Schneider Electric TeSys F kontaktor - 4P(4 NO) - AC-1 - <= 440 V 700 A - bez kalema;LC1F5004

Schneider Electric TeSys F kontaktor - 4P(4 NO) - AC-1 - <= 440 V 700 A - bez kalema;LC1F5004

TeSys F contactor - 4P(4 NO)-AC-1 <= 440V 700A with coil LX1/ LX9 - 48…1000V AC 40/400Hz, LX4 - 48...440V DC...

Brand: Schneider Electric
Product Code: LC1F5004
Availability: Check availability
VAT-exclusive price: 339.575,00
VAT-inclusive price: 407.490,00

TeSys F contactor - 4P(4 NO)-AC-1 <= 440V 700A with coil LX1/ LX9 - 48…1000V AC 40/400Hz, LX4 - 48...440V DC

Main
range
TeSys
 
product name
TeSys F
 
product or component type
Contactor
 
device short name
LC1F
 
contactor application
Resistive load
 
utilisation category
AC-1
 
poles description
4P
 
power pole contact composition
4 NO
 
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz
<= 460 V DC
 
[Ie] rated operational current
700 A (at <40 °C) at <= 440 V AC AC-1
 
Complementary
[Uc] control circuit voltage
48...1000 V AC 40...400 Hz with LX1/LX9 coil
48...440 V DC with LX4 coil
 
[Uimp] rated impulse withstand voltage
8 kV
 
overvoltage category
III
 
[Ith] conventional free air thermal current
700 A (at 40 °C)
 
Irms rated making capacity
5000 A AC conforming to IEC 60947-4-1
 
rated breaking capacity
4000 A conforming to IEC 60947-4-1
 
[Icw] rated short-time withstand current
4200 A 40 °C - 10 s
3200 A 40 °C - 30 s
2400 A 40 °C - 1 min
1500 A 40 °C - 3 min
1200 A 40 °C - 10 min
 
associated fuse rating
500 A aM at <= 440 V
800 A gG at <= 440 V
 
average impedance
0.18 mOhm - Ith 700 A 50 Hz
 
[Ui] rated insulation voltage
1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
 
power dissipation per pole
88 W AC-1
 
control circuit voltage limits
Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil
Drop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1/LX9 coil
Operational: 0.85...1.1 Uc DC with LX4 coil
Drop-out: 0.2...0.35 Uc DC with LX4 coil
 
heat dissipation
18 W
 
operating time
40...75 ms closing for with LX1/LX9 coil
100...170 ms opening for with LX1/LX9 coil
50...60 ms closing for with LX4 coil
45...60 ms opening for with LX4 coil
 
mounting support
Plate
 
standards
JIS C8201-4-1
EN 60947-1
IEC 60947-1
EN 60947-4-1
IEC 60947-4-1
 
product certifications
CSA
LROS (Lloyds register of shipping)
DNV
BV
ABS
CB
RMRoS
RINA
UL
 
connections - terminals
Power circuit: lugs-ring terminals 2 cable(s) 240 mm²
Power circuit: bar 2 cable(s) - busbar cross section: 40 x 5 mm
Power circuit: bolted connection
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
 
tightening torque
Power circuit: 35 N.m
Control circuit: 1.2 N.m
 
mechanical durability
10 Mcycles
 
inrush power in VA
1050…1150 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
990…1220 VA (at 20 °C)with LX4 coil
 
hold-in power consumption in VA
16…20 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
4.54…8 VA (at 20 °C)with LX4 coil
 
maximum operating rate
2400 cyc/h 55 °C
 
compatibility code
LC1F
 
Environment
IP degree of protection
IP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
 
protective treatment
TH
 
ambient air temperature for operation
-5…55 °C
 
ambient air temperature for storage
-60…80 °C
 
permissible ambient air temperature around the device
-40…70 °C
 
mechanical robustness
Vibrations contactor open: 2 Gn, 5...300 Hz
Vibrations contactor closed: 4 Gn, 5...300 Hz
Shocks contactor open: 9 Gn for 1/2 sine wave (11 ms)
Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
 
height
238 mm
 
width
288 mm
 
  • TeSys F LC1F5004

    TeSys F LC1F5004



Similar products:


Schneider Electric TeSys F kontaktor - 4P(4 NO) - AC-1 - <= 440 V 200 A - bez kalema; LC1F1154

TeSys F contactor - 4P(4 NO)-AC-1 <= 440V 200A with coil LX9 - 24...575V AC 40/400Hz, LX4 - 24...460V DC, LXE - 100...250V AC 50/60Hz or 100…380V DC
-
Need to order

(Out of stock)

 
 
86.593,00

Schneider Electric TeSys F kontaktor - 4P(4 NO) - AC-1 - <= 440 V 250 A - bez kalema; LC1F1504

TeSys F contactor - 4P(4 NO)-AC-1 <= 440V 250A with coil LX9 - 24...575V AC 40/400Hz, LX4 - 24...460V DC, LXE - 100...250V AC 50/60Hz or 100…380V DC
-
Need to order

(Out of stock)

 
 
98.476,00

Schneider Electric TeSys F kontaktor - 4P(4 NO) - AC-1 - <= 440 V 315 A - bez kalema; LC1F2254

TeSys F contactor - 4P(4 NO)-AC-1 <= 440V 315A with coil LX9 - 24...575V AC 40/400Hz, LX4 - 24...460V DC, LXE - 100...250V AC 50/60Hz or 100…380V DC
-
Need to order

(Out of stock)

 
 
152.812,00

Schneider Electric TeSys F kontaktor - 4P(4 NO) - AC-1 - <= 440 V 350 A - bez kalema;LC1F2654

TeSys F contactor-4P(4 NO)-AC-1 <= 440V 350A with coil LX1/LX9 -24…1000V AC 40/400Hz, LX4 -24...460V DC, LXE -100...250V AC 50/60Hz or 100…380V
-
Need to order

(Out of stock)

 
 
181.107,00

Schneider Electric TeSys F kontaktor - 4P(4 NO) - AC-1 - <= 440 V 500 A - bez kalema;LC1F4004

TeSys F contactor-4P(4 NO)-AC-1 <= 440V 500A with coil LX1/LX9 -48…1000V AC 40/400Hz, LX4 -48...440V DC, LXE -100...250V AC 50/60Hz or 100…380V
-
Need to order

(Out of stock)

 
 
226.386,00

Schneider Electric TeSys F kontaktor - 4P(4 NO) - AC-1 - <= 440 V 1000 A - bez kalema;LC1F6304

TeSys F contactor - 4P(4 NO)-AC-1 <= 440V 1000A with coil LX1/ LX9 - 48…1000V AC 40/400Hz, LX4 - 48...440V DC
-
Need to order

(Out of stock)

 
 
486.725,00

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products