Multifunctional Gate Box


Search by features
Sort products by
Brand
  • 361
Price up to
In stock
  • 0
GUARD LOCKING DEVICE
  • 4
  • 1
  • 309
  • 47
HINGE POSITION
  • 11
  • 157
  • 193
DESIRED CONNECTION
  • 7
  • 137
  • 176
  • 18
  • 15
  • 4
  • 4
CATEGORY
  • 4
  • 86
  • 267
  • 2


Multifunctional Gate Box


MGB-AP for use as a single device; MGB-AR for series connection up to 10 MGB-AR devices; MGB-PN for Profinet connection; MGB Ethernet/IP for Ethernet connection.

EUCHNER Locking set MGB-L1H-APA-L-117069; 117069

Locking set MGB-L1H-APA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. adhesive labels, RC18 Guard locking with guard lock monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking module MGB-L2-ARA-BK5A1-M-L-121008; 121008

Locking module MGB-L2-ARA... (guard locking by solenoid force) with 1 pushbutton, incl. label carrier, guard lock monitoring switched off Guard locking with guard
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking module MGB-L1-ARA-AM5A1-S1-L-121217; 121217

Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking module MGB-L1-APA-AP5A1-S1-L-121378; 121378

Locking module MGB-L1-APA... (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking module MGB-L2-ARA-AM3A1-M-R-121257; 121257

Locking module MGB-L2-ARA... (guard locking by solenoid force) with 2 pushbuttons, emergency stop, incl. label carrier Guard locking with guard lock monitoring Can
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking module MGB-L1-ARA-AL3A1-S8-R-157884; 157884

Locking module MGB-L1-ARA... (guard locking by spring force) with 1 pushbutton, emergency stop, M12 for enabling switch, RC26 Guard locking with guard lock monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Interlocking set MGB-L0H-APA-L-110551; 110551

Interlocking set MGB-L0H-APA..., with 3 push buttons, incl. label carrier, M12 for enabling switch Locking (without guard locking) 3 pushbuttons (illuminated, wh,
-
Need to order

(Out of stock)

Price on request

EUCHNER Interlocking set MGB-L0HE-APA-L-112602; 112602

Interlocking set MGB-L0HE-APA..., without controls or indicators, RC18, on mounting plates Locking (without guard locking) With plug connector RC18 Mounted on mounting
-
Need to order

(Out of stock)

Price on request

EUCHNER Interlocking set MGB-L0HE-APA-R-112600; 112600

Interlocking set MGB-L0HE-APA..., without controls or indicators, RC18, on mounting plates Locking (without guard locking) With plug connector RC18 Mounted on mounting
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L1H-APA-L-114238; 114238

Locking set MGB-L1H-APA..., (guard locking by spring force) with 3 push buttons, M12 for enabling switch, RC18 Guard locking with guard lock monitoring 3 pushbuttons
-
Need to order

(Out of stock)

Price on request

EUCHNER Escape release MGB-E-A-100465; 100465

Escape release MGB-E-A-100465; 100465 Escape release MGB-E-A... Escape release from the danger zone Signal red door handle Extended actuation axis for thicker doors
-
Need to order

(Out of stock)

Price on request

EUCHNER Handle module MGB-H... with automatically extending lockout mechanism MGB-H-AA1A3-L ; 111158

Handle module MGB-H... with automatically extending lockout mechanism MGB-H-AA1A3-L ; 111158 Intelligent bolt tongue Fold-out lockout mechanism Second automatically
-
Need to order

(Out of stock)

Price on request

EUCHNER Handle module MGB-H-AA1A1-L ; 106619

Handle module MGB-H-AA1A1-L ; 106619 Intelligent bolt tongue Lockout mechanism Door handle
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L2H-ARA-L-110616 (guard locking by solenoid force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18

Locking set MGB-L2H-ARA-L-110616 (guard locking by solenoid force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18 ; 110616 Guard locking with guard
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking module MGB-L1-ARA-AA2A1-S1-L ; 110793

Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18; 110793 Guard locking and guard lock monitoring
-
Need to order

(Out of stock)

Price on request


Page 24 od 25
Showing 346 - 360 od 361 data

Multifunctional Gate Box


The MGB is a safety system with guard locking and guard lock monitoring for the protection of safety doors on machines and installations.

Economical, standard-compliant wiring

The family MGB-AP is particularly suitable for the protection of individual safety doors. If series connection is not necessary, wiring can then be saved. This version has different timing to the AR version.
All devices in the family MGB-AR can be wired directly in series in a so-called AR series connection without reducing safety or the PL. As a consequence evaluation units are saved.
AR devices are also available in the EUCHNER series CES and CET.

Seamless integration by means of bus connection

In the PROFINET version, MGB-PN, we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary PROFINET input and output bytes required. Comprehensive diagnostic information in the form of PROFINET messages makes troubleshooting quick and specific. Due to the typical ease with which parameters can be set in PROFINET, even the replacement of the system in case of servicing is a simple matter and can be undertaken in a few minutes.

In the MGB Ethernet/IP™ version, we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary CIP Safety input and output bytes required. Whether interlocking, guard locking, escape release or other functions such as buttons for start/stop, emergency stop, selector switch, etc. – the MGB meets all requirements for safety-related applications and can be equipped on a customer-specific basis. Comprehensive diagnostic information in the form of Ethernet/IP™ messages provides a fast and detailed overview of the device status. Due to the ease with which parameters can be set, even replacing the system during servicing is a simple matter and takes no more than a few minutes.


ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products