Invertek Drives Optidrive Eco - Outdoor IP66 frequency drivers for pumps/fans
Invertek Drives Optidrive Eco - Outdoor IP66 frequency drivers for pumps/fans
-
Eco Vector Motor Control
-
Energy Optimised Design
-
Internal EMC filter
-
Low noise operation
INVERTEK DRIVES Optidrive Eco, Single Phase Input, 0.75 kW, 4.3 A, 200-240 V, IP66 Non Switched Outdoor; ODV-3-220043-1F1A-MN
(Out of stock)
INVERTEK DRIVES Optidrive Eco, 1.5 kW (2 HP), 7 A, 200-240 V, 1-3PH IP66 Non Switched Outdoor; ODV-3-220070-1F1A-MN
(Out of stock)
INVERTEK DRIVES Optidrive Eco; 0.75 kW (1 HP), 2.2 A, 380-480 V, 3PH IP66 Non Switched Outdoor, ODV-3-240022-3F1A-MN
(Out of stock)
INVERTEK DRIVES Optidrive Eco; 0.75 kW (1 HP), 4.3 A, 200-240 V, 1-3PH IP66 With Disconnect Outdoor, ODV-3-220043-1F1E-MN
(Out of stock)
INVERTEK DRIVES Optidrive Eco, 1.5 kW (2 HP), 4.1 A, 380-480 V, 3PH IP66 Non Switched Outdoor; ODV-3-240041-3F1A-MN
(Out of stock)
INVERTEK DRIVES Optidrive Eco, 2.2 kW (3 HP), 10.5 A, 200-240 V, 1-3PH IP66 Non Switched Outdoor; ODV-3-220105-1F1A-MN
(Out of stock)
INVERTEK DRIVES Optidrive Eco;1.5 kW (2 HP), 7 A, 200-240 V, 1-3PH IP66 With Disconnect Outdoor, ODV-3-220070-1F1E-MN
(Out of stock)
INVERTEK DRIVES Optidrive Eco; 0.75 kW (1 HP), 2.2 A, 380-480 V, 3PH IP66 With Disconnect Outdoor, ODV-3-240022-3F1E-MN
(Out of stock)
INVERTEK DRIVES Optidrive Eco,2.2 kW (3 HP), 5.8 A, 380-480 V, 3PH IP66 Non Switched Outdoor, ODV-3-240058-3F1A-MN
(Out of stock)
INVERTEK DRIVES Optidrive Eco; 1.5 kW (2 HP), 4.1 A, 380-480 V, 3PH IP66 With Disconnect Outdoor, ODV-3-240041-3F1E-MN
(Out of stock)
INVERTEK DRIVES Optidrive Eco; 2.2 kW (3 HP), 10.5 A, 200-240 V, 1-3PH IP66 With Disconnect Outdoor, ODV-3-220105-1F1E-MN
(Out of stock)
INVERTEK DRIVES Optidrive Eco; 2.2 kW (3 HP), 5.8 A, 380-480 V, 3PH IP66 With Disconnect Outdoor, ODV-3-240058-3F1E-MN
(Out of stock)
INVERTEK DRIVES Optidrive Eco; 4 kW (5 HP), 9.5 A, 380-480 V, 3PH IP66 Non Switched Outdoor,ODV-3-240095-3F1A-MN
(Out of stock)
INVERTEK DRIVES Optidrive Eco;4 kW (5 HP), 9.5 A, 380-480 V, 3PH IP66 With Disconnect Outdoor, ODV-3-240095-3F1E-MN
(Out of stock)
INVERTEK DRIVES Optidrive Eco; 5.5 kW (7.5 HP), 14 A, 380-480 V, 3PH IP66 Non Switched Outdoor, ODV-3-240140-3F1A-MN
(Out of stock)
Invertek Drives Optidrive Eco - Outdoor IP66 frequency drivers for pumps/fans
Optidrive Eco Features
A range of compact AC Variable Frequency Drives dedicated to pumping and HVAC systems.
- on board as standard
-
Multiple Pump Control
-
BACnet Interface
-
IP55 Enclosures
Dust-tight and ready to washdown.
-
In-built PID Controller
Accurately maintain pressure or temperature setpoint.
-
Control Modes
- Sensorless Vector Speed Control
- PM Vector Control
- BLDC Control
- Synchronous Reluctance
-
Sensorless Vector Control for all Motor Types
- Induction Motors (IM)
- Permanent Magnet Motors (PM)
- Brushless DC Motors (BLDC)
- Synchronous Reluctance Motors (SynRM)
- Line Start PM Motor (LSPM)
-
Options & Software
A range of external EMC filters, brake resistors, input chokes and output filters are available.
Installation Options -
Optistick Smart Compatible
Rapid commissioning tool.
Pump Control
- Controlling Your Pump System
- Optiflow Multi-pump Control
- Pump Staging Cascade Control
- Optimising Efficiency
- Hand / Auto
- Avoid Pump Downtime
- Blockage detect/clear
- Dry Run Protection
- Motor Preheat Function
- Pump Stir Cycle
- Pump Prime with Burst Pipe Detection
- Drive Controlled Bypass
HVAC Building Servies
- Controlling Your HVAC System
- Multiple Fan Operation
- Building Automation
- Optimising Efficiency
- Hand / Auto
- Belt Break Detection
- Noise Reduction
- Resonance Avoidance
- Drive Controlled Bypass
Embedded control technology for multiple pump systems
Building Automation
Comfortable safe & sustainable environment
Enclosure Options
Optidrive Eco is available in a range of IP20, IP55 & IP66/NEMA 4X enclosures.
Technical Specification
Input Ratings
Supply Voltage
380 – 480V ± 10%
500 – 600V ± 10%
Supply Frequency
Displacement Power Factor
Phase Imbalance
Inrush Current
Power Cycles
Output Ratings
Output Power
230V 3Ph. Input: 0.75–75kW (1–100HP)
400V 3Ph. Input: 0.75–250kW
460V 3Ph. Input: 1–350HP
575V 3Ph. Input: 0.75–110kW (1–150HP)
Overload Capacity
165% for 4 seconds
Output Frequency
Typical Efficiency
Ambient Conditions
Temperature
Operating : −10 to 50°C
Altitude
Up to 2000m maximum UL approved
Up to 4000m maximum (non UL)
Humidity
Vibration
Enclosure
Ingress Protection
Programming
Keypad
Optional remote mountable keypad
Display
PC
Control Specification
Control Method
Open Loop Permanent Magnet Vector
Open Loop BLDC Vector
Open Loop Synchronous Reluctance Vector
PWM Frequency
Stopping Mode
Coast to stop
Braking
Skip Frequency
Setpoint Control
Analog Signal
−10 Volts to +10 Volts
0 to 20mA / 20 to 0mA
4 to 20mA / 20 to 4mA
Digital
Modbus RTU
BACnet MS/TP
Fieldbus
Built in
BACnet MS/TP
9.6 - 76.8 kbps selectable
Data Format: 8N1, 8N2, 8O1, 8E1
Modbus RTU
Data Format: 8N1, 8N2, 8O1, 8E1
Optional
BACnet IP
Dual LAN ports
Device Level Ring
Other
PROFINET IO
DeviceNet
EtherNet/IP
EtherCAT
Modbus TCP
I/O Specification
Power Supply
10 Volt DC, 10mA for Potentiometer
Programmable Inputs
3 Digital (optional additional 3)
2 Analog / Digital selectable
Digital Inputs
8 – 30 Volt DC, internal or external supply
Response time < 4ms
Analog Inputs
Response time: < 4ms
Accuracy: < 1% full scale
Parameter adjustable scaling and offset
PTC Input
Trip Level : 3kΩ
Programmable Outputs
1 Analog / Digital
2 Relay
Relay Outputs
Switching Current Capacity: 5A
Analog Outputs
0 to 20mA / 20 to 0mA
4 to 20mA / 20 to 4mA
Application Features
PID Control
Multi Setpoint Select
Standby / Sleep Mode
Boost Function
Fire Mode
Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
Load Monitoring
Low Current Protection (Broken Belt / Shaft)
Pump Blockage Detection with Cleaning
Duty / Assist / Standby
Autotmatic Changeover on Fault
Automatic Changeover on Run Time
Fully Redundant
Pump Control Features
Pump Blockage Detection
Pump Cleaning
Multi-pump Control
Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
Pump Stir
Maintenance & Diagnostics
Fault Memory
Data Logging
Output Current
Drive Temperature
DC Bus Voltage
Maintenance Indicator
Onboard service life monitoring
Monitoring
Resettable & Non Resettable kWh meters
Cooling Fan Run Time
Standards Compliance
Low Voltage Directive
EMC Directive
Additional Conformance
Harmonic Currents
Environmental
IP55 & IP66 products: Designed for use in environments where the level of chemically active substances does not exceed the limits of class 3C3, and where the levels of mechanically active substances do not exceed the limits of class 3S3 according to IEC60721-3.