Siemens ET 200SP, reversing starter F 0.9-3A HF; 3RK1308-0DC00-0CP0
Failsafe reversing starter High Feature; Electronic switching; electronic overload protection up to 1.1 kW / 400 V; Adjustment range 0.9 .. 3 A; PROFIenergy; option:...
Price on request
Failsafe reversing starter High Feature; Electronic switching; electronic overload protection up to 1.1 kW / 400 V; Adjustment range 0.9 .. 3 A; PROFIenergy; option: 3DI/LC module |
product brand name | SIMATIC |
product category | Motor starter |
product designation | Reversing starter |
product type designation | ET 200SP |
General technical data | |
trip class | CLASS OFF / 5 / 10 adjustable |
equipment variant according to IEC 60947-4-2 | 3 |
product function | Fail-safe reversing starter |
● on-site operation | Yes |
● intrinsic device protection | Yes |
● remote firmware update | Yes |
● for power supply reverse polarity protection | Yes |
insulation voltage rated value | 500 V |
degree of pollution | 2 |
overvoltage category | III |
surge voltage resistance rated value | 6 kV |
maximum permissible voltage for safe isolation | |
● between main and auxiliary circuit | 500 V |
shock resistance | 6g / 11 ms |
vibration resistance | 15 mm to 6 Hz; 2g to 500 Hz |
operating frequency maximum | 1 1/s |
mechanical service life (switching cycles) of the main contacts typical | 30 000 000 |
type of assignment | 1 |
utilization category | |
● according to IEC 60947-4-2 | AC-53a: 3 A: (8-0,7: 70-32) |
reference code according to IEC 81346-2 | Q |
Substance Prohibitance (Date) | 04/15/2016 |
product function | |
● direct start | Yes |
● reverse starting | Yes |
product component motor brake output | No |
product function short circuit protection | Yes |
design of short-circuit protection | fuse |
breaking capacity maximum short-circuit current (Icu) | |
● at 400 V rated value | 55 kA |
● at 500 V rated value | 55 kA |
● at 500 V according to UL 60947 rated value | 100 kA |
breaking capacity maximum short-circuit current (Icu) in the IT network | |
● at 400 V rated value | 55 kA |
● at 500 V rated value | 55 kA |
Electromagnetic compatibility | |
EMC emitted interference according to IEC 60947-1 | class A |
EMC immunity according to IEC 60947-1 | Class A |
conducted interference | |
● due to burst according to IEC 61000-4-4 | 3 kV |
● due to conductor-earth surge according to IEC 61000-4-5 | 4 kV |
● due to conductor-conductor surge according to IEC 61000-4-5 | 2 kV |
● due to high-frequency radiation according to IEC 61000-4-6 | Class A |
field-based interference according to IEC 61000-4-3 | 20 V/m |
electrostatic discharge according to IEC 61000-4-2 | 8 kV air discharge |
conducted HF interference emissions according to CISPR11 | Class A for industrial environment |
field-bound HF interference emission according to CISPR11 | Class A for industrial environment |
Safety related data | |
safety device type according to IEC 61508-2 | Type B |
B10d value | 3 400 000 |
Safety Integrity Level (SIL) according to IEC 61508 | 3 |
performance level (PL) according to EN ISO 13849-1 | e |
category according to EN ISO 13849-1 | 4 |
stop category according to EN 60204-1 | 0 |
diagnostics test interval by internal test function maximum | 600 s |
PFH according to IEC 61508 relating to SIL | 0.0000000036 1/h |
PFDavg with low demand rate according to IEC 61508 | 0.00000041 |
hardware fault tolerance according to IEC 61508 | 1 |
Similar products:
Siemens ET 200SP, D-O-L starter F 0.9-3A HF; 3RK1308-0CC00-0CP0
Fail-safe direct-on-line starter High Feature; Electronic switching; Electronic overload protection up to 1.1 kW / 400 V; Adjustment range 0.9 .. 3 A; PROFIenergy;
-
(Out of stock)
Price on request
Siemens ET 200SP, D-O-L starter F 2.8-9A HF; 3RK1308-0CD00-0CP0
Fail-safe direct-on-line starter High Feature; Electronic switching; Electronic overload protection up to 4 kW / 400 V; Adjustment range 2.8 .. 9 A; PROFIenergy;
-
(Out of stock)
Price on request
Siemens ET 200SP, D-O-L starter F 4.0-12A HF; 3RK1308-0CE00-0CP0
Fail-safe direct-on-line starter High Feature; Incl. fan (3RW4928-8VB00); Electronic switching; Electronic overload protection up to 5.5 kW / 400 V; Adjustment range
-
(Out of stock)
Price on request
Siemens ET 200SP,reversing starter 0.1 -0.4A HF; 3RK1308-0BA00-0CP0
Reversing starter High Feature; Electronic switching; Electronic overload protection up to 0.09 kW / 400 V; Adjustment range 0.1 .. 0.4 A; PROFIenergy; Option: 3DI/LC
-
(Out of stock)
Price on request
Siemens ET 200SP, reversing starter 0.3 - 1A HF; 3RK1308-0BB00-0CP0
Reversing starter High Feature; Electronic switching; Electronic overload protection up to 0.25 kW / 400 V; Adjustment range 0.3 .. 1 A; PROFIenergy; Option: 3DI/LC
-
(Out of stock)
Price on request
Siemens ET 200SP, reversing starter 0.9 - 3A HF; 3RK1308-0BC00-0CP0
Reversing starter High Feature; Electronic switching; Electronic overload protection up to 1.1 kW / 400 V; Adjustment range 0.9 .. 3 A; PROFIenergy; Option: 3DI/LC
-
(Out of stock)
Price on request