Schneider Electric Star delta starter, TeSys Deca, 3 x 3P (3NO), 115A, 230V AC coil; LC3D115P7
Star delta starter, TeSys Deca, 3 x 3P (3NO), 115A, 230V AC coil...
Price on request
Star delta starter, TeSys Deca, 3 x 3P (3NO), 115A, 230V AC coil
Range | TeSys |
---|---|
Product name | TeSys Deca |
Product or component type | Star delta starter |
Device short name | LC3D |
Contactor application | Motor control |
Utilisation category | AC-3 |
Device presentation | Pre-wired |
Poles description | 3 x 3P |
power pole contact composition | 3 x 3 NO |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 25...400 Hz |
[Ie] rated operational current | 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
Motor power kW |
110 kW at 380/400 V AC 50/60 Hz 110 kW at 415 V AC 50/60 Hz 110 kW at 440 V AC 50/60 Hz 63 kW at 220/230 V AC 50/60 Hz |
Control circuit type | AC at 50/60 Hz |
[Uc] control circuit voltage | 230 V AC 50/60 Hz |
Auxiliary contact composition |
1 NC for KM2 line contactor 1 NO for KM3 delta contactor |
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 |
Overvoltage category | III |
[Ui] rated insulation voltage |
Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 1000 V conforming to IEC 60947-1 |
Electrical durability | 0.95 Mcycles 115 A AC-3 at Ue <= 440 V |
Mounting support | Plate |
Standards |
UL 508 EN 60947-5-1 IEC 60947-5-1 IEC 60947-4-1 EN 60947-4-1 CSA C22.2 No 14 |
Product certifications |
GOST RINA BV DNV CSA UL GL LROS (Lloyds register of shipping) CCC |
Connections - terminals |
Power circuit: connector 1 10…120 mm² - cable stiffness: flexible without cable end Power circuit: connector 2 10…50 mm² - cable stiffness: flexible without cable end Power circuit: connector 1 10…120 mm² - cable stiffness: flexible with cable end Power circuit: connector 2 10…50 mm² - cable stiffness: flexible with cable end Power circuit: connector 1 10…120 mm² - cable stiffness: solid without cable end Power circuit: connector 2 10…50 mm² - cable stiffness: solid without cable end Control circuit: connector 1 1…2.5 mm² - cable stiffness: flexible without cable end Control circuit: connector 2 1…2.5 mm² - cable stiffness: flexible without cable end Control circuit: connector 1 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: connector 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: connector 1 1…2.5 mm² - cable stiffness: solid without cable end Control circuit: connector 2 1…2.5 mm² - cable stiffness: solid without cable end |
---|---|
Tightening torque |
Power circuit: 12 N.m - on connector - with screwdriver flat Ø 6...8 mm Control circuit: 1.2 N.m - on connector - with screwdriver flat Ø 6 mm Control circuit: 1.2 N.m - on connector - with screwdriver Philips No 2 |
Mechanical durability | 8 Mcycles |
Maximum operating rate | 30 cyc/h 60 °C |
Starting time | 30 s |
Coil technology | Without built-in suppressor module |
Control circuit voltage limits |
Drop-out: 0.3...0.5 Uc at 50/60 Hz (at <55 °C) Operational: 0.8...1.15 Uc at 50/60 Hz (at <55 °C) |
Inrush power in VA |
280…350 VA 60 Hz cos phi 0.8 (at 20 °C) 280…350 VA 50 Hz cos phi 0.8 (at 20 °C) |
Hold-in power consumption in VA |
2…18 VA 60 Hz cos phi 0.3 (at 20 °C) 2…18 VA 50 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation | 3…8 W at 50/60 Hz |
Auxiliary contacts type |
Mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NC Mirror contact conforming to IEC 60947-4-1 3 x 1 NC |
Signalling circuit frequency | 25...400 Hz |
Minimum switching current | 5 mA for signalling circuit |
minimum switching voltage | 17 V for signalling circuit |
Non-overlap time |
1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
Width | 450 mm |
Height | 555 mm |
Depth | 205 mm |
Net weight | 11.8 kg |
Insulation resistance | > 10 MOhm for signalling circuit |
---|---|
IP degree of protection | IP20 front face conforming to IEC 60529 |
Protective treatment | TH conforming to IEC 60068-2-30 |
Pollution degree | 3 |
Ambient air temperature for storage | -60…80 °C |
Ambient air temperature for operation |
-40…60 °C 60…70 °C with derating |
Operating altitude | 3000 m |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Flame retardance | V1 conforming to UL 94 |
Mechanical robustness |
Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 6 Gn for 11 ms |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 35.0 cm |
Package 1 Width | 67.0 cm |
Package 1 Length | 77.0 cm |
Package 1 Weight | 11.8 kg |
Warranty | 18 months |
---|
Similar products:
Schneider Electric TeSys D kontaktor - 3P(3 NO) - AC-3 - <= 440 V 115 A - 230 V AC 50/60 Hz kalem ; LC1D115P7
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 115 A - 230 V AC 50/60 Hz coil
-
(Out of stock)
43.673,00
Schneider Electric Star delta starter, TeSys Deca, 3 x 3P (3NO), 12A, 230V AC coil; LC3D120AP7
Star delta starter, TeSys Deca, 3 x 3P (3NO), 12A, 230V AC coil
-
(Out of stock)
Price on request
Schneider Electric TeSys D - pokretač zvezda-trougao - 3 x 3P (3 NO) - 18 A - 230 V AC kalem; LC3D180AP7
TeSys Deca, star delta starter, 3 x 3P (3NO), 18A, 230V AC coil; LC3D180AP7
-
(Out of stock)
73.907,00
Schneider Electric Star delta starter, TeSys Deca, 3 x 3P (3NO), 80A, 230V AC coil; LC3D80P7
Star delta starter, TeSys Deca, 3 x 3P (3NO), 80A, 230V AC coil; LC3D80P7
-
(Out of stock)
184.934,00
Schneider Electric Star delta starter, TeSys Deca, 3 x 3P (3NO), 115A, 230V AC coil; LC3D115P7A64
Star delta starter, TeSys Deca, 3 x 3P (3NO), 115A, 230V AC coil
-
(Out of stock)
Price on request
Schneider Electric TeSys Deca, star delta starter, 3 x 3P(3NO), 150A, 230V AC coil; LC3D150P7A64
TeSys Deca, star delta starter, 3 x 3P(3NO), 150A, 230V AC coil
-
(Out of stock)
Price on request