INVERTEK DRIVES Output filter OPT-2-M3180-00 ; 180A
Output filter, 180 A, IP20. Compact with Optidrive E3, P2 ,Eco , frame size 5 and 6. Reduce the rise time and peak voltage when long motor cables are used to protect...
VAT-exclusive price: 133.071,82 |
VAT-inclusive price: 159.686,19 |
Output filter, 180 A, IP20. Compact with Optidrive E3, P2 ,Eco , frame size 5 and 6.
- Reduce the rise time and peak voltage when long motor cables are used to protect the motor
- Reduce the dv/dt of the output waveform
Part Number |
Optidrive Size |
Connection |
L (mm) |
H (mm) |
B (mm) |
N1 (mm) |
N2 (mm) |
ØD (mm) |
Rated Volts |
Rated Amps |
Inductance (mH) |
Weight (kg) |
OPT-2-M3008-20 | 1 | 2.5 mm2 | 95 | 107 | 61 | 56 | 43 | 4 |
500 Max |
8 | 2.0 | 1.5 |
OPT-2-M3012-20 | 2 | 4 mm2 | 125 | 158 | 76 | 100 | 55 | 5 | 12 | 1.7 | 2.8 | |
OPT-2-M3030-20 | 3 | 10 mm2 | 155 | 185 | 66 | 130 | 57 | 8 | 30 | 0.5 | 4.2 | |
OPT-2-M3075-20 | 4 & 5 | 35 mm2 | 190 | 223 | 92 | 170 | 68 | 8 | 75 | 0.22 | 8.6 | |
OPT-2-M3180-00 | 5 & 6 | 11 mm | 360 | 263 | 180 | 264 | 122 | 10 x 18 | 400 Max | 180 | 0.09 | 30 |
OPT-2-M3300-00 | 7 | 9 mm | 380 | 310 | 180 | 248 | 139 | 10 x 18 | 300 | 0.053 | 48 |
Similar products:
INVERTEK DRIVES Output filter OPT-2-M3008-20 ; 8A
Output filter, 8A, IP20. Compact with Optidrive E3, P2 ,Eco , frame size 1. Reduce the rise time and peak voltage when long motor cables are used to protect the
-
(Out of stock)
21.849,46
INVERTEK DRIVES Output filter OPT-2-M3012-20 ; 12A
Output filter, 12A, IP20. Compact with Optidrive E3, P2 ,Eco , frame size 2. Reduce the rise time and peak voltage when long motor cables are used to protect the
-
(Out of stock)
35.057,88
INVERTEK DRIVES Output filter OPT-2-M3030-20 : 30A
Output filter, 30A, IP20. Compact with Optidrive E3, P2 ,Eco , frame size 3. Reduce the rise time and peak voltage when long motor cables are used to protect the
-
(Out of stock)
53.574,37
INVERTEK DRIVES Output filter OPT-2-M3075-20 ; 75A
Output filter, 75A, IP20. Compact with Optidrive E3, P2 ,Eco , frame size 4 and 5. Reduce the rise time and peak voltage when long motor cables are used to protect
-
(Out of stock)
89.372,91
INVERTEK DRIVES Output filter OPT-2-M3300-00 ; 300A
Output filter, 300A, IP20. Compact with Optidrive E3, P2 ,Eco , frame size 7. Reduce the rise time and peak voltage when long motor cables are used to protect the
-
(Out of stock)
252.441,45
INVERTEK DRIVES Input Choke, 3 phase, 90 Amp, IP20
Input Choke, three phase, rated current 90A ; IP20 Reduce power supply harmonic currents Reduce the overall input current to the drive Provide additional protection
-
(Out of stock)
146.774,02