Schneider Electric TeSys GV2 - motorni prekidač - termomagnetna zaštita - 6…10 A; GV2P14

Schneider Electric TeSys GV2 - motorni prekidač - termomagnetna zaštita - 6…10 A; GV2P14

Motor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, screw clamp terminals...

Brand: Schneider Electric
Product Code: GV2P14
Availability: Check availability
VAT-exclusive price: 9.322,00
VAT-inclusive price: 11.186,40

Motor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, screw clamp terminals

Main
range
TeSys
 
product name
TeSys GV2
 
device short name
GV2P
 
device application
Motor
 
trip unit technology
Thermal-magnetic
 
Complementary
poles description
3P
 
network type
AC
 
utilisation category
AC-3 conforming to IEC 60947-4-1
Category A conforming to IEC 60947-2
 
network frequency
50/60 Hz conforming to IEC 60947-4-1
 
fixing mode
35 mm symmetrical DIN rail: clipped
Panel: screwed (with 2 x M4 screws)
 
operating position
Any position
 
motor power kW
3 kW at 400/415 V AC 50/60 Hz
5.5 kW at 690 V AC 50/60 Hz
5 kW at 500 V AC 50/60 Hz
 
breaking capacity
100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
 
[Ics] rated service short-circuit breaking capacity
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
 
control type
Rotary knob
 
[In] rated current
10 A
 
thermal protection adjustment range
6…10 A
 
magnetic tripping current
138 A
 
[Ue] rated operational voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
 
[Ui] rated insulation voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
 
[Ith] conventional free air thermal current
10 A conforming to IEC 60947-4-1
 
[Uimp] rated impulse withstand voltage
6 kV IEC 60947-2
 
power dissipation per pole
2.5 W
 
mechanical durability
100000 cycles
 
electrical durability
100000 cycles for AC-3 at 440 V
 
maximum operating rate
25 cyc/h
 
rated duty
Continuous conforming to IEC 60947-4-1
 
connections - terminals
Screw clamp terminals 2 cable(s) 1…6 mm² solid
Screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable end
Screw clamp terminals 2 cable(s) 1…4 mm² flexible with cable end
 
tightening torque
1.7 N.m on screw clamp terminals
 
suitability for isolation
Yes conforming to IEC 60947-1
 
phase failure sensitivity
Yes conforming to IEC 60947-4-1
 
height
89 mm
 
width
45 mm
 
depth
97 mm
 
Environment
standards
EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
 
product certifications
IECEE CB Scheme
UL
CSA
CCC
EAC
ATEX
BV
LROS (Lloyds register of shipping)
DNV-GL
RINA
 
protective treatment
TH
 
IP degree of protection
IP20 conforming to IEC 60529
 
IK degree of protection
IK04
 
ambient air temperature for operation
-20…60 °C
 
ambient air temperature for storage
-40…80 °C
 
fire resistance
960 °C conforming to IEC 60695-2-1
 
operating altitude
2000 m
 
Packing Units
Unit Type of Package 1
PCE
 
Number of Units in Package 1
1
 
Package 1 Weight
326 g
 
Package 1 Height
5 cm
 
Package 1 width
9.4 cm
 
Package 1 Length
10 cm
 
Unit Type of Package 2
S02
 
Number of Units in Package 2
20
 
Package 2 Weight
6.852 kg
 
Package 2 Height
15 cm
 
Package 2 width
30 cm
 
Package 2 Length
40 cm
 
Unit Type of Package 3
P06
 
Number of Units in Package 3
320
 
Package 3 Weight
124.58 kg
 
Package 3 Height
80 cm
 
Package 3 width
80 cm
 
Package 3 Length
60 cm
 
Offer Sustainability
Sustainable offer status
Green Premium product
 
EU RoHS Directive  
Mercury free
Yes
 
RoHS exemption information  
China RoHS Regulation
China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information
 
Environmental Disclosure  
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
 
Contractual warranty
Warranty
18 months
  • TeSys GV2 GV2P14

    TeSys GV2 GV2P14



Similar products:


Schneider Electric TeSys GV2-prekidač-termomagnetna zaštita - 6...10 A - vijčani priključak; GV2ME14

Motor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, screw clamp terminals
-
Need to order

(Out of stock)

 
 
7.457,00

Schneider Electric TeSys GV2 - motorni prekidač - termomagnetna zaštita - 0.1…0.16 A; GV2P01

Motor circuit breaker, TeSys GV2, 3P, 0.1-0.16 A, thermal magnetic, screw clamp terminals
-
Need to order

(Out of stock)

 
 
7.562,00

Schneider Electric TeSys GV2 - motorni prekidač - termomagnetna zaštita - 17…23 A; GV2P21

Motor circuit breaker, TeSys GV2, 3P, 17-23 A, thermal magnetic, screw clamp terminals
-
Need to order

(Out of stock)

 
 
11.086,00

Schneider Electric TeSys GV2-prekidač-termomagnetna zaštita - 6.3…10 A - vijčani priključak; GV2RT14

Motor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, screw clamp terminals
-
Need to order

(Out of stock)

 
 
12.509,00

Schneider Electric TeSys GV2 - motorni prekidač - termomagnetna zaštita - 20…25 A; GV2P22

Motor circuit breaker, TeSys GV2, 3P, 20-25 A, thermal magnetic, screw clamp terminals
-
Need to order

(Out of stock)

 
 
12.672,00

Schneider Electric TeSys GV2 - motorni prekidač - termomagnetna zaštita - 24…32 A; GV2P32

Motor circuit breaker, TeSys GV2, 3P, 24-32 A, thermal magnetic, screw clamp terminals
-
Need to order

(Out of stock)

 
 
18.038,00

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products