The DeviceNet Slave bus coupler connects the DeviceNet bus to peripheral modules. As a group 2 server, the coupler supports the “Predefined Master/Slave Connection...
Out of stock
The DeviceNet Slave bus coupler connects the DeviceNet bus to peripheral modules. As a group 2 server, the coupler supports the “Predefined Master/Slave Connection Set” in accordance with sections 3-6 of the “CIP Networks Library Vol. 3.” In addition, the slave software, with the help of an “Unconnected Message Manager“ (UCMM), enables the dynamic setting up of multiple communications channels.
You can also choose from various combination possibilities for your I/O data and three kinds of DeviceNet connections: “Polled-I/O”, “Bit-Strobed-I/O,” and “COS/Cyclic-I/O.“ It is also equipped with a 2 kByte I/O data image table.
It recognizes all connected peripheral modules and assigns each module the inputs/outputs from the process image table.
Thanks to the TB20-ToolBox, it is easy to configure the system and the various module parameters and transfer them to the coupler.
A functioning TB20 configuration will always require a bus coupler and at least one peripheral module. The bus coupler supports hot-swapping for replacing modules during operation.
- Modules can be replaced during operation (hot-swapping)
- 24 V DC power supply
- Integrated power supply unit for powering peripheral modules (2.5 A)
- Supplies the system’s I/O voltage (24 VDC)
- USB device port for online diagnostics, configuring parameters, setup, and firmware updates with "TB20 ToolBox"
- TB20 ToolBox simulation for commissioning the I/O system without a higher-level controller in order to test the functionality (I/O check)
- Concealed "factory reset" switch for restoring the module to its factory settings
- Group 2 server
- UCMM-compatible
- Polled, Bit-Strobe, COS/Cyclic connections
- Supports Offline Connection Set, Device Heartbeat, and Device Shutdown messages
- MAC ID and transfer rates can be set via software and hardware (DIP switch)
- Supports 125, 250, and 500 kbps
- Up to 64 TB20 modules
- 1024 bytes of input data / 1024 bytes of output data
- 120 bytes of parameter data per module
- Modules can be freely configured via “TB20-ToolBox”
- Configuration with Rockwell RSNetWorx© possible using explicit messaging
- Reading out of coupler status possible using explicit messaging
- Six LEDs, four of them bi-color (three DeviceNet LEDs and one TB20-specific)
- Offers an Open Style Connector
General information | ||
---|---|---|
Order number | 600-165-1AA11 | |
Article name | TB20-C, DeviceNet Slave bus coupler | |
Scope of delivery | Bus coupler DeviceNet Slave, 24 V power supply connector, bus cover element, base module | |
Dimensions (DxWxH) | 110 x 35 x 73 mm | |
Weight | Approx. 115 g | |
DeviceNet interface | ||
Number | 1 | |
Protocol | DeviceNet | |
Transmission rate | 125, 250, and 500 kbps | |
I/O image size | 1024/1024 bytes | |
Parameters per module | 120 bytes | |
Connection | DeviceNet Open Connector | |
USB interface | ||
Number | 1 | |
Protocol | Full-speed USB 1.1 device | |
Connection | Mini-USB | |
Isolation voltage | 1.5 kV | |
Electrical isolation | Yes | |
Number of modules that can be connected in series | 64 | |
Voltage supply | 24 VDC, 18–28 VDC | |
Current draw | ||
Current draw without modules (internal) | 75 mA | |
Power supply for modules | 5 V DC, max 2.5 A | |
Power dissipation | Max. 8 W | |
Installation position | Any | |
Ambient conditions | ||
Ambient temperature | 0 °C … +60 °C | |
Transport and storage temperature | -20 °C … +80 °C | |
Relative air humidity | 95 % r H without condensation | |
Protection rating | IP 20 | |
Certifications | CE, UL pending | |
CE | ||
Noise immunity | DIN EN 61000-6-2 “EMC Immunity” | |
Interference emission | DIN EN 61000-6-4 “EMC Emission” | |
Vibration and shock resistance | DIN EN 60068-2-8:2008 “Vibration”, DIN EN 60068-27:2010 “Shock“ | |
RoHS | Yes | |
REACH | Yes |