Schneider Electric Prekostrujni relej 4 mA…1A, 2 C/O ; RM22JA21MR
Overcurrent control relay 4mA…1A, 2 C/O...
VAT-exclusive price: 11.240,00 |
VAT-inclusive price: 13.488,00 |
Overcurrent control relay 4mA…1A, 2 C/O
reset time |
1500 ms at maximum voltage
|
|
---|---|---|
maximum switching voltage |
250 V AC
|
|
minimum switching current |
10 mA at 5 V DC
|
|
maximum switching current |
8 A AC
|
|
[Us] rated supply voltage |
24...240 V AC/DC 50/60 Hz +/- 10 %
|
|
supply voltage limits |
20.4…264 V AC/DC
|
|
operating limits |
- 15 % + 10 % Un
|
|
power consumption in VA |
3.5 VA AC
|
|
maximum power consumption in W |
1.5 W DC
|
|
supply voltage frequency |
50...60 Hz +/- 10 %
|
|
resistance across terminals |
2.5 Ohm at E1-M terminals
0.5 Ohm at E2-M terminals 0.1 Ohm at E3-M terminals |
|
output contacts |
2 C/O
|
|
nominal output current |
8 A
|
|
internal input resistance |
0.1 Ohm
2.5 Ohm 0.5 Ohm |
|
setting accuracy of the switching threshold |
+/- 10 % of the full scale
|
|
switching threshold drift |
<= 0.05 % per degree centigrade depending permissible ambient air temperature
<= 1 % within the supply voltage range |
|
setting accuracy of time delay |
10 %
|
|
time delay drift |
<= 0.05 % per degree centigrade depending permissible ambient air temperature
<= 1 % within the supply voltage range |
|
hysteresis |
5…50 % adjustable of threshold setting
|
|
run-up delay at power-up |
0.3 s
|
|
maximum measuring cycle |
100 ms measurement cycle as true rms value
|
|
repeat accuracy |
+/- 0.5 % for input and measurement circuit
+/- 0.2 % for time delay |
|
measurement error |
< 1 % over the whole range with voltage variation
0.05 %/°C with temperature variation |
|
response time |
<= 500 ms
|
|
threshold setting |
10...100 %
|
|
overvoltage category |
III conforming to IEC 60664-1
III conforming to UL 508 |
|
insulation resistance |
> 100 MOhm at 500 V DC conforming to IEC 60255-27
|
|
insulation |
Between supply and measurement
|
|
mounting position |
Any position
|
|
connections - terminals |
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end |
|
tightening torque |
0.6…1 N.m conforming to IEC 60947-1
|
|
housing material |
Self-extinguishing plastic
|
|
status LED |
LED (yellow)relay ON:
LED (green)power ON: |
|
mounting support |
35 mm DIN rail conforming to EN/IEC 60715
|
|
electrical durability |
100000 cycles
|
|
mechanical durability |
10000000 cycles
|
|
utilisation category |
AC-15 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1 AC-1 conforming to IEC 60947-4-1 DC-1 conforming to IEC 60947-4-1 |
|
safety reliability data |
MTTFd = 296.8 years
B10d = 270000 |
|
contacts material |
Cadmium free
|
|
width |
22.5 mm
|
|
net weight |
0.11 kg
|
immunity to microbreaks |
50 ms
|
|
---|---|---|
electromagnetic compatibility |
Immunity for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-1
Immunity for industrial environments conforming to EN/IEC 61000-6-2 Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 Emission standard for industrial environments conforming to EN/IEC 61000-6-4 Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4 Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5 Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5 Conducted and radiated emissions class B group 1 conforming to CISPR 11 Conducted and radiated emissions class B conforming to CISPR 22 |
|
standards |
EN/IEC 60255-1
|
|
product certifications |
EAC
CSA China RoHS CE RCM CCC UL GL |
|
ambient air temperature for storage |
-40…70 °C
|
|
ambient air temperature for operation |
-20…50 °C at 60 Hz
-20…60 °C at 50 Hz AC/DC |
|
relative humidity |
93…97 % at 25…55 °C conforming to IEC 60068-2-30
|
|
vibration resistance |
0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6 0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6 0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6 |
|
shock resistance |
15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27
5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27 |
|
IP degree of protection |
IP20 (terminals) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529 |
|
pollution degree |
3 conforming to IEC 60664-1
3 conforming to UL 508 |
|
dielectric test voltage |
2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27
|
Package 1 Weight |
0.110 kg
|
|
---|---|---|
Package 1 Height |
0.260 dm
|
|
Package 1 width |
0.820 dm
|
|
Package 1 Length |
0.950 dm
|
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Sustainable offer status |
Green Premium product
|
|
---|---|---|
EU RoHS Directive |
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration |
|
Mercury free |
Yes
|
|
RoHS exemption information | ||
China RoHS Regulation | ||
Environmental Disclosure | ||
Circularity Profile | ||
WEEE |
range of product |
Zelio Control
|
|
---|---|---|
product or component type |
Modular measurement and control relays
|
|
relay type |
Current control relay
|
|
relay name |
RM22JA
|
|
relay monitored parameters |
Overcurrent detection
|
|
time delay type |
Without
|
|
switching capacity in VA |
2000 VA
|
|
measurement range |
4...40 mA E1-M terminals
20...200 mA E2-M terminals 100...1000 mA E3-M terminals 4 mA...1 A current AC/DC 50/60 Hz |
Similar products:
Schneider Electric relej za kontrolu napona RM17-U - opseg 183..528 V AC ; RM17UB310
Modular 3-phase voltage control relay, 5 A, 1 CO, 208...480 V AC
-
(Out of stock)
5.453,00
Schneider Electric Relej za kontrolu struje RM17-J - opseg: 2..20 A ; RM17JC00MW
Modular current control relay, 8 A, 1 CO, overcurrent function, 250 V AC/DC
-
(Out of stock)
8.912,00
Schneider Electric relej za kontrolu napona RM17-U - opseg 65..260 V AC ; RM17UAS15
voltage control relay RM17-U - range 65..260 V AC
-
(Out of stock)
10.871,00
Schneider Electric Relej za kontrolu jačine struje RM35-J - opseg 0.15..1.5 A ; RM35JA32MW
Modular 1-phase current control relay, 5 A, 2 CO, 0.15…15 A,, 24…240 V AC/DC
-
(Out of stock)
14.169,00
Schneider Electric Strujni kontrolni relej 0.15A…15A, 2 C/O ; RM35JA32MR
Current control relay 0.15A…15A, 2 C/O
-
(Out of stock)
15.746,00
Schneider Electric Strujni kontrolni relej 0.15A…15A, 2 C/O ; RM35JA32MT
Current control relay 0.15A…15A, 2 C/O
-
(Out of stock)
16.239,00