Klemsan Power Factor Controller 232R 3phase ; 606002
RAPIDUS is a 3 phase Reactive Power Control Relay that capable of inductive and capacitive compensation. At the same time, with the energy measurements menu, it...
Price on request
RAPIDUS is a 3 phase Reactive Power Control Relay that capable of inductive and capacitive compensation. At the same time, with the energy measurements menu, it can perform detailed energy analysis. Dynamic capacitor monitoring allows continuous updating of step power values. Thanks to unique intelligent mode, it activates the step combination closest to the measured demand by calculating their lifetime.
A power factor controller RAPIDUS is an automation device which allows power distribution system to operate at its maximum efficiency with reducing reactive power. This control process reduces the load requirement on the energy generation and transmission supply system.
A power factor controller RAPIDUS is an automation device which allows power distribution system to operate at its maximum efficiency with reducing reactive power. This control process reduces the load requirement on the energy generation and transmission supply system.
- Modular design
- No socket cable required
- Dynamic capacitator monitoring
- The latest technology
- Learning connections and step powers
- Modbus communication
General | Measuring system | 3Ø | |
LCD Screen | ✔ | ||
Language Support | Turkish, English, Russian | ||
Battery | ✔ | ||
Real Time Clock | ✔ | ||
Password Protection | ✔ | ||
Current Transformer Ratio | 1 - 5000 | ||
Voltage Transformer Ratio | 1 - 5000 | ||
Demand Period | 1-60 min. adjustable | ||
Connection Type | 3F4T | ||
Measurement in Quadrants | 4 | ||
Number of Measurements in a Period | 512 | ||
LCD/Display Refresh Period | 1 sec. | ||
Networks | TT, TN, IT | ||
Phasor Diagram | Available | ||
Min./Max./Demand Values | ✔ | ||
Control Operations and Functions | Compensation Modes | Rapidus (Intelligent control mode) | ✔ |
Sequential | ✔ | ||
Linear | ✔ | ||
Circular | ✔ | ||
Manual | ✔ | ||
Step Configurations | Manually Assigned | ✔ | |
Predefined | 1-1-1-1, 1-1-2-2, 1-2-2-4, 1-2-3-3, 1-2-4-4, 1-1-2-4, 1-2-3-4, 1-2-4-8, 1-1-2-3 | ||
DCM | ✔ | ||
Fixed Step Assigment | ✔ | ||
Power (kVAr) | ✔ | ||
Type | 3Ø capacitor, 3Ø shunt reactor adjustable | ||
Power Factor Settings | Target 1 cosØ | 0.8 cap. to 0.8 ind. adjustable | |
Target 2 cosØ | 0.8 cap. to 0.8 ind. adjustable | ||
Control Operations and Functions | Learning Step Powers and Connections | ✔ | |
Dual cosØ Target | ✔ | ||
4 Quadrant operation for generators | ✔ | ||
Time Delays | Step Activation Time | 1-600 sec. adjustable | |
Step Deactivation Time | 1-600 sec. adjustable | ||
Step Discharge Time | 3-1000 sec. adjustable | ||
Control Operations and Functions | Phase Shift Angle | ±45 degree adjustable | |
Averaging Time | ±45 degree adjustable | ||
Energy Measurement | Number of Tariffs | 1 | |
3Ø Phase Energy Meters | Available | ||
Current Measurement Input | Measurement Range | 10mA-6A AC | |
Overvoltage Category | 300 V Cat II | ||
Measurement Surge Voltage | 2 kV | ||
Power Consumption | <0.2 VA | ||
Intermittent Overload | 100A for 1 sec. | ||
Sampling Frequency between 45-65 Hz | 25.6 kHz | ||
Voltage Measurement Input | Overvoltage Category | 300 V Cat III | |
Measured Range L-N | 95-272 VAC ±10% | ||
Measured Range L-L | 164-471 VAC ±10% | ||
Measured Frequency Range | 45-65 Hz | ||
Power Consumption | <0.1 VA | ||
Sampling Frequency between 45-65 Hz | 25.6 kHz | ||
Power Quality Measurements | Harmonics for Current and Voltage Phases | Up to 51st | |
THD - Voltage in % | ✔ | ||
THD - Current in % | ✔ | ||
Measurement Accuracy | According to IEC 61557-12 | Total Active Power | Class 0.2 |
Total Reactive Power | Class 1 | ||
Total Apparent Power | Class 0.2 | ||
Total Active Energy | Class 0.5 | ||
Total Reactive Energy | Class 2 | ||
Frequency | Class 0.05 | ||
Current | Class 0.2 | ||
Neutral Current | Class 0.5 | ||
Voltage | Class 0.2 | ||
Power Factor | Class 0.5 | ||
THDV, THDI | Class 1 | ||
According to IEC 62053-22 | Total Active Energy | Class 0.2S | |
According to IEC 62053-23 | Total Reactive Energy | ||
Input and Outputs | Compensation Relay Outputs | Number of outputs | 24 |
Type | NO (SPST) | ||
Max. Switching Current | 2A | ||
Max. Switching Voltage | 250VAC | ||
Max. Switching Power | 1250VA | ||
Mechanical Lifetime | ≥ 10.0000000 operations | ||
Electrical Lifetime Operations (for NO side) | 5×104(5A@250VAC) 1×105(5A@30VDC) | ||
Alarm Relay Outputs | Number of outputs | 2 | |
Type | NO (SPST) | ||
Max. Switching Current | 4 A | ||
Max. Switching Voltage | 250 VAC | ||
Max. Switching Power | 1250 VA | ||
Mechanical life time | ≥ 10.0000000 operations | ||
Electrical life time operations (for NO side) | 5×104(5A@250VAC) 1×105(5A@30VDC) | ||
Generator/ Day-Night Input | Number of Inputs | 1 | |
Frequency | 45-65Hz | ||
Input Present or Not | 95-240VAC | ||
Input and Outputs | Digital Outputs | --- | |
Analog Outputs | --- | ||
Supply | Auxilary Supply Input | --- | |
Voltage | L1-N'den ±10% 95-272VAC | ||
Frequency | 45-65Hz | ||
Supply | Consumption | AC | < 10VA |
DC | --- | ||
Data Logging with timestamp | Min./Max./Avg. Values | Hourly Records | 1920 Hours x 68 Different Paramaters |
Daily Records | 240 Days x 68 Different Paramaters | ||
Monthly Records | 36 Months x 68 Different Paramaters | ||
Data Logging with timestamp | Demand | 4 Months x 16 Different Parameters | |
Alarm records | 50 | ||
Communication | Protocol | Modbus RTU | |
Baud rate | 2400-115200 bps adjustable | ||
Parity number | --- | ||
Stop bit | 1 | ||
Address | 1-247 | ||
Isolation | 2000V RMS | ||
Mechanical Properties | Weight (g) | 670g | |
Protection Class | Front IP40 / Rear IP20 | ||
Mounting Type | Panel Mount | ||
Packing Unit | 1 | ||
Cable Cross Sections | Voltage, Current, All Relay Outputs, Gen Input | Stranded: | 2.5mm² - 14AWG |
Solid: | 4mm² - 12AWG, 2x1.5mm² - 2x16AWG | ||
RS 485 | Stranded: | 1.5mm² - 16AWG | |
Solid: | 1.5mm² - 16AWG, 2x0.75mm² - 2x18AWG | ||
Ambient Conditions | Operating Temperature | -20°C +55°C | |
Storing Temperature | -30°C +80°C | ||
Relative Humidity (no condensation) | Maks. 95% | ||
EMC-EMI | EN 61000-6-1:2011 | ✔ | |
EN 61000-6-3/A1/ AC:2013 | ✔ | ||
Schematics | Network Connections | ||
Step Output Connections | |||
Digital I/O and Alarm Output Connections |
Similar products:
Klemsan Power Factor Controller 231R 3phase ; 606001
RAPIDUS is a 3 phase Reactive Power Control Relay that capable of inductive and capacitive compensation. At the same time, with the energy measurements menu, it
-
(Out of stock)
Price on request
Klemsan Power Factor Controller 116R 1phase ; 606063
RAPIDUS 1 series is a monophase Reactive Power Control Relay. It has 4, 6, 8, 10 and 12-steps options and an optional RS485 port. The built-in temperature sensor
-
(Out of stock)
Price on request
Klemsan Power factor Controller 111R 1 phase ; 606073
RAPIDUS 1 series is a monophase Reactive Power Control Relay. It has 4, 6, 8, 10 and 12-steps options and an optional RS485 port. The built-in temperature sensor
-
(Out of stock)
Price on request
Klemsan Power Factor Controller 231R 3phase ; 606001
RAPIDUS is a 3 phase Reactive Power Control Relay that capable of inductive and capacitive compensation. At the same time, with the energy measurements menu, it
-
(Out of stock)
Price on request
Klemsan Power Factor Controller 218R 1 phase ; 606021
RAPIDUS is a 3 phase Reactive Power Control Relay that capable of inductive and capacitive compensation. At the same time, with the energy measurements menu, it
-
(Out of stock)
Price on request