NIETZ NZ8000 series 22/30 kW three phase VFD ; NZ8400-22G/30P
Variable freqency drive NZ8400-22G/30P , three phase, output power 22kW for G type (constant torque) or 30kW for P type (variable torque) , output current 45.0/60.0A....
VAT-exclusive price: 120.504,13 |
VAT-inclusive price: 144.604,95 |
Variable freqency drive NZ8400-22G/30P , three phase, output power 22kW for G type (constant torque) or 30kW for P type (variable torque) , output current 45.0/60.0A. IP20 protection
High performance variable frequency drive , NZ8000 series from NIETZ. It can drive variety of motors : Synchronous motor, Induction motor, high-spindle motor, AC servo motor. Robust, reliable, made of high quality materials and tested in bad conditions.
Available power range :
Single phase input : 0.75-3.7kW
Three phase input : 0.75-630kW
Features:
High performance variable frequency drive , NZ8000 series from NIETZ. It can drive variety of motors : Synchronous motor, Induction motor, high-spindle motor, AC servo motor. Robust, reliable, made of high quality materials and tested in bad conditions.
Available power range :
Single phase input : 0.75-3.7kW
Three phase input : 0.75-630kW
Features:
- Open loop vector control
- Closed loop vector control
- High speed and torque control accuracy
- Multi-speed and simple PLC setting
- Integrated PID
- Support for multiple option card
- Integrated Modbus RTU, Profibus-DP optional, CANopen optional
- LED display
- Up to 16 preset speeds
- High torque at low speeds
item | NZ8000 |
Control mode |
V/f control: Sensorless flux vector control (SFVC) ; Closed-loop vector control ( CLVC) |
Maximum frequency |
Vector control : 0-320Hz V/f control : 0-3200Hz |
Switching frequency | 1.0-16.0 kHz |
Input frequency resolution | Digital setting : 0.01Hz/ Analog setting: 0.025% of maximum frequency |
Startup torque |
G type : 0.5Hz/150% (SFVC);0Hz/180% (CLVC) P type : 0.5Hz/100% |
Speed range | 1:100 (SFVC) / 1 : 1000 ( CLVC) |
Speed stability accuracy | ±0.5% (SFVC) / ±0.02%(CLVC) |
Torque control accuracy | ±5% (CLVC) |
Overload capacity |
G type : 150% for 60s ; 180% for 3s P type: 120 % for 60s ; 150% for 3s |
Torque boost | Auto boost/ Customized boost 0.1%-30.0% |
V/f curve | Adjustable |
V/f separation |
Half separation Complete separation |
Ramp mode | Straight line ramp; S-curve ramp |
DC braking | Yes |
Jog control |
Jog frequency range : 0-50Hz Jog acc/dec time : 0-6500.0s |
Onboard PID | It realizes process controlled closed loop control system easily |
Auto voltage regulation | It can keep constant output voltage automatically when the mains voltage changes |
Overvoltage/Overcurrent | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/over current |
Torque limit and control | It can limit the torque automatically and prevent frequent over current tripping during the running process. Torque control can be implemented in the CLVC mode |
Support for multiple PG card | Support for differente PG card |
Power dip ride through | The load feedback energy compensates the voltage reduction so that the AC drive can continue to run a short time |
Rapid current limit | It helps to avoid frequent over current failures |
High performance | Control of asynchronous motor and synchronous motor are implemented through the high performance current vector control technology |
Timing control | 0.0-6500.0minutes |
Communication protocol |
Modbus RTu( standard) , Profibus-DP (optional) Canopen(optional) |
Protection mode | Output short circuit detection at power on, input/output phase loss, over current , over voltage, under voltage, overheat, overload |
Input terminals | 8 digital input terminals, one of which supports up to 100kHz high speed pulse input. 2 analog input terminals, one of which only supports 0-10V voltage input and the other supports 4-20mA and 0-10V. |
Frequency source | Digital setting, analog setting, pulse setting, serial communication setting |
Auxiliary frequency source | 10 |
Running command source | Operation panel/Control terminals/Serial communication port |
Output terminal | 1 high speed pulse output terminal (open-collector) that supports 0-100kHz sqare wave signal output. 1 digital output terminal ; 2 relay output terminals ; 2 analog output terminals |
LED display | It displays the parameters |
Key locking and function selection | It can locks the keys partially or completely and define the function range of some keys so as to prevent miss functions |
Optional parts | PG cards |
Similar products:
NIETZ NZ8000 series 5.5/7.5 kW three phase VFD ; NZ8400-5R5G/7R5P
Variable freqency drive NZ8400-5R5G/7R5P , three phase, output power 5.5kW for G type (constant torque) or 7.5kW for P type (variable torque) , output current 13.0/17.0A.
-
(Out of stock)
38.306,20
NIETZ NZ8000 series 7.5/11 kW three phase VFD ; NZ8400-7R5G/11P
Variable freqency drive NZ8400-7R5G/11P , three phase, output power 7.5kW for G type (constant torque) or 11kW for P type (variable torque) , output current 17/25A.
-
(In stock)
47.308,16
NIETZ NZ8000 series 11/15 kW three phase VFD ; NZ8400-11G/15P
Variable freqency drive NZ8400-11G/15P , three phase, output power 11kW for G type (constant torque) or 15kW for P type (variable torque) , output current 25.0/32.0A.
-
(In stock)
62.469,34
NIETZ NZ8000 series 15/18.5 kW three phase VFD ; NZ8400-15G/18.5P
Variable freqency drive NZ8400-15G/18.5P , three phase, output power 15kW for G type (constant torque) or 18.5kW for P type (variable torque) , output current 32.0/37.0A.
-
(In stock)
83.941,41
NIETZ NZ8000 series 18.5/22 kW three phase VFD ; NZ8400-18.5G/22P
Variable freqency drive NZ8400-18.5G/22P , three phase, output power 18.5 kW for G type (constant torque) or 22 kW for P type (variable torque) , output current
-
(In stock)
104.750,42
NIETZ NZ2000 series 22/30 kW three phase input ; NZ2400-22G/30P
NZ2000 series Compact Sensorless Vector control VFD NZ2000 VFD , three phase input, output power : G type 22kW(for constant torque) ; P type 30kW(for variable torque)
-
(In stock)