TeSys Deca - frame 4 Circuit-breakers to protect motors up to 115 A (55 kW / 400 V)
Search by features
TeSys Deca - frame 4 Circuit-breakers to protect motors up to 115 A (55 kW / 400 V)
Part of TeSys
Formerly named TeSys GV4. A compact, robust and innovative motor circuit breakers line.Schneider Electric Auxiliary contact, TeSys GV4, 690VAC, 1 NO/NC; GV4AE11
Auxiliary contact, TeSys GV4, 690VAC, 1 NO/NC; GV4AE11
-
(Out of stock)
3.203,00
Schneider Electric Rotary handle, TeSys GV4, direct, fixed, red, IP54; GV4ADN02
Rotary handle, TeSys GV4, direct, fixed, red, IP54; GV4ADN02
-
(Out of stock)
4.487,00
Schneider Electric Voltage release, TeSys GV4, MX coil, 220 to 240VAC 50Hz, 208 to 277VAC 60Hz; GV4AS287
Voltage release, TeSys GV4, MX coil, 220 to 240VAC 50Hz, 208 to 277VAC 60Hz; GV4AS287
-
(Out of stock)
8.492,00
Schneider Electric Motorni prekidač, TeSys GV4, 3P, 115A, Icu 25kA, termički magnetni, Everlink terminali; GV4PE115B
Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals; GV4PE115B
-
(Out of stock)
46.564,00
Schneider Electric Motorni prekidač, TeSys GV4, 3P, 115A, Icu 50kA, termo magnetni, Everlink terminali; GV4P115N
Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic, Everlink terminals GV4P115N
-
(Out of stock)
97.878,00
TeSys Deca - frame 4 Circuit-breakers to protect motors up to 115 A (55 kW / 400 V)
TeSys Deca Frame 4 is a cutting-edge technology that is both compact and robust. The electronic core of ref. GV4P gives great detection accuracy, as well as alarming and advanced protections for refs. GV4PEM and GV4PB. Magnetic, electronic thermal-magnetic, or electronic thermal magnetic versions with advanced protection.
Facts about TeSys Deca - Frame 4
** Covers motor protection from 0.25 to 55 kW at 415 V AC (from 0.8 to 115 A) all in one frame
** Available in three different breaking capacities:
- 25, 50, and 100 kA at 415 V AC IEC (15, 35, 65 kA at 480 V UL)
** Patented EverLink creep-compensating technology
- Spring-based system ensures a long-lasting connection
- Improves overheating leading to a trip
- Reduces risk during short circuits
** Ergonomic rotary handle for easy switching and controlling with clear trip indication. Other options include:
- Toggle
- Side
- Extended
** Available in three different versions:
** Type L: Magnetic short circuit protection to be used with an overload relay or a drive
** Type P: Magnetic short circuit and overload protection
- Electronic core for high-accuracy, wide settings, dual motor class 10/20
** Type PEM: Magnetic short circuit and overload protection with advanced settings and pre-alarming
- SDx side module available for alarming and fault differentiation (GV4 PEM)
** Available in three different breaking capacities:
- 25, 50, and 100 kA at 415 V AC IEC (15, 35, 65 kA at 480 V UL)
** Patented EverLink creep-compensating technology
- Spring-based system ensures a long-lasting connection
- Improves overheating leading to a trip
- Reduces risk during short circuits
** Ergonomic rotary handle for easy switching and controlling with clear trip indication. Other options include:
- Toggle
- Side
- Extended
** Available in three different versions:
** Type L: Magnetic short circuit protection to be used with an overload relay or a drive
** Type P: Magnetic short circuit and overload protection
- Electronic core for high-accuracy, wide settings, dual motor class 10/20
** Type PEM: Magnetic short circuit and overload protection with advanced settings and pre-alarming
- SDx side module available for alarming and fault differentiation (GV4 PEM)