Graphic display, Modicon M221, unit, 240 x 160 pixels
Range of product | Modicon M221 |
---|---|
Product or component type | Graphic display |
Range compatibility | Modicon M221 |
current consumption | 40 mA at 5 V DC via RJ45 connector |
Power consumption in W | 1 W |
Display type | Backlit colour STN LCD |
Display colour | Monochrome |
Display resolution | 240 x 160 pixels |
number of key |
4 configurable 6 for navigation |
Standards |
EN/IEC 61131-2 EN/IEC 61010-2-201 |
---|---|
product certifications | CULus |
Marking | CE |
mounting location |
Front cabinet diameter: 22 mm hole Bottom of cabinet diameter: 22 mm hole, connection via mounting accessory |
connector type | RJ45 for communication and power supply |
Height | 126 mm |
Width | 80 mm |
Depth | 63 mm |
Net weight | 0.17 kg |
Ambient air temperature for operation | -15…50 °C |
---|---|
Operating altitude | 0...2000 m |
Storage altitude | 0…2000 m |
Environmental characteristic | Corrosive gas free |
relative humidity |
95 %, non-condensing (transport) 95 %, non-condensing (storage) 95 %, non-condensing (operation) |
Ambient air temperature for storage | -40…70 °C |
IP degree of protection |
IP65 front face: IP20 back part: |
pollution degree | 2 conforming to EN/IEC 60664-1 |
vibration resistance |
1.5 mm (f= 3…150 Hz) 2 gn |
shock resistance | 15 gn for 11 ms |
electromagnetic compatibility |
Electrostatic discharge - test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2 Electrostatic discharge - test level: 4 kV (contact discharge) conforming to EN/IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m (80 MHz...1 GHz) conforming to EN/IEC 61000-4-3 Radiated radio-frequency electromagnetic field immunity test - test level: 3 V/m (1.4...2 GHz) conforming to EN/IEC 61000-4-3 Radiated radio-frequency electromagnetic field immunity test - test level: 1 V/m (2...3 GHz) conforming to EN/IEC 61000-4-3 Magnetic field at power frequency - test level: 30 A/m (50/60 Hz) conforming to EN/IEC 61000-4-8 Electrical fast transient/burst immunity test - test level: 1 kV conforming to EN/IEC 61000-4-4 Surge immunity test - test level: 0.5 kV (common mode) conforming to EN/IEC 61000-4-5 Surge immunity test - test level: 0.5 kV (differential mode) conforming to EN/IEC 61000-4-5 Conducted RF disturbances - test level: 10 Vrms (0.15...80 MHz) conforming to EN/IEC 61000-4-6 Disturbing field emission - test level: 10...150 kHz (power lines (DC)) conforming to EN/IEC 55011 Disturbing field emission - test level: 120...69 dBµV/m QP (power lines (DC)) conforming to EN/IEC 55011 Disturbing field emission - test level: 150...1500 kHz (power lines (DC)) conforming to EN/IEC 55011 Disturbing field emission - test level: 1.5...30 kHz (power lines (DC)) conforming to EN/IEC 55011 Disturbing field emission - test level: 30...230 MHz class A (10 m) conforming to EN/IEC 55011 Disturbing field emission - test level: 230 MHz...1 GHZ class A (10 m) conforming to EN/IEC 55011 Disturbing field emission - test level: 79...63 dBμV/m QP (power lines (DC)) conforming to EN/IEC 55011 Disturbing field emission - test level: 63 dBμV/m QP (power lines (DC)) conforming to EN/IEC 55011 Disturbing field emission - test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 Disturbing field emission - test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 6.3 cm |
Package 1 Width | 8.0 cm |
Package 1 Length | 12.6 cm |
Package 1 Weight | 164.0 g |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 12 |
Package 2 Height | 30.0 cm |
Package 2 Width | 30.0 cm |
Package 2 Length | 40.0 cm |
Package 2 Weight | 4.375 kg |
Unit Type of Package 3 | P06 |
Number of Units in Package 3 | 96 |
Package 3 Height | 70.0 cm |
Package 3 Width | 60.0 cm |
Package 3 Length | 80.0 cm |
Package 3 Weight | 15.744 kg |
Range of product | Modicon M221 |
---|---|
Product or component type | Graphic display |
Range compatibility | Modicon M221 |
current consumption | 40 mA at 5 V DC via RJ45 connector |
Power consumption in W | 1 W |
Display type | Backlit colour STN LCD |
Display colour | Monochrome |
Display resolution | 240 x 160 pixels |
number of key |
4 configurable 6 for navigation |
Standards |
EN/IEC 61131-2 EN/IEC 61010-2-201 |
---|---|
product certifications | CULus |
Marking | CE |
mounting location |
Front cabinet diameter: 22 mm hole Bottom of cabinet diameter: 22 mm hole, connection via mounting accessory |
connector type | RJ45 for communication and power supply |
Height | 126 mm |
Width | 80 mm |
Depth | 63 mm |
Net weight | 0.17 kg |
Ambient air temperature for operation | -15…50 °C |
---|---|
Operating altitude | 0...2000 m |
Storage altitude | 0…2000 m |
Environmental characteristic | Corrosive gas free |
relative humidity |
95 %, non-condensing (transport) 95 %, non-condensing (storage) 95 %, non-condensing (operation) |
Ambient air temperature for storage | -40…70 °C |
IP degree of protection |
IP65 front face: IP20 back part: |
pollution degree | 2 conforming to EN/IEC 60664-1 |
vibration resistance |
1.5 mm (f= 3…150 Hz) 2 gn |
shock resistance | 15 gn for 11 ms |
electromagnetic compatibility |
Electrostatic discharge - test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2 Electrostatic discharge - test level: 4 kV (contact discharge) conforming to EN/IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m (80 MHz...1 GHz) conforming to EN/IEC 61000-4-3 Radiated radio-frequency electromagnetic field immunity test - test level: 3 V/m (1.4...2 GHz) conforming to EN/IEC 61000-4-3 Radiated radio-frequency electromagnetic field immunity test - test level: 1 V/m (2...3 GHz) conforming to EN/IEC 61000-4-3 Magnetic field at power frequency - test level: 30 A/m (50/60 Hz) conforming to EN/IEC 61000-4-8 Electrical fast transient/burst immunity test - test level: 1 kV conforming to EN/IEC 61000-4-4 Surge immunity test - test level: 0.5 kV (common mode) conforming to EN/IEC 61000-4-5 Surge immunity test - test level: 0.5 kV (differential mode) conforming to EN/IEC 61000-4-5 Conducted RF disturbances - test level: 10 Vrms (0.15...80 MHz) conforming to EN/IEC 61000-4-6 Disturbing field emission - test level: 10...150 kHz (power lines (DC)) conforming to EN/IEC 55011 Disturbing field emission - test level: 120...69 dBµV/m QP (power lines (DC)) conforming to EN/IEC 55011 Disturbing field emission - test level: 150...1500 kHz (power lines (DC)) conforming to EN/IEC 55011 Disturbing field emission - test level: 1.5...30 kHz (power lines (DC)) conforming to EN/IEC 55011 Disturbing field emission - test level: 30...230 MHz class A (10 m) conforming to EN/IEC 55011 Disturbing field emission - test level: 230 MHz...1 GHZ class A (10 m) conforming to EN/IEC 55011 Disturbing field emission - test level: 79...63 dBμV/m QP (power lines (DC)) conforming to EN/IEC 55011 Disturbing field emission - test level: 63 dBμV/m QP (power lines (DC)) conforming to EN/IEC 55011 Disturbing field emission - test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 Disturbing field emission - test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 6.3 cm |
Package 1 Width | 8.0 cm |
Package 1 Length | 12.6 cm |
Similar products:
Schneider Electric Modbus serijska veza za XBT terminal - d = 2.5 m - 2 RJ45; XBTZ9980
Magelis XBT N, R, RT, Modbus serial link for XBT terminal, 2.5 m, connectors RJ45
-
(In stock)
941,00
Schneider Electric Modbus serijska veza za XBT terminal - d = 2.5 m - 2 RJ45; XBTZ9980
Magelis XBT N, R, RT, Modbus serial link for XBT terminal, 2.5 m, connectors RJ45
-
(In stock)
941,00
Schneider Electric kontroler M221 24 IO relejni Ethernet ; TM221CE24R
controller M221 24 IO relay Ethernet
-
(In stock)
29.384,00