Festo IO-Link Master USB CDSU-1 ; 8091509

Festo IO-Link Master USB CDSU-1 ; 8091509

Allows Festo IO-Link® products to be commissioned quickly and intuitively Compact, cost-effective, powerful Universal connections Galvanic isolation Connecting...

Brand: festo
Product Code: 8091509
Availability: Check availability
Price on request
  • Allows Festo IO-Link® products to be commissioned quickly and intuitively
  • Compact, cost-effective, powerful
  • Universal connections
  • Galvanic isolation
  • Connecting cables for almost all IO-Link® devices from Festo
  • For IO-Link® devices with protocol version 1.1 or 1.0
  • Supports data storage
USB interface
USB 2.0 type B, mini
USB interface, galvanic isolation
yes
Electric IO-Link® connection, connection pattern
00991867
USB interface, plug pattern
00995868
IO-Link®, data memory available
2 kByte/port
IO-Link®, number of ports
1
Short-circuit protection
yes
IO-Link®, output current
Max. input current with external supply (<2.5 A)
80 mA with USB operation
IO-Link®, process data width IN
0–32 bytes parameterizable
Overload protection
Not available
Power supply, function
Additional power supply
Electrical connection, IO-Link®, connection technology
M12x1, A-coded as per EN 61076-2-101
IO-Link®, communication mode
COM1 (4.8 kBd), COM2 (38.4 kBd), COM3 (230.4 kBd)
IO-Link®, process data width OUT
0–32 bytes parameterizable
Protocol
IO-Link®
IO-Link®, minimum cycle time
1.5 ms
Conforms to standard
EN 61131-9
Power supply, type of connection
Socket
Power supply, connection pattern
00995993
Reverse polarity protection
for operating voltage connections
Power supply, connection technology
Coaxial
IO-Link®, protocol version
Master V 1.1
Master V 1.0
Application note
for use with the USB IO-Link Master Tool software (available from the support portal) for Windows version 7 or above (32/64-bit).
IO-Link®, port class
A
B, with accessories
Electrical IO-Link® connection, connection type
Socket
Electrical connection IO-Link, occupied pins/wires
3
Electrical IO-Link® connection, number of pins/wires
5
Power supply, number of pins/wires
2
Output voltage
24 V DC ± 6 V with external supply (max. input voltage)
24 V DC ± 10% with USB operation
Input voltage
24 V DC ± 6 V via external supply
5 V DC at the USB connection
Power supply, information on connection technology
for plugs with exterior Ø 5.5 mm/interior-Ø 2.1 mm
Input current
Max. 2.5 V DC via external supply
Max. 600 mA at the USB connection
Type code
CDSU
CE marking (see declaration of conformity)
As per EU EMC directive
As per EU RoHS directive
Storage temperature
-10 °C ... 75 °C
Degree of protection
IP20
Ambient temperature
0 °C ... 55 °C
Certification
RCM compliance mark
Product weight
106 g
Note on materials
RoHS-compliant
Contains paint-wetting impairment substances
Housing material
Wrought aluminum alloy, anodized
  • 8091509datasheet

    8091509datasheet

  • CDSU-1 ENUS

    CDSU-1 ENUS



Similar products:


Festo Operator unit CDSB-A1 ; 8070984

The pluggable operating device is the compact display and operating unit for the servo drives CMMT and the automation system CPX-E. The colour touch screen allows
-
Need to order

(Out of stock)

Price on request

Festo Connection block CPX-P-AB-2XKL-8POL ; 565704

Individual components for the electrical terminal CPX-P
-
Need to order

(Out of stock)

Price on request

Festo Stepper module TAA-2N-PK-3-01-B ; 10535

For ensuring a logical program sequence Poppet valve with integrated AND as well as OR element
-
Need to order

(Out of stock)

Price on request

Festo Stepper module TAB-2N-PK-3-01-B ; 10536

For ensuring a logical program sequence Poppet valve with integrated AND as well as OR element
-
Need to order

(Out of stock)

Price on request

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products