Schneider Electric Kontroler M221 24 IO relejni Ethernet ; TM221CE24R
controller M221 24 IO relay Ethernet...
VAT-exclusive price: 29.384,00 |
VAT-inclusive price: 35.260,80 |
controller M221 24 IO relay Ethernet
range of product |
Modicon M221
|
|
---|---|---|
product or component type |
Logic controller
|
|
[Us] rated supply voltage |
100...240 V AC
|
|
discrete input number |
14, discrete input conforming to IEC 61131-2 Type 1
|
|
analogue input number |
2 at 0...10 V
|
|
discrete output type |
Relay normally open
|
|
discrete output number |
10 relay
|
|
discrete output voltage |
5...125 V DC
5...250 V AC |
|
discrete output current |
2 A
|
discrete I/O number |
24
|
|
---|---|---|
maximum number of I/O expansion module |
7 for transistor output
7 for relay output |
|
supply voltage limits |
85…264 V
|
|
network frequency |
50/60 Hz
|
|
inrush current |
40 A
|
|
maximum power consumption in VA |
58 VA at 100...240 V with max number of I/O expansion module
35 VA at 100...240 V without I/O expansion module |
|
power supply output current |
0.52 A 5 V for expansion bus
0.16 A 24 V for expansion bus |
|
discrete input logic |
Sink or source (positive/negative)
|
|
discrete input voltage |
24 V
|
|
discrete input voltage type |
DC
|
|
analogue input resolution |
10 bits
|
|
LSB value |
10 mV
|
|
conversion time |
1 ms per channel + 1 controller cycle time for analogue input analog input
|
|
permitted overload on inputs |
+/- 30 V DC for 5 min (maximum) for analog input
+/- 13 V DC (permanent) for analog input |
|
voltage state 1 guaranteed |
>= 15 V for input
|
|
voltage state 0 guaranteed |
<= 5 V for input
|
|
discrete input current |
7 mA for discrete input
5 mA for fast input |
|
input impedance |
3.4 kOhm for discrete input
100 kOhm for analog input 4.9 kOhm for fast input |
|
response time |
35 µs turn-off, I2...I5 terminal(s) for input
10 ms turn-on for output 10 ms turn-off for output 5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input 35 µs turn-on, other terminals terminal(s) for input 5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input 100 µs turn-off, other terminals terminal(s) for input |
|
configurable filtering time |
0 ms for input
3 ms for input 12 ms for input |
|
output voltage limits |
125 V DC
277 V AC |
|
maximum current per output common |
4 A at COM 2
7 A at COM 0 7 A at COM 1 |
|
absolute accuracy error |
+/- 1 % of full scale for analog input
|
|
electrical durability |
100000 cycles AC-12, 120 V, 240 VA, resistive
100000 cycles AC-12, 240 V, 480 VA, resistive 300000 cycles AC-12, 120 V, 80 VA, resistive 300000 cycles AC-12, 240 V, 160 VA, resistive 100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive 100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive 300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive 300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive 100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive 100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive 300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive 300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive 100000 cycles DC-12, 24 V, 48 W, resistive 300000 cycles DC-12, 24 V, 16 W, resistive 100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms) 300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms) |
|
switching frequency |
20 switching operations/minute with maximum load
|
|
mechanical durability |
20000000 cycles for relay output
|
|
minimum load |
1 mA at 5 V DC for relay output
|
|
protection type |
Without protection at 5 A
|
|
reset time |
1 s
|
|
memory capacity |
256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM |
|
data backed up |
256 kB built-in flash memory for backup of application and data
|
|
data storage equipment |
2 GB SD card (optional)
|
|
battery type |
BR2032 lithium non-rechargeable, battery life: 4 year(s)
|
|
backup time |
1 year at 25 °C (by interruption of power supply)
|
|
execution time for 1 KInstruction |
0.3 ms for event and periodic task
|
|
execution time per instruction |
0.2 µs Boolean
|
|
exct time for event task |
60 µs response time
|
|
maximum size of object areas |
255 %TM timers
512 %M memory bits 8000 %MW memory words 255 %C counters 512 %KW constant words |
|
realtime clock |
With
|
|
clock drift |
<= 30 s/month at 25 °C
|
|
regulation loop |
Adjustable PID regulator up to 14 simultaneous loops
|
|
counting input number |
4 fast input (HSC mode) at 100 kHz 32 bits
|
|
counter function |
A/B
Single phase Pulse/direction |
|
integrated connection type |
USB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface Ethernet with RJ45 connector |
|
supply |
(serial)serial link supply: 5 V, <200 mA
|
|
transmission rate |
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 480 Mbit/s for USB |
|
communication port protocol |
USB port: USB - SoMachine-Network
Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network Ethernet |
|
port Ethernet |
10BASE-T/100BASE-TX 1 port with 100 m copper cable
|
|
communication service |
Modbus TCP server
Modbus TCP slave device DHCP client Modbus TCP client Ethernet/IP adapter |
|
local signalling |
1 LED (green)PWR:
1 LED (green)RUN: 1 LED (red)module error (ERR): 1 LED (green)SD card access (SD): 1 LED (red)BAT: 1 LED per channel (green)I/O state: 1 LED (green)SL: Ethernet network activity (green)ACT: Ethernet network link (yellow)Link (Link Status): |
|
electrical connection |
removable screw terminal block for inputs
removable screw terminal block for outputs terminal block, 3 terminal(s) for connecting the 24 V DC power supply connector, 4 terminal(s) for analogue inputs Mini B USB 2.0 connector for a programming terminal |
|
maximum cable distance between devices |
Shielded cable: <10 m for fast input
Unshielded cable: <30 m for output Unshielded cable: <30 m for digital input Unshielded cable: <1 m for analog input |
|
insulation |
Between input and internal logic at 500 V AC
Non-insulated between analogue input and internal logic Non-insulated between analogue inputs Between supply and ground at 1500 V AC Between sensor power supply and ground at 500 V AC Between input and ground at 500 V AC Between output and ground at 1500 V AC Between supply and internal logic at 2300 V AC Between sensor power supply and internal logic at 500 V AC Between output and internal logic at 2300 V AC Between Ethernet terminal and internal logic at 500 V AC Between supply and sensor power supply at 2300 V AC |
|
marking |
CE
|
|
sensor power supply |
24 V DC at 250 mA supplied by the controller
|
|
mounting support |
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715 plate or panel with fixing kit |
|
height |
90 mm
|
|
depth |
70 mm
|
|
width |
110 mm
|
|
net weight |
0.395 kg
|
standards |
EN/IEC 61010-2-201
EN/IEC 61131-2 EN/IEC 60664-1 |
|
---|---|---|
product certifications |
LR
CULus IACS E10 CSA ABS DNV-GL EAC RCM |
|
environmental characteristic |
Ordinary and hazardous location
|
|
resistance to electrostatic discharge |
8 kV in air conforming to EN/IEC 61000-4-2
4 kV on contact conforming to EN/IEC 61000-4-2 |
|
resistance to electromagnetic fields |
10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3 1 V/m 2...2.7 GHz conforming to EN/IEC 61000-4-3 |
|
resistance to magnetic fields |
30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
|
|
resistance to fast transients |
2 kV (power lines) conforming to EN/IEC 61000-4-4
2 kV (relay output) conforming to EN/IEC 61000-4-4 1 kV (I/O) conforming to EN/IEC 61000-4-4 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4 1 kV (serial link) conforming to EN/IEC 61000-4-4 |
|
surge withstand |
2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5
2 kV relay output common mode conforming to EN/IEC 61000-4-5 1 kV I/O common mode conforming to EN/IEC 61000-4-5 1 kV shielded cable common mode conforming to EN/IEC 61000-4-5 0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5 1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5 1 kV relay output differential mode conforming to EN/IEC 61000-4-5 0.5 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5 |
|
resistance to conducted disturbances |
10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6
3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL) 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL) |
|
electromagnetic emission |
Conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to EN/IEC 55011
Conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to EN/IEC 55011 Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011 Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011 Radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011 Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011 Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to EN/IEC 55011 |
|
immunity to microbreaks |
10 ms
|
|
ambient air temperature for operation |
-10…55 °C (horizontal installation)
-10…35 °C (vertical installation) |
|
ambient air temperature for storage |
-25…70 °C
|
|
relative humidity |
10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage) |
|
IP degree of protection |
IP20 with protective cover in place
|
|
pollution degree |
<= 2
|
|
operating altitude |
0...2000 m
|
|
storage altitude |
0…3000 m
|
|
vibration resistance |
3.5 mm at 5…8.4 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting 1 gn at 8.4…150 Hz on symmetrical rail 1 gn at 8.4…150 Hz on panel mounting |
|
shock resistance |
98 m/s² for 11 ms
|
Package 1 Weight |
0.666 kg
|
|
---|---|---|
Package 1 Height |
11.200 cm
|
|
Package 1 width |
14.200 cm
|
|
Package 1 Length |
15.400 cm
|
Sustainable offer status |
Green Premium product
|
|
---|---|---|
EU RoHS Directive |
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration |
|
Mercury free |
Yes
|
|
RoHS exemption information | ||
China RoHS Regulation | ||
Environmental Disclosure | ||
Circularity Profile | ||
WEEE |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
|
|
PVC free |
Yes
|
Similar products:
Schneider Electric Modbus serijska veza za XBT terminal - d = 2.5 m - 2 RJ45; XBTZ9980
Magelis XBT N, R, RT, Modbus serial link for XBT terminal, 2.5 m, connectors RJ45
-
(In stock)
941,00
Schneider Electric displej za M221 kontroler - 240 x 160 piksela; TMH2GDB
Graphic display, Modicon M221, unit, 240 x 160 pixels
-
(In stock)
19.876,00