Schneider Electric Zaštitna jedinica MicroLogic 7.3 E za ComPacT NSX 630 prekidače, elektronska, struja 570A, 3P 3d;C6337E570

Schneider Electric Zaštitna jedinica MicroLogic 7.3 E za ComPacT NSX 630 prekidače, elektronska, struja 570A, 3P 3d;C6337E570

Trip unit MicroLogic Vigi 7.3E, ComPacT NSX630, 3 poles, basic and earth leakage protections, energy meter, 570A rating...

Brand: Schneider Electric
Product Code: C6337E570
Availability: Check availability
VAT-exclusive price: 218.436,00
VAT-inclusive price: 262.123,20

Trip unit MicroLogic Vigi 7.3E, ComPacT NSX630, 3 poles, basic and earth leakage protections, energy meter, 570A rating


Main
range ComPacT new generation
range of product ComPacT NSX400...630 new generation
product or component type Trip unit
trip unit name Micrologic 7.3 E
trip unit technology Electronic
range compatibility ComPacT new generation NSX630
device application Distribution
poles description 3P
protected poles description 3D
trip unit protection functions LSIR
protection type L : for overload protection (long time)
S : for short time short-circuit protection
I : for instantaneous short-circuit protection
R : for earth-leakage protection
Trip unit rating 570 A at 40 °C
[Ue] rated operational voltage 440 V AC 50/60 Hz
network type AC
network frequency 50/60 Hz
Circuit breaker mounting mode Fixed
Complementary
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 250...570 A
Long-time protection delay adjustment type tr Adjustable
[tr] long-time protection delay adjustment range 15…400 s at 1.5 x Ir
0.35…11 s at 7.2 x Ir
0.5…16 s at 6 x Ir
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Adjustable
[tsd] Short-time protection delay adjustment range 0…0.4 s
Instantaneous protection pick-up adjustment type Ii Adjustable
[Ii] instantaneous protection pick-up adjustment range 1.5...11 x In
earth-leakage protection Integrated
earth-leakage protection class Class A
Earth-leakage protection sensitity adjustment type IΔn Adjustable
[IΔn] earth-leakage protection sensitivity adjustment range 0.3 A
0.5 A
1 A
3 A
5 A
10 A
Earth-leakage protection specific mode OFF using the IΔn rotary switch
Earth-leakage protection time delay adjustement type Δt Adjustable
[Δt] Earth-leakage protection time delay adjustment range 0 ms
60 ms
150 ms
500 ms
1 s
zone selective interlocking ZSI Without
local signalling Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
display type LCD display
type of measurement Energy meter
communication of data Power quality
Earth leakage current
Protection and alarm settings
Maintenance indicators
Maximeters/minimeters
Energy metering
Demand current and power
Instantaneous and demand values
Test reports
Time-stamped histories and event tables
Environment
standards EN/IEC 60947-2
electrical shock protection class Class II
pollution degree 3 conforming to IEC 60947-1
IP degree of protection IP40 conforming to IEC 60529
ambient air temperature for operation -25…70 °C
ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 1.884 kg
Package 1 Height 11.3 cm
Package 1 width 9.5 cm
Package 1 Length 14.0 cm
Unit Type of Package 2 P06
Number of Units in Package 2 16
Package 2 Weight 49.18 kg
Package 2 Height 105.0 cm
Package 2 width 60.0 cm
Package 2 Length 80.0 cm
Unit Type of Package 3 S03
Number of Units in Package 3 2
Package 3 Weight 4.27 kg
Package 3 Height 30.0 cm
Package 3 width 30.0 cm
Package 3 Length 40.0 
Main
range ComPacT new generation
range of product ComPacT NSX400...630 new generation
product or component type Trip unit
trip unit name Micrologic 7.3 E
trip unit technology Electronic
range compatibility ComPacT new generation NSX630
device application Distribution
poles description 3P
protected poles description 3D
trip unit protection functions LSIR
protection type L : for overload protection (long time)
S : for short time short-circuit protection
I : for instantaneous short-circuit protection
R : for earth-leakage protection
Trip unit rating 570 A at 40 °C
[Ue] rated operational voltage 440 V AC 50/60 Hz
network type AC
network frequency 50/60 Hz
Circuit breaker mounting mode Fixed

Similar products:


Schneider Electric prekidač ComPacT NSX100F AC/DC, 18 kA na 240 VAC, TMD zaštitna jedinica 80 A, 1P 1d;C10F1TM080

Circuit breaker, ComPacT NSX100F AC/DC, 18kA/240VAC, 1 pole, TMD trip unit 80A
-
Need to order

(Out of stock)

 
 
13.159,00

Schneider Electric prekidač osnovni model, ComPacT NSX100F DC, 36 kA na 750 VDC, 100 A, bez zaštitne jedinice, 3P;C10F3D

Circuit breaker basic frame, ComPacT NSX100F DC, 36kA/750VDC, 3 poles, 100A frame rating, without trip unit
-
Need to order

(Out of stock)

 
 
13.667,00

Schneider Electric prekidač ComPacT NSX100F AC/DC, 18 kA na 415 VAC, TMD zaštitna jedinica 40 A, 2P 2d;C10F2TM040

Circuit breaker, ComPacT NSX100F AC/DC, 18kA/415VAC, 2 poles, TMD trip unit 40A
-
Need to order

(Out of stock)

 
 
16.693,00

Schneider Electric prekidač ComPacT NSX100M AC/DC, 25 kA na 415 VAC, TMD zaštitna jedinica 40 A, 2P 2d;C10M2TM040

Circuit breaker, ComPacT NSX100M AC/DC, 25kA/415VAC, 2 poles, TMD trip unit 40A
-
Need to order

(Out of stock)

 
 
19.196,00

Schneider Electric prekidač ComPacT NSX320F DC, 36 kA na 750 VDC, TM-DC zaštitna jedinica, 320 A struja, 3P;C40F3TM320D

Circuit breaker, ComPacT NSX400F DC, 36kA/750VDC, 3 poles, TM-DC trip unit 320A
-
Need to order

(Out of stock)

 
 
110.076,00

Schneider Electric prekidač ComPacT NSX320F DC, 36 kA na 750 VDC, TM-DC zaštitna jedinica, 320 A struja, 4P;C40F4TM320D

Circuit breaker, ComPacT NSX400F DC, 36kA/750VDC, 4 poles, TM-DC trip unit 320A
-
Need to order

(Out of stock)

 
 
153.636,00

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products
Complementary
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 250...570 A
Long-time protection delay adjustment type tr Adjustable
[tr] long-time protection delay adjustment range 15…400 s at 1.5 x Ir
0.35…11 s at 7.2 x Ir
0.5…16 s at 6 x Ir
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Adjustable
[tsd] Short-time protection delay adjustment range 0…0.4 s
Instantaneous protection pick-up adjustment type Ii Adjustable