NIETZ NZ2000 series 30/37 kW three phase input ; NZ2400-30G/37P
NZ2000 series Compact Sensorless Vector control VFD NZ2000 VFD , three phase input, output power : G type 30 kW(for constant torque) ; P type 37 kW(for variable...
VAT-exclusive price: 133.154,12 |
VAT-inclusive price: 159.784,94 |
NZ2000 series Compact Sensorless Vector control VFD
NZ2000 VFD , three phase input, output power : G type 30 kW(for constant torque) ; P type 37 kW(for variable torque) output current 60/75 A. IP20 protection
Avilable power range :
Single phase input(220V input voltage) : 0.4-3.7kW
Three phase input (3x380V input voltage) : 0.4-450kW
This is General Purpose variable frequency drive, most widely used in food and beverage industry, pumps or fans, conveyors and machine tools.
Reliable and compact VFD.
Internal brake transistor.
Overload capacity is 150% for 60s.
There are two types of control mode :
Sensorless vector control ( SLVC) and typical adjustable V/f control.
Item specification |
||
Standard functions |
Control mode |
V/F(Voltage/Frequency) control Senseless flux vector control (VC) |
Maximum frequency |
Vector control: 0-300 Hz; V/F control: 0-320Hz |
|
Carrier frequency |
1.0-16.0 kHz; The carrier frequency is automatically adjusted based on the load features. |
|
Input frequency solution |
Digital setting: 0.01 Hz Analog setting: 0.025% of maximum frequency |
|
Startup torque |
G type: 0.5 Hz/150% (VC) P type: 0.5 Hz/100% (VC) |
|
Speed range/stability accuracy |
1:100 (VC) / ± 0.2% (VC) |
|
Torque control accuracy |
± 20% |
|
Overload capacity |
G type: 60s for 150% of the rated current, 3s for 180% of the rated current. |
|
Toque boost |
Auto boost Customized boost 0.1%-30.0% |
|
V/F curve |
Line V/F curve Multi-point V/F curve N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square) |
|
V/F separation |
Two rypes: comlete separation; half separation |
|
Ramp mode |
Straight-line ramp: S-curve ramp Four groups of acceleration/deceleration time with the range of 0.0-6500.0s |
|
Standard functions |
DS braking |
DC braking frequency: 0.00 Hz to maximum frequency Brakin time: 0.0-100.0s; Braking acation current value: 0.0%-100.0% |
JOG control |
JOG frequency range: 0.00-50.00 Hz JOG acceleration/deceleration time: 0.0-6500.0s |
|
Onboard multiple preset speeds |
It impements up to 16 speeds via the simple plc function or combination of rerminal states |
|
Onboard PID |
It realizes process-controlled closed loop control system easily. |
|
Auto voltage regulation (AVR) |
It can keep constant output voltage automatically when the mains voltage changes. |
|
Overvoltage/overcurrent stall control |
The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/ over current tripping during the running process |
|
Torque limit and control |
It can limit the torque automatically and prevent frequent over current tripping during the running process. |
|
Power dip ride through |
The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time |
|
Rapid current limit |
It helps to avoid frequent over current faults of the AC drive. |
|
High performance |
Control of asynchronous motoris implemented through the high-performance current vector control technology. |
|
Timing control |
Time range: 0.0-6500.0 minutes |
|
Communication methods |
RS485 (MODBUS-RTU) |
|
Protection mode |
Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, overvoltage protection, under voltage protection, overheat protection and overload protection. |
|
Input and output |
Input terminal |
6 digital input terminals, one of which supports up to 100 kHz high-speedpulse input. 2 analog input terminals, one of which supports 0-10 V voltage input and the other supports 0-10 V voltage input or 4-20 mA current input. |
Frequency source |
Digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. |
|
Auxiliary frequency source |
There are ten auxiliary frequency sources. It can implement fine running of auxiliary frequency and frequency synthesis. |
|
Running command source |
Operation panel/Control rerminal/Serial communication port. You can perform switchover between these sources in various ways. |
|
Output terminal |
1 digiral output terminal; 1 relay output terminal 1 analog output terminal: that supports 0-20 mA current output or 0-10 V voltage output |
|
keyboard |
LED display |
It displays the parameters. |
Key locking and function selection |
It can lock the keys partially or completely and define the function range of some keys so as to prevent mis-function. |
Similar products:
NIETZ NZ2000 series 1.5kW three phase input ; NZ2400-01R5G
(In stock)
NIETZ NZ2000 series 2.2kW three phase input ; NZ2400-02R2G
(In stock)
NIETZ NZ2000 series 3.7/5.5kW three phase input ; NZ2400-03R7G/05R5P
(Out of stock)
NIETZ NZ2000 series 5.5 kW three phase input ; NZ2400-05R5G
(Out of stock)
NIETZ NZ2000 series 7.5/11 kW three phase input ; NZ2400-07R5G/11P
(In stock)
NIETZ NZ8000 series 30/37 kW three phase VFD ; NZ8400-30G/37P
(In stock)