Schneider Electric Zaštitna jedinica MicroLogic 5.2 E za ComPacT NSX 100/160/250 prekidače, elektronska, struja 40A, 4P 4d;C1045E040

Schneider Electric Zaštitna jedinica MicroLogic 5.2 E za ComPacT NSX 100/160/250 prekidače, elektronska, struja 40A, 4P 4d;C1045E040

Trip unit MicroLogic 5.2E, ComPacT NSX100/160/250, 4 poles, electronic basic protections, energy meter, 40A rating...

Brand: Schneider Electric
Product Code: C1045E040
Availability: Check availability
VAT-exclusive price: 48.152,00
VAT-inclusive price: 57.782,40

Trip unit MicroLogic 5.2E, ComPacT NSX100/160/250, 4 poles, electronic basic protections, energy meter, 40A rating


Main
range ComPacT new generation
range of product ComPacT NSX100...250 new generation
product or component type Trip unit
trip unit name Micrologic 5.2 E
trip unit technology Electronic
range compatibility ComPacT new generation NSX100
ComPacT new generation NSX160
ComPacT new generation NSX250
device application Distribution
poles description 4P
protected poles description 3D + N/2
4D
3D + OSN
3D
neutral position Left
trip unit protection functions LSI
protection type L : for overload protection (long time)
S : for short time short-circuit protection
I : for instantaneous short-circuit protection
Trip unit rating 40 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
network type AC
network frequency 50/60 Hz
Circuit breaker mounting mode Fixed
Complementary
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 18...40 A
Long-time protection delay adjustment type tr Adjustable
[tr] long-time protection delay adjustment range 15…400 s at 1.5 x Ir
0.35…11 s at 7.2 x Ir
0.5…16 s at 6 x Ir
Neutral protection settings 0.5 x Ir (3D + N/2)
1 x Ir (4D)
1.6 x Ir (3D + OSN)
No protection (3D)
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Adjustable
[tsd] Short-time protection delay adjustment range 0…0.4 s I²t=off
0.1…0.4 s I²t=on
Instantaneous protection pick-up adjustment type Ii Adjustable
[Ii] instantaneous protection pick-up adjustment range 1.5...15 x In
earth-leakage protection Without
zone selective interlocking ZSI With
local signalling Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
display type LCD display
type of measurement Energy meter
communication of data Energy metering
Protection and alarm settings
Time-stamped histories and event tables
Instantaneous and demand values
Maintenance indicators
Demand current and power
Power quality
Maximeters/minimeters
electrical data recording Maintenance indicators
Environment
standards EN/IEC 60947-2
electrical shock protection class Class II
pollution degree 3 conforming to IEC 60947-1
IP degree of protection IP40 conforming to IEC 60529
ambient air temperature for operation -25…70 °C
ambient air temperature for storage -40…85 °C
 
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 671.0 g
Package 1 Height 9.8 cm
Package 1 width 11.0 cm
Package 1 Length 15.0 cm
Unit Type of Package 2 S03
Number of Units in Package 2 11
Package 2 Weight 7.827 kg
Package 2 Height 30.0 cm
Package 2 width 30.0 cm
Package 2 Length 40.0 cm
Package 3 Height 150 cm

Main
range ComPacT new generation
range of product ComPacT NSX100...250 new generation
product or component type Trip unit
trip unit name Micrologic 5.2 E
trip unit technology Electronic
range compatibility ComPacT new generation NSX100
ComPacT new generation NSX160
ComPacT new generation NSX250
device application Distribution
poles description 4P
protected poles description 3D + N/2
4D
3D + OSN
3D
neutral position Left
trip unit protection functions LSI
protection type L : for overload protection (long time)
S : for short time short-circuit protection
I : for instantaneous short-circuit protection
Trip unit rating 40 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
network type AC
network frequency 50/60 Hz
Circuit breaker mounting mode Fixed

Similar products:


Schneider Electric prekidač ComPacT NSX100F AC/DC, 18 kA na 240 VAC, TMD zaštitna jedinica 20 A, 1P 1d;C10F1TM020

Circuit breaker, ComPacT NSX100F AC/DC, 18kA/240VAC, 1 pole, TMD trip unit 20A
-
Need to order

(Out of stock)

 
 
12.387,00

Schneider Electric prekidač ComPacT NSX100F AC/DC, 18 kA na 415 VAC, TMD zaštitna jedinica 20 A, 2P 2d;C10F2TM020

Circuit breaker, ComPacT NSX100F AC/DC, 18kA/415VAC, 2 poles, TMD trip unit 20A
-
Need to order

(Out of stock)

 
 
16.693,00

Schneider Electric prekidač ComPacT NSX100M AC/DC, 25 kA na 415 VAC, TMD zaštitna jedinica 20 A, 2P 2d;C10M2TM020

Circuit breaker, ComPacT NSX100M AC/DC, 25kA/415VAC, 2 poles, TMD trip unit 20A
-
Need to order

(Out of stock)

 
 
19.196,00

Schneider Electric prekidač ComPacT NSX160F AC/DC, 18 kA na 240 VAC, TMD zaštitna jedinica 160 A, 1P 1d;C16F1TM160

Circuit breaker, ComPacT NSX160F AC/DC, 18kA/240VAC, 1 pole, TMD trip unit 160A
-
Need to order

(Out of stock)

 
 
24.368,00

Schneider Electric prekidač ComPacT NSX500F DC, 36 kA na 750 VDC, TM-DC zaštitna jedinica, 500 A struja, 3P;C63F3TM500D

Circuit breaker, ComPacT NSX630F DC, 36kA/750VDC, 3 poles, TM-DC trip unit 500A
-
Need to order

(Out of stock)

 
 
142.118,00

Schneider Electric prekidač ComPacT NSX250F DC, 36 kA na 750 VDC, TM-DC zaštitna jedinica, 250 A struja, 4P;C40F4TM250D

Circuit breaker, ComPacT NSX400F DC, 36kA/750VDC, 4 poles, TM-DC trip unit 250A
-
Need to order

(Out of stock)

 
 
153.636,00

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products
Complementary
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 18...40 A
Long-time protection delay adjustment type tr Adjustable
[tr] long-time protection delay adjustment range 15…400 s at 1.5 x Ir
0.35…11 s at 7.2 x Ir
0.5…16 s at 6 x Ir
Neutral protection settings 0.5 x Ir (3D + N/2)
1 x Ir (4D)
1.6 x Ir (3D + OSN)
No protection (3D)
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Adjustable
[tsd] Short-time protection delay adjustment range 0…0.4 s I²t=off
0.1…0.4 s I²t=on
Instantaneous protection pick-up adjustment type Ii Adjustable
[Ii] instantaneous protection pick-up adjustment range 1.5...15 x In
earth-leakage protection Without
zone selective interlocking ZSI With