Klemsan Multimetar ECRAS 220 ; 606213
Multimeter ECRAS by KLEMSAN is an advanced multimeter that can measure 3 phases in electric networks and can be controlled by 2 relay outputs. ECRAS offers a very...
VAT-exclusive price: 16.459,92 |
VAT-inclusive price: 19.751,91 |
Multimeter ECRAS by KLEMSAN is an advanced multimeter that can measure 3 phases in electric networks and can be controlled by 2 relay outputs. ECRAS offers a very precise measurements of basic electrical network. All measured data can be transferred to the remote monitoring system via modbus communication. Low/high limit threesold values for all electrical parameters can be defined and assigned to alarm relay outputs.
General | Seven Segment Display | ✔ | |
Password Protection | ✔ | ||
Current Transformer Ratio | 1 - 5000 | ||
Voltage Transformer Ratio | 1 - 5000 | ||
Demand Period | 1-60 min. adjustable | ||
Connection Type | 3F4T, 3F3T | ||
Measurements in Quadrants | 4 | ||
Number of Measurements in a Period | 256 | ||
LCD/Display Refresh Period | 1 sec. | ||
Networks | TT, TN, IT | ||
Min./Max./Demand Values | ✔ | ||
Energy Measurement | Number of Tariffs | 1 | |
1Ø Phase Energy Meters | ✔ | ||
3Ø Phase Energy Meters | ✔ | ||
Current Measurement Input | Measurement Range | 10mA - 6A AC | |
Overvoltage Category | 300 V Cat II | ||
Measurement Surge Voltage | 2 kV | ||
Power Consumption | <0.2 VA | ||
Intermittent Overload | 100 A for 1 sec. | ||
Sampling Frequency between 45-65 Hz | 12.8 kHz | ||
Voltage Measurement Input | Overvoltage Category | 300 V Cat III | |
Measured Range L-N | 1-300 Vrms | ||
Measured Range L-L | 2-500 Vrms | ||
Measured Frequency Range | 45-65 Hz | ||
Power Consumption | <0.1 VA | ||
Sampling Frequency between 45-65 Hz | 12.8 kHz | ||
Power Quality Measurements | Harmonics for Current and Voltage Phases | Up to 31st | |
THD - Voltage in % | ✔ | ||
THD - Current in % | ✔ | ||
Other Measurements | Run Hour (Operating Time for Load in Hours) | ✔ | |
On Hour (Operating Time for Meter in Hours) | ✔ | ||
Int Counter (Number of Power Interruptions) | ✔ | ||
Measurement Accuracy | According to IEC 61557-12 | Total Active Power | Class 0.5 |
Total Reactive Power | Class 1 | ||
Total Apparent Power | Class 0.5 | ||
Total Active Energy | Class 0.5 | ||
Total Reactive Energy | Class 2 | ||
Frequency | Class 0.1 | ||
Current | Class 0.5 | ||
Neutral Current | Class 0.5 | ||
Voltage | Class 0.2 | ||
Power Factor | Class 0.5 | ||
THDV, THDI | Class 1 | ||
According to IEC 62053-22 | Total Active Energy | Class 0.5S | |
According to IEC 62053-23 | Total Reactive Energy | Class 2 | |
Inputs and Outputs | Alarm Relay Outputs | Number of Outputs | 2 |
Type | NO (SPST) | ||
Max. Switching Current | 10 A | ||
Max. Switching Voltage | 250 VAC | ||
Max. Switching Power | 1250 VA | ||
Supply | Voltage | AC | 85-300V |
DC | 85-300V | ||
Consumption | AC | <6VA | |
DC | <3W | ||
Supply | Frequency | 45-65Hz | |
Data Logging with timestamp | Min./Max./Avg. Values | Hourly Records | |
Daily Records | |||
Monthly Records | |||
Data Logging with timestamp | Demand | ||
Communication | Protocol | Modbus RTU | |
Baud Rate | 1200-57600 bps adjustable | ||
Parity Number | Odd, Even, None | ||
Stop Bit | 1 | ||
Address | 1-247 | ||
Isolation | 2750V RMS | ||
Mechanical Properties | Weight (g) | 316 g | |
Protection Class | Front IP40 / Rear IP20 | ||
Mounting Type | Panel Mount | ||
Cable Cross Sections | Supply, Voltage, Current, Relay Outputs | Stranded: | 2.5mm² - 14AWG |
Solid: | 4mm² - 12AWG, 2x1.5mm² - 2x16AWG | ||
Digital I/O, RS 485, Analog Output | Stranded: | 1.5mm² - 16AWG | |
Solid: | 1.5mm² - 16AWG, 2x0.75mm² - 2x18AWG | ||
Ambient Conditions | Operating Temperature | -20°C +70°C | |
Storing Temperature | -30°C +80°C | ||
Relative Humidity (No Condensation) | Max. 95% | ||
EMC-EMI | 300 VAC CAT II according to IEC 61010-1 | ✔ | |
EN 55011/A1:2010, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN61000-4-11 | ✔ | ||
Schematics | Network Connections | ||
Digital I/O and Alarm Output Connections | |||
3 wires with 3CTs | |||
4 wires with 3CTs | |||
3 wires with 2CTsNOTE: CTs can be connected any phase. They are connected to phase 1 and phase 3 in this figure. | |||
Single Phase with 1CTNORE: CT and VT can be connected any phase. They are connected to phase 1 in this figure. | |||
Digital Output Connection | |||
Digital Input Connection | |||
Alarm Output Connection | |||
Analog Output Connection |
Similar products:
Klemsan Multimetar ECRAS 120 ; 606211
Multimeter ECRAS by KLEMSAN is an advanced multimeter that can measure 3 phases in electric networks and can be controlled by 2 relay outputs. ECRAS offers a very
-
(In stock)
13.391,12
Klemsan Multimetar ECRAS 200 ; 606212
Multimeter ECRAS by KLEMSAN is an advanced multimeter that can measure 3 phases in electric networks and can be controlled by 2 relay outputs. ECRAS offers a very
-
(In stock)
15.344,00
Klemsan Multimetar ECRAS VCF ; 606218
Multimeter ECRAS by KLEMSAN is an advanced multimeter that can measure 3 phases in electric networks and can be controlled by 2 relay outputs. ECRAS offers a very
-
(In stock)
9.764,36
Klemsan Multimetar ECRAS 100 ; 606210
Multimeter ECRAS by KLEMSAN is an advanced multimeter that can measure 3 phases in electric networks and can be controlled by 2 relay outputs. ECRAS offers a very
-
(In stock)
12.833,16