Multifunctional Gate Box
Search by features
Multifunctional Gate Box
MGB-AP for use as a single device; MGB-AR for series connection up to 10 MGB-AR devices; MGB-PN for Profinet connection; MGB Ethernet/IP for Ethernet connection.
EUCHNER Locking module MGB-L1-ARA-AM3A1-M-L-121261; 121261
Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier Guard locking with guard lock monitoring Can
-
(Out of stock)
Price on request
EUCHNER Interlocking set MGB-L0HE-ARA-R-111938; 111938
Interlocking set MGB-L0HE-ARA... without controls or indicators, RC18 Interlocking (without guard locking) Can be connected in series with other AR devices (e.g.
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L2-ARA-AM3A1-M-R-121237; 121237
Locking module MGB-L2-ARA... (guard locking by solenoid force) with 2 pushbuttons, emergency stop Guard locking with guard lock monitoring Can be connected in series
-
(Out of stock)
Price on request
EUCHNER Locking set MGB-L1H-ARA-R-121209; 121209
Locking set MGB-L1H-ARA..., (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC26 Guard locking with guard lock monitoring
-
(Out of stock)
Price on request
EUCHNER Interlocking set MGB-L0H-ARA-R-110955; 110955
Interlocking set MGB-L0H-ARA..., with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Interlocking (without guard locking) Can be connected in series with
-
(Out of stock)
Price on request
EUCHNER Locking set MGB-L1HE-APA-R-122089; 122089
Locking set MGB-L1HE-APA... (guard locking by spring force) with 3 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L1C-ARA-L-156859; 156859
Locking module MGB-L1-ARA..., (guard locking by spring force) with 5 pushbuttons, emergency stop, incl. label carrier, RC26 Guard locking with guard lock monitoring
-
(Out of stock)
Price on request
EUCHNER Locking set MGB-L2...-PN (guard locking by solenoid force) with 5 buttons, 7/8'' and M12 plugs, MGB-L2HEB-PNA-R-161483
Guard locking with guard lock monitoring Emergency stop according to ISO 13850, illuminated 4 illuminated pushbuttons including adhesive labels Connection via 7/8"
-
(Out of stock)
Price on request
EUCHNER Locking set MGB-L1H-APA-R-121369; 121369
Locking set MGB-L1H-APA... (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L1-ARA-AP7A1-M-R-121404; 121404
Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbutton, emergency stop, selector switch Guard locking with guard lock monitoring Can be
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L2-ARA-AL2A1-M-R-121064; 121064
Locking module MGB-L2-ARA... (guard locking by solenoid force) with 2 pushbuttons Guard locking with guard lock monitoring Can be connected in series with other
-
(Out of stock)
Price on request
EUCHNER Locking set MGB-L2HE-ARA-R-110820; 110820
Locking set MGB-L2HE-ARA... (guard locking by solenoid force) with 3 pushbuttons, RC18 Guard locking with guard lock monitoring Can be connected in series with other
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L2-ARA-AB8A1-S1-L-117313; 117313
Locking module MGB-L2-ARA... (guard locking by solenoid force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-
(Out of stock)
Price on request
EUCHNER Locking set MGB-L2H-ARA-R-121352; 121352
Locking set MGB-L2H-ARA... (guard locking by solenoid force) with 4 pushbuttons, RC18 Guard locking with guard lock monitoring Can be connected in series with other
-
(Out of stock)
Price on request
EUCHNER Locking module MGB-L1-ARA-AC4A1-S1-L-111103; 111103
Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Can be connected in
-
(Out of stock)
Price on request
Multifunctional Gate Box
The MGB is a safety system with guard locking and guard lock monitoring for the protection of safety doors on machines and installations.
Economical, standard-compliant wiring
The family MGB-AP is particularly suitable for the protection of individual safety doors. If series connection is not necessary, wiring can then be saved. This version has different timing to the AR version.All devices in the family MGB-AR can be wired directly in series in a so-called AR series connection without reducing safety or the PL. As a consequence evaluation units are saved.
AR devices are also available in the EUCHNER series CES and CET.
Seamless integration by means of bus connection
In the PROFINET version, MGB-PN, we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary PROFINET input and output bytes required. Comprehensive diagnostic information in the form of PROFINET messages makes troubleshooting quick and specific. Due to the typical ease with which parameters can be set in PROFINET, even the replacement of the system in case of servicing is a simple matter and can be undertaken in a few minutes.In the MGB Ethernet/IP™ version, we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary CIP Safety input and output bytes required. Whether interlocking, guard locking, escape release or other functions such as buttons for start/stop, emergency stop, selector switch, etc. – the MGB meets all requirements for safety-related applications and can be equipped on a customer-specific basis. Comprehensive diagnostic information in the form of Ethernet/IP™ messages provides a fast and detailed overview of the device status. Due to the ease with which parameters can be set, even replacing the system during servicing is a simple matter and takes no more than a few minutes.