Multifunctional Gate Box
Search by features
Multifunctional Gate Box
MGB-AP for use as a single device; MGB-AR for series connection up to 10 MGB-AR devices; MGB-PN for Profinet connection; MGB Ethernet/IP for Ethernet connection.
EUCHNER Interlocking set MGB-L0H-ARA-R-124258; 124258
Interlocking set MGB-L0H-ARA..., with 2 pushbuttons, incl. label carrier, RC18 Interlocking (without guard locking) Can be connected in series with other AR devices
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L1-ARA-AD4A1-S1-L-110873; 110873
Locking module MGB-L1-ARA... (guard locking by spring force) with 3 pushbuttons, incl. label carrier, RC18 Guard locking with guard lock monitoring Can be connected
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L1-ARA-AA8A1-S1-R-111653; 111653
Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, incl. label carrier, RC18 Guard locking with guard lock monitoring Can be connected
-
(Out of stock)
Price on request
EUCHNER Locking set MGB-L2H-ARA-L-121264; 121264
Locking set MGB-L2H-ARA... (guard locking by solenoid force) with 2 pushbuttons, emergency stop, incl. label carrier Guard locking with guard lock monitoring Can
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L2C-ARA-R-112529; 112529
Locking module MGB-L2-ARA... (guard locking by solenoid force) with 3 pushbuttons, 2 indicators, emergency stop, incl. label carrier, RC26 Guard locking with guard
-
(Out of stock)
Price on request
EUCHNER Locking set MGB-L1HE-ARA-R-110220; 110220
Locking set MGB-L1HE-ARA..., (guard locking by spring force) with 2 pushbuttons, emergency stop Guard locking with guard lock monitoring Can be connected in series
-
(Out of stock)
Price on request
EUCHNER Locking set MGB-L1HE-ARA-L-121193; 121193
Locking set MGB-L1HE-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L1C-ARA-L-156859; 156859
Locking module MGB-L1-ARA..., (guard locking by spring force) with 5 pushbuttons, emergency stop, incl. label carrier, RC26 Guard locking with guard lock monitoring
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L1-ARA-AM5A1-S1-L-121217; 121217
Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L1-ARA-AP7A1-M-R-121404; 121404
Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbutton, emergency stop, selector switch Guard locking with guard lock monitoring Can be
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L1-ARA-AL3A1-S8-R-157884; 157884
Locking module MGB-L1-ARA... (guard locking by spring force) with 1 pushbutton, emergency stop, M12 for enabling switch, RC26 Guard locking with guard lock monitoring
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L1-APA-AP4A1-S1-L-121370; 121370
Locking module MGB-L1-APA... (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L1-APA-AG8A1-S1-L-115668; 115668
Locking module MGB-L1-APA.. (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-
(Out of stock)
Price on request
EUCHNER Locking set MGB-L1H-APA-R-110587; 110587
Locking set MGB-L1H-APA... (guard locking by spring force) with 3 pushbuttons, incl. label carrier, M12 for enabling switch Guard locking with guard lock monitoring
-
(Out of stock)
Price on request
EUCHNER Locking set MGB-L1H-ARA-R-121509; 121509
Locking set MGB-L1H-ARA..., (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier Guard locking with guard lock monitoring Can
-
(Out of stock)
Price on request
Multifunctional Gate Box
The MGB is a safety system with guard locking and guard lock monitoring for the protection of safety doors on machines and installations.
Economical, standard-compliant wiring
The family MGB-AP is particularly suitable for the protection of individual safety doors. If series connection is not necessary, wiring can then be saved. This version has different timing to the AR version.All devices in the family MGB-AR can be wired directly in series in a so-called AR series connection without reducing safety or the PL. As a consequence evaluation units are saved.
AR devices are also available in the EUCHNER series CES and CET.
Seamless integration by means of bus connection
In the PROFINET version, MGB-PN, we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary PROFINET input and output bytes required. Comprehensive diagnostic information in the form of PROFINET messages makes troubleshooting quick and specific. Due to the typical ease with which parameters can be set in PROFINET, even the replacement of the system in case of servicing is a simple matter and can be undertaken in a few minutes.In the MGB Ethernet/IP™ version, we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary CIP Safety input and output bytes required. Whether interlocking, guard locking, escape release or other functions such as buttons for start/stop, emergency stop, selector switch, etc. – the MGB meets all requirements for safety-related applications and can be equipped on a customer-specific basis. Comprehensive diagnostic information in the form of Ethernet/IP™ messages provides a fast and detailed overview of the device status. Due to the ease with which parameters can be set, even replacing the system during servicing is a simple matter and takes no more than a few minutes.