape release ; 110943

Non-contact safety switch CET-AR-..., RC18, with escape release Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N
-
Need to order

(Out of stock)

Price on request

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products